Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
A completely automated algorithm to detect poor-quality electrocardiograms (ECGs) is described. The algorithm is based on both novel and previously published signal quality metrics, originally designed for intensive care monitoring. The algorithms have been adapted for use on short (5-10 s) single- and multi-lead ECGs. The metrics quantify spectral energy distribution, higher order moments and inter-channel and inter-algorithm agreement. Seven metrics were calculated for each channel (84 features in all) and presented to either a multi-layer perceptron artificial neural network or a support vector machine (SVM) for training on a multiple-annotator labelled and adjudicated training dataset. A single-lead version of the algorithm was also developed in a similar manner. Data were drawn from the PhysioNet Challenge 2011 dataset where binary labels were available, on 1500 12-lead ECGs indicating whether the entire recording was acceptable or unacceptable for clinical interpretation. We re-annotated all the leads in both the training set (1000 labelled ECGs) and test dataset (500 12-lead ECGs where labels were not publicly available) using two independent annotators, and a third for adjudication of differences. We found that low-quality data accounted for only 16% of the ECG leads. To balance the classes (between high and low quality), we created extra noisy data samples by adding noise from PhysioNet's noise stress test database to some of the clean 12-lead ECGs. No data were shared between training and test sets. A classification accuracy of 98% on the training data and 97% on the test data were achieved. Upon inspection, incorrectly classified data were found to be borderline cases which could be classified either way. If these cases were more consistently labelled, we expect our approach to achieve an accuracy closer to 100%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ambulatory data measured with wearable sensors, mobile phones, and surveys tend to be noisy.”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Pattern Recognition and Machine Learning
(2006) · doi:10.1007/978-0-387-45528-0 · Cited by 9,824
The Levenberg-Marquardt algorithm: Implementation and theory
Moré, J. J. (1978) · Lecture Notes in Mathematics · doi:10.1007/bfb0067700 · Cited by 5,773
A Practical Guide to Support Vector Classication
Hsu, C., Chang, C.-C., & Lin, C. (2008) · Cited by 5,083
Pattern Recognition and Machine Learning
Neal, R. M. (2007) · Technometrics · doi:10.1198/tech.2007.s518 · Cited by 4,571
A User’s Guide to Support Vector Machines
Ben-Hur, A., & Weston, J. (2010) · Methods in Molecular Biology · doi:10.1007/978-1-60327-241-4_13 · Cited by 822
Advanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
Self-citationLi, Q., Mark, R. G., & Clifford, G. D. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/1/002 · Cited by 426
Self-citation
Cited by
Items 301–352 of 352
Liu, J., Miao, H., Liu, Z., Fan, X., Chang, S., Sun, G., Xu, L., & Li, H. (2026) · Asian Heart Journal · doi:10.1097/ah9.0000000000000045
Detección de ataques epilépticos a partir de señales fisiológicas
Carrizosa‐Botero, S. (2019) · EIA University Library (EIA University)
Application of Meta Learning in Quality Assessment of Wearable Electrocardiogram Recordings
Herráiz, Á. H., Martínez‐Rodrigo, A., Guimarães, M., Carneiro, D. R., Rieta, J. J., & Alcaraz, R. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-62520-6_20
Quality Control in ECG-based Atrial Fibrillation Screening
Halvaei, H. (2023) · Lund University Publications (Lund University)
Neto, A. C. D. C. (2025) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.45.2025.tde-01092025-211443
Tensor-gebaseerde analyse van ECG signalen in plotse hartdood
Goovaerts, G. (2018) · Lirias
Farrokhi, S., Sequeira, L., Burke, S. L., Dargie, W., & Poellabauer, C. (2026) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2026.3747683
Wearable and Invisible ECG Quality and Usability Assessment in Cockpit Monitoring
Pinnelli, M., Calado, A. S. A., Fernandes, T. F. R., André, P. S. D. B., Schena, E., Massaroni, C., & Silva, H. (2026) · Biosensors · doi:10.3390/bios16090486
Iovino, M. (2026) · Nova Science Publishers (Nova Science Publishers, Inc.)
Masked Autoencoders that Feel the Heart: Unveiling Simplicity Bias for ECG AnalysesPreprint
Xu, H., Gao, H., Li, Y., Wei, X.-S., & Liu, C. (2025) · arXiv · doi:10.48550/arxiv.2506.22495
Image processing approach to baseline drift removal from electrocardiogram signals
Petrović, M., & Petrovic, B. D. (2017) · IEEE Life Sciences Conference (LSC) · doi:10.1109/lsc.2017.8268181
Single-lead ECG biomarkers for cardiovascular and mortality risk prediction
Attali, L., Solewicz, Y. A., Biton, S. B., Hamami, H., Zvuloni, E., Green, I., Laufer, I., Laguna, P., Martín-Yebra, A., Martínez, J. P., et al. (2026) · Physiological Measurement · doi:10.1088/1361-6579/aea9ec
Self-citationChromik, J., Klopfenstein, S. A. I., Pfitzner, B., Sinno, Z.-C., Arnrich, B., Balzer, F., & Poncette, A.-S. (2022) · doi:10.3389/fdgth.2022.843747.s001
Katasonov, D. N. (2016) · International Scientific-Technical Conference on Actual Problems of Electronic Instrument Engineering (APEIE) · doi:10.1109/apeie.2016.7806985
Katasonov, D. N. (2016) · International Scientific-Technical Conference on Actual Problems of Electronic Instrument Engineering (APEIE) · doi:10.1109/apeie.2016.7807040
Thesis Pre-Processing ECG & Respiratory Signals for Detection of Stress
Kuruoğlu, T., & Kinaci, E. (2020) · Research Repository (Delft University of Technology)
Spanik, J., Králiková, Ľ., Janoušek, L., & Babušiak, B. (2026) · Measurement · doi:10.1016/j.measurement.2026.123228
Saberi, S., Karimi, A., Zarafshan, F., & Torkestani, J. A. (2026) · Research Square · doi:10.21203/rs.3.rs-10928516/v1
Smallwood, C. D., Gouldstone, A., & Arnold, J. H. (2020) · Research Square · doi:10.21203/rs.2.20959/v1
Ma, F. (2018) · Research Repository (Delft University of Technology)
TR-index: Semantic Characterization for Non-invasive Fetal ECG Signal Quality Assessment
Zhong, W., & Du, W. (2021) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm52615.2021.9669718
Detection of ECG Noise Using Optimized Pan-Tompkins Algorithm Combined with Squeeze-UNet
Nguyen, X.-D., Bui, A.-D., & Tran, H.-D. (2025) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-90194-2_2
Er, F., & Çifçi, M. A. (2026) · Sensors · doi:10.3390/s26227181
Nathan, L. P. A., Hemamalini, R. R., Jeremiah, R. J. R., Ettappan, M., Partheeban, P., & Ponnusamy, R. (2023) · International Conference on Data Science, Agents & Artificial Intelligence (ICDSAAI) · doi:10.1109/icdsaai59313.2023.10452544
On applying multi-scale entropy to quality assessment of ECG collected via mobile phone
Zhang, Y., Shoushui, W., Long, Y., & Chengyu, L. (2015) · Chinese Control Conference (CCC) · doi:10.1109/chicc.2015.7260377
Detección de arritmias mediante parámetros de calidad de señal y estadísticos
de Cabrera, A., & Alberto, C. (2017) · Deposito de Investigacion Universidad de Sevilla (University of Seville)
Zhang, Y., liu, H., Wei, S., & Liu, C. (2017) · Preprints.org · doi:10.20944/preprints201711.0060.v1
Modelling and Quality Assessment of Atrial Fibrillatory Waves
Henriksson, M. (2019) · Lund University Publications (Lund University)
Signal Quality Features in Dynamic ECGs
Li, Y., Liu, C., Zhang, Y., & Li, J. (2020) · Springer eBooks · doi:10.1007/978-981-15-3824-7_4
Sarkar, S. M., & Samanta, P. (2023) · Journal of Electrical and Electronic Engineering · doi:10.11648/j.jeee.20231104.12
An attention-based Bi-stream deep learning architecture for ECG arrhythmia classification
Rayasam, K. C., Kar, S. K., & Das, S. K. (2026) · Signal Image and Video Processing · doi:10.1007/s11760-026-05822-4
Billeci, L., Bachi, L., Podrecca, C., Varanini, M., & Cincione, P. (2024) · Computing in cardiology · doi:10.22489/cinc.2024.042
Bachi, L., Varanini, M., Costi, M., Lombardi, D., & Billeci, L. (2024) · Computing in cardiology · doi:10.22489/cinc.2024.287
Karmakar, D., Mendis, L., Keenan, E., Palaniswami, M. S., Makalic, E., & Brownfoot, F. (2026) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.71416
A fast signal quality assessment algorithm applied to a \ncontactless electrocardiogram system
Targino Lins, L. (2021) · Espace ÉTS (ETS)
Análise de ECG no contexto de telemonitorização em insuficiência cardíaca
Pereira, L. V. C. (2015) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
A Lightweight Multi-Scale Convolutional Neural Network-Based Method for ECG Quality Assessment
Chen, H., Li, Y., & Gao, N. (2025) · IEEE International Conference on Electronic Measurement & Instruments · doi:10.1109/icemi66537.2025.11306527
Gajdzik, F., Kimbar, M., & Krowicki, P. (2026) · Acta of Bioengineering and Biomechanics · doi:10.37190/abb/231067
Silva, A. D. S., Correia, M. V., da Costa, A. G., Cerqueira, R. J., & Silva, H. (2026) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan15030035
Hybrid Hard–Soft Clustering For Outlier Detection: Development of the HS-COS Framework
Trivedi, R., & Srivastava, N. (2026) · Global Journal of Mathematics and Statistics · doi:10.61424/gjms.v3i1.828
Sumber, S., Setioningsih, E. D., Triwiyanto, T., Nashichah, R., & Athavale, V. A. (2026) · Journal of Applied Engineering and Technological Science (JAETS) · doi:10.37385/jaets.v7i2.9426
Jang, H.-W., Kang, S.-M., & Choi, S.-W. (2026) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-026-2210-9
Metody detekce arytmií z neinvazivního plodového elektrokardiogramu
Mikolasova, M. P. (2026) · DSpace VŠB-TUO (VŠB-TUO)
A system for assessing TMG signal validity
Skočir, A. (2026) · Repository of the University of Ljubljana (University of Ljubljana)
Nathan, L. P. A., Hemamalini, R. R., Jeremiah, R. J. R., & Partheeban, P. (2026) · Next research. · doi:10.1016/j.nexres.2026.102560
Guzmán-García, C., Martini, C., Gaibazzi, N., Quadrelli, M., Morra, A., Costantino, C., Guaricci, A., Aversano, L., Pecori, R., Mordonini, M., et al. (2026) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2026.109688
Robust Multi-Task Semi-Supervised Network for Fine-Grained Wearable ECG Segmentation
Ma, S., Lei, J., Wang, Y., & Qi, W. (2026) · IEEE Smart World Congress (SWC) · doi:10.1109/swc69865.2026.11764050
Georgieva-Tsaneva, G. N., & Tsanev, Y.-A. (2026) · International Conference on Software, Telecommunications and Computer Networks (SoftCOM) · doi:10.23919/softcom70073.2026.11761634
Arora, S. R., Kumar, S., Sharma, N., & Singh, B. (2026) · doi:10.1109/chandicon70877.2026.11767553
Lu, A., Cho, S., Meng, Z., Yan, R., Kataria, S., Castle, L., Westerman, S. B., Hu, X., & Xiao, R. (2026) · Machine learning for signal processing ... · doi:10.1109/mlsp68619.2026.11772589
Machine Learning-Based ECG Signal Quality Assessment in Portable Cardiac Monitoring Systems
Bekbay, A., Bigaliyeva, Z., Bayanbay, N., Baityrganova, V., Sagyndikova, A., & Bazarbay, L. (2026) · Procedia Computer Science · doi:10.1016/j.procs.2026.10.527
Metadata
- Authors
- Clifford, G. D., Behar, J., Li, Q., & Rezek, I.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-08-17
- Volume
- 33
- Issue
- 9
- Pages
- 1419-1433
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2122930900
- Cited by
- 292
- References
- 28
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.