Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
A completely automated algorithm to detect poor-quality electrocardiograms (ECGs) is described. The algorithm is based on both novel and previously published signal quality metrics, originally designed for intensive care monitoring. The algorithms have been adapted for use on short (5-10 s) single- and multi-lead ECGs. The metrics quantify spectral energy distribution, higher order moments and inter-channel and inter-algorithm agreement. Seven metrics were calculated for each channel (84 features in all) and presented to either a multi-layer perceptron artificial neural network or a support vector machine (SVM) for training on a multiple-annotator labelled and adjudicated training dataset. A single-lead version of the algorithm was also developed in a similar manner. Data were drawn from the PhysioNet Challenge 2011 dataset where binary labels were available, on 1500 12-lead ECGs indicating whether the entire recording was acceptable or unacceptable for clinical interpretation. We re-annotated all the leads in both the training set (1000 labelled ECGs) and test dataset (500 12-lead ECGs where labels were not publicly available) using two independent annotators, and a third for adjudication of differences. We found that low-quality data accounted for only 16% of the ECG leads. To balance the classes (between high and low quality), we created extra noisy data samples by adding noise from PhysioNet's noise stress test database to some of the clean 12-lead ECGs. No data were shared between training and test sets. A classification accuracy of 98% on the training data and 97% on the test data were achieved. Upon inspection, incorrectly classified data were found to be borderline cases which could be classified either way. If these cases were more consistently labelled, we expect our approach to achieve an accuracy closer to 100%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ambulatory data measured with wearable sensors, mobile phones, and surveys tend to be noisy.”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Pattern Recognition and Machine Learning
(2006) · doi:10.1007/978-0-387-45528-0 · Cited by 9,824
The Levenberg-Marquardt algorithm: Implementation and theory
Moré, J. J. (1978) · Lecture Notes in Mathematics · doi:10.1007/bfb0067700 · Cited by 5,773
A Practical Guide to Support Vector Classication
Hsu, C., Chang, C.-C., & Lin, C. (2008) · Cited by 5,083
Pattern Recognition and Machine Learning
Neal, R. M. (2007) · Technometrics · doi:10.1198/tech.2007.s518 · Cited by 4,571
A User’s Guide to Support Vector Machines
Ben-Hur, A., & Weston, J. (2010) · Methods in Molecular Biology · doi:10.1007/978-1-60327-241-4_13 · Cited by 822
Advanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
Self-citationLi, Q., Mark, R. G., & Clifford, G. D. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/1/002 · Cited by 426
Self-citation
Cited by
Items 101–200 of 352
Machine Learning Models for Multidimensional Clinical Data
Orphanidou, C., & Wong, D. (2017) · Scalable computing and communications · doi:10.1007/978-3-319-58280-1_8 · Cited by 26
Lueken, M., Gramlich, M., Leonhardt, S. K., Marx, N., & Zink, M. D. (2023) · Sensors · doi:10.3390/s23125618 · Cited by 25
Extraction of clinical information from the non-invasive fetal electrocardiogramPreprint
Behar, J. A. (2014) · arXiv · doi:10.48550/arxiv.1606.01093 · Cited by 25
Self-citationDynamic signal quality index for electrocardiograms
Yaghmaie, N., Maddah-Ali, M. A., Jelinek, H. F., & Marzbanrad, F. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aadf02 · Cited by 25
Zhang, X., & Ding, Q. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.02.003 · Cited by 24
Zhang, Q., Zhou, D., & Zeng, X. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/11/1945 · Cited by 24
Fetal ECG extraction from time-varying and low-rank noninvasive maternal abdominal recordings
Jamshidian-Tehrani, F., & Sameni, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aaef5d · Cited by 24
A Review on Atrial Fibrillation Detection From Ambulatory ECG
Ma, C., Xiao, Z., Zhao, L., Biton, S. B., Behar, J. A., Long, X., Vullings, R., Aarts, R. M., Li, J., & Liu, C. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3321792 · Cited by 23
Self-citationDore, H., Avilés‐Espinosa, R., Luo, Z., Anton, O., Rabe, H., & Rendón-Morales, E. (2021) · Sensors · doi:10.3390/s21030999 · Cited by 23
Wander, J. D., & Morris, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/12/2543 · Cited by 22
Bläsing, D., Buder, A., Reiser, J. E., Nisser, M., Derlien, S., & Vollmer, M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0274994 · Cited by 22
Stretchable Ag/AgCl Nanowire Dry Electrodes for High-Quality Multimodal Bioelectronic Sensing
Wang, T., Yao, S., Shao, L., & Zhu, Y. (2024) · Sensors · doi:10.3390/s24206670 · Cited by 22
Gold, N., Herry, C. L., Wang, X., & Frasch, M. G. (2021) · Frontiers in Pediatrics · doi:10.3389/fped.2021.593889 · Cited by 22
Signal quality classification of mobile phone-recorded phonocardiogram signals
Springer, D., Brennan, T. J., Zuhlke, L. J., Abdelrahman, H. Y., Ntusi, N., Clifford, G. D., Mayosi, B. M., & Tarassenko, L. (2014) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2014.6853814 · Cited by 22
Self-citationWan, C., Gao, S., Shang, X., Wu, Z., Li, T., Ling, W., Zhou, M., Huo, W., Guo, Y. F., & Huang, X. L. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100904 · Cited by 21
Robust cardiac event change detection method for long‐term healthcare monitoring applications
Satija, U., Ramkumar, B., & Manikandan, M. S. (2016) · Healthcare Technology Letters · doi:10.1049/htl.2015.0062 · Cited by 21
Le, K., Servati, A., Soltanian, S., Servati, P., & Ko, F. (2021) · Frontiers in Electronics · doi:10.3389/felec.2021.685264 · Cited by 21
Basile, I., & Sannino, G. (2024) · Results in Engineering · doi:10.1016/j.rineng.2024.103681 · Cited by 20
Binary Classifiers for Data Integrity Detection in Wearable IoT Edge Devices
John, A., Panicker, R. C., Cardiff, B., Lian, Y., & John, D. (2020) · IEEE Open Journal of Circuits and Systems · doi:10.1109/ojcas.2020.3009520 · Cited by 20
Xie, J., Li, P., Liang, W., Gong, Y., Zuo, F., Wang, J., Yin, C., & Li, Y. (2021) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-021-02425-8 · Cited by 20
A real-time quality monitoring system for optimal recording of 12-lead resting ECG
Jekova, I. I., Krasteva, V., Leber, R., Schmid, R., Twerenbold, R., Reichlin, T., Mueller, C. E., & Abächerli, R. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.01.009 · Cited by 20
Measurement of the conductive fabric contact impedance for bioelectrical signal acquisition purposes
Kralikova, I., Babušiak, B., & Šmondrk, M. (2023) · Measurement · doi:10.1016/j.measurement.2023.113005 · Cited by 19
Smallwood, C. D., Walsh, B. K., Arnold, J. H., & Gouldstone, A. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003001 · Cited by 19
Signal quality indices evaluation for robust ECG signal quality assessment systems
Kuetche, F., Alexendre, N., Pascal, N. E., Welba, C., & Thierry, S. (2023) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ace9e0 · Cited by 19
Felici, M., Nardelli, M., Lanatà, A., Sgorbini, M., Scilingo, E. P., & Baragli, P. (2020) · Equine Veterinary Journal · doi:10.1111/evj.13296 · Cited by 18
Castro, I. D., Mercuri, M., Torfs, T., Lorato, I. R., Puers, R., & Hoof, C. A. V. (2018) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2018.2802639 · Cited by 18
Smartware electrodes for ECG measurements : Design, evaluation and signal processing
Rattfält, L. (2013) · Linköping University Electronic Press eBooks · doi:10.3384/diss.diva-100134 · Cited by 17
Online ECG quality assessment for context-aware wireless body area networks
Tobón, D. P., & Falk, T. H. (2015) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2015.7129341 · Cited by 17
Finding representative electrocardiogram beat morphologies with CUR
Hendryx, E. P., Rivière, B. M., Sorensen, D. C., & Rusin, C. G. (2017) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2017.12.003 · Cited by 17
An Overview of Signal Quality Indices on Dynamic ECG Signal Quality Assessment
Liu, F., Wei, S., Fei, L., Jiang, X., & Liu, C. (2020) · Springer eBooks · doi:10.1007/978-981-15-3824-7_3 · Cited by 17
Signal Quality Assessment of Compressively Sensed Electrocardiogram
Abdelazez, M., Rajan, S., & Chan, A. D. C. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3170047 · Cited by 17
An Open-Access Arrhythmia Database of Wearable Electrocardiogram
Shen, Q., Gao, H., Li, Y., Sun, Q. Y., Chen, M., Li, J., & Liu, C. (2020) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-020-00554-3 · Cited by 17
Xiao, Z., Xing, Y., Li, Y., Yang, C., Li, J., & Liu, C. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3186709 · Cited by 17
Assessment of Fetal Development Using Cardiac Valve Intervals
Marzbanrad, F., Khandoker, A. H., Kimura, Y., Palaniswami, M. S., & Clifford, G. D. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00313 · Cited by 16
Self-citationRobust heart rate variability analysis by generalized entropy minimization
Vecchia, D. L., Camponovo, L., & Ferrari, D. (2014) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2014.09.001 · Cited by 16
Low-complexity detection and classification of ECG noises for automated ECG analysis system
Satija, U., Ramkumar, B., & Manikandan, M. S. (2016) · International Conference on Signal Processing and Communications (SPCOM) · doi:10.1109/spcom.2016.7746621 · Cited by 16
Opening the envelope: Efficient envelope-based PPG denoising algorithm
Bradley, G. R. E., & Kyriacou, P. A. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105693 · Cited by 16
Detection of Noise Type in Electrocardiogram
Abdelazez, M., Rajan, S., & Chan, A. D. C. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438664 · Cited by 16
Robust detection of heartbeats using association models from blood pressure and EEG signals
Jeon, T., Yu, J., Pedrycz, W., Jeon, M., Lee, B., & Lee, B. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0122-0 · Cited by 16
A Smart Textile Band Achieves High-Quality Electrocardiograms in Unrestrained Horses
McCrae, P., Spong, H., Rutherford, A.-A., Osborne, V. R., Mahnam, A., & Pearson, W. (2022) · Animals · doi:10.3390/ani12233254 · Cited by 15
Baldazzi, G., Sulas, E., Vullings, R., Urru, M., Tumbarello, R., Raffo, L., & Pani, D. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1059119 · Cited by 15
Non-invasive Fetal ECG Signal Quality Assessment based on Unsupervised Learning Approach
Shi, X., Yamamoto, K., Ohtsuki, T. O., Matsui, Y., & Owada, K. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9870908 · Cited by 15
Preliminary Analysis of a Wireless and Wearable Electronic-Textile EASI-Based Electrocardiogram
Teferra, M. N., Hobbs, D., Clark, R. A., & Reynolds, K. J. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.806726 · Cited by 15
Lu, L., Yang, K. Y., Kong, X., Yang, R., & Wang, Y. (2018) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2018.2836931 · Cited by 14
Heart Rhythm Classification using Short-term ECG Atrial and Ventricular Activity Analysis
Yazdani, S., Laub, P., Luca, A., & Vésin, J.-M. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.067-120 · Cited by 14
Pelter, M. M., Carey, M. G., Al‐Zaiti, S. S., Zègre‐Hemsey, J. K., Sommargren, C. E., Isola, L., Prasad, P. A., MORTARA, D. W., & Badilini, F. (2023) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.13054 · Cited by 13
Identification of Transient Noise to Reduce False Detections in Screening for Atrial Fibrillation
Halvaei, H., Svennberg, E., Sörnmo, L., & Stridh, M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.672875 · Cited by 13
Li, J., & Wang, Q. (2022) · Expert Systems with Applications · doi:10.1016/j.eswa.2022.119429 · Cited by 13
Liu, Y., Chen, J., Fang, B., Chen, Y., & Lv, Z. (2022) · IEEE Transactions on Network Science and Engineering · doi:10.1109/tnse.2022.3184523 · Cited by 13
Keskes, N., Fakhfakh, S., Kanoun, O., & Derbel, N. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103686 · Cited by 13
Quality Assessment for the Electrocardiogram (ECG)
Orphanidou, C. (2017) · SpringerBriefs in bioengineering · doi:10.1007/978-3-319-68415-4_2 · Cited by 13
Marzbanrad, F., Kimura, Y., Endo, M., Palaniswami, M. S., & Khandoker, A. H. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7408662 · Cited by 13
Mobile Health Revolution in Healthcare: Are We Ready?
Claes, S. J., Berckmans, D., Geris, L., Myin‐Germeys, I., Audenhove, C. V., Diest, I. V., Hoof, C. A. V., Hoyweghen, I. V., Huffel, S. V., & Vrieze, E. (2019) · Lirias · Cited by 12
Zhu, W., Qiu, L., Cai, W., Yu, J., Li, D., Li, W., Zhong, J., Wang, Y., & Wang, L. (2021) · Physiological Measurement · doi:10.1088/1361-6579/abf9f4 · Cited by 12
Data Quality Assessment of Capacitively-coupled ECG Signals
Castro, I. D., Varon, C., Moeyersons, J., Gómez, A. V., Morales, J., Deviaene, M., Torfs, T., Huffel, S. V., Puers, R., & Hoof, C. V. (2019) · Computing in cardiology · doi:10.22489/cinc.2019.376 · Cited by 12
Unsupervised Learning-Based Non-Invasive Fetal ECG Muti-Level Signal Quality Assessment
Shi, X., Yamamoto, K., Ohtsuki, T. O., Matsui, Y., & Owada, K. (2023) · Bioengineering · doi:10.3390/bioengineering10010066 · Cited by 12
Bayesian voting of multiple annotators for improved QT interval estimation
Zhu, T., Johnson, A. E. W., Behar, J. A., & Clifford, G. D. (2013) · Computing in cardiology · Cited by 12
Self-citationContinuous-Valued Annotations Aggregation for Heart Rate Detection
Xie, Y., Li, J., Zhu, T., & Liu, C. (2019) · IEEE Access · doi:10.1109/access.2019.2902619 · Cited by 12
A scalable mHealth system for noncommunicable disease management
Clifford, G. D., Arteta, C., Zhu, T., Pimentel, M., Santos, M., Domingos, J., Maraci, M. A., Behar, J. A., & Oster, J. (2014) · IEEE Global Humanitarian Technology Conference (GHTC) · doi:10.1109/ghtc.2014.6970259 · Cited by 12
Self-citationWang, Z., Ma, C., Zhang, Y., Li, Y., Zhao, L., Li, J., & Liu, C. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106723 · Cited by 11
A Portable ECG Patch Monitor Based on Flexible Non-hydrogel Electrode
Chu, H., Yang, C., Xing, Y., Li, J., & Liu, C. (2022) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-022-00709-4 · Cited by 11
Multi-task cascaded assessment of signal quality for long-term single-lead ECG monitoring
Liu, S., Zhong, G., He, J., & Yang, C. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104674 · Cited by 11
Exploring Key Factors on Capacitive ECG Signal Quality Under Practical Considerations
Cui, R., Zheng, X., Wang, K., Chen, H., Chen, W., Chen, C., & Luo, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3470044 · Cited by 11
Huang, X., Zhang, F., Fan, H., Chang, H., Zhou, B., & Li, Z. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.107928 · Cited by 11
Smallwood, C. D., Walsh, B. K., Arnold, J. H., & Gouldstone, A. (2019) · Respiratory Care · doi:10.4187/respcare.06707 · Cited by 11
Sörnmo, L., Alcaraz, R., Laguna, P., & Rieta, J. J. (2018) · Series in bioengineering · doi:10.1007/978-3-319-68515-1_6 · Cited by 11
ECG quality assessment based on multi-feature fusion
Xia, Y., & Jia, H. (2017) · International Conference on Natural Computation, Fuzzy Systems and Knowledge Discovery (ICNC-FSKD) · doi:10.1109/fskd.2017.8393352 · Cited by 11
Cloud-Based Artificial Intelligence System for Large-Scale Arrhythmia Screening
Tseng, C.-H., Lin, C., Chang, H., Liu, C.-C., Serafico, B. M. F., Wu, L.-C., Lin, C., Hsu, T., Huang, C., & Lo, M. (2019) · Computer · doi:10.1109/mc.2019.2933195 · Cited by 10
Chen, W. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_1 · Cited by 10
Kuetche, F., Alexendre, N., Pascal, N. E., & Thierry, S. (2023) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2023.101375 · Cited by 10
An Optimized Signal Quality Assessment Method for Noncontact Capacitive ECG
Jiang, Y., Xiao, Z., Zhang, Y., Ma, C., Yang, C., Wei-ming, J., Li, J., & Liu, C. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3533644 · Cited by 10
Kumar, A., Mehla, V. K., Tomar, H., Kumar, M., & Komaragiri, R. (2020) · IEEE International Symposium on Smart Electronic Systems (iSES) · doi:10.1109/ises50453.2020.00044 · Cited by 10
Paliakaitė, B., Petrėnas, A., Henriksson, M., Skibarkienė, J., Kubilius, R., Sörnmo, L., & Marozas, V. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.08.027 · Cited by 10
Automatic Classification of ECG Data Quality for Each Channel
Wang, Q., Mao, Y. W., Ren, L., Li, Z., & Liu, H. (2020) · IEEE Access · doi:10.1109/access.2020.3034449 · Cited by 10
An Approximate Binary Classifier for Data Integrity Assessment in IoT Sensors
John, A., Ullah, S., Kumar, A. S., Cardiff, B., & John, D. (2020) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs49266.2020.9294859 · Cited by 10
A Deep and Interpretable Learning Approach for Long-Term ECG Clinical Noise Classification
Holgado–Cuadrado, R., Plaza–Seco, C., Lovisolo, L., & Blanco–Velasco, M. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3454545 · Cited by 9
Herráiz, Á. H., Martínez‐Rodrigo, A., Carneiro, D. R., Bertomeu‐González, V., Rieta, J. J., & Alcaraz, R. (2023) · IEEE Access · doi:10.1109/access.2023.3317793 · Cited by 9
Chocron, A., Efraim, R., Mandel, F., Rueschman, M., Palmius, N., Penzel, T., Elbaz, M., & Behar, J. A. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abb8bf · Cited by 9
Self-citationAn intelligent cardiac health monitoring and review system
Zhu, T., Oster, J., Osipov, M., Clifford, G. D., Clifton, D. A., & Papastylianou, T. (2014) · Appropriate Healthcare Technologies for Low Resource Settings (AHT) · doi:10.1049/cp.2014.0785 · Cited by 9
Self-citationPelter, M. M., MORTARA, D. W., & Badilini, F. (2021) · Hearts · doi:10.3390/hearts2040036 · Cited by 8
Zhu, W., Zheng, L., Cheng, A., Qiu, L., Chen, Y., & Wang, L. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104804 · Cited by 8
Lazić, I., Pernice, R., Lončar-Turukalo, T., Mijatović, G., & Faes, L. (2021) · Entropy · doi:10.3390/e23060698 · Cited by 8
Activity Type Effects Signal Quality in Electrocardiogram Devices
Lindsey, B., Snyder, S. J., Zhou, Y., Shim, J. K., Hahn, J., Evans, W., & Martin, J. R. (2025) · Sensors · doi:10.3390/s25165186 · Cited by 8
An expert electrocardiogram quality evaluation algorithm based on signal mobility factors
Naseri, H., Homaeinezhad, M. R., & Pourkhajeh, H. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.794868 · Cited by 8
From sleep medicine to medicine during sleep: a new paradigm
Behar, J. A. (2019) · SLEEP · doi:10.1093/sleep/zsz279 · Cited by 7
Self-citationLi, H., Zhang, Y., Han, J., Yan, Y., Liu, Y., & Yang, H. (2022) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm55620.2022.9995362 · Cited by 7
Idrobo-Ávila, E., Correa, H. L., Vargas-Cañas, R., Muñoz-Bolaños, F., & van Noorden, L. (2021) · Heliyon · doi:10.1016/j.heliyon.2021.e06257 · Cited by 7
Quality Indexes of the ECG Signal Transmitted Using Optical Wireless Link
Chehbani, A., Sahuguede, S., Julien‐Vergonjanne, A., & Bernard, O. (2023) · Sensors · doi:10.3390/s23094522 · Cited by 7
Quantifying the Suitability of Biosignals Acquired During Surgery for Multimodal Analysis
Idrobo-Ávila, E., Bognár, G., Krefting, D., Penzel, T., Kovács, P., & Spicher, N. (2024) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2024.3379733 · Cited by 7
Supervised SVM Transfer Learning for Modality-Specific Artefact Detection in ECG
Moeyersons, J., Morales, J., Villa, A., Castro, I. D., Testelmans, D., Buyse, B., Hoof, C. A. V., Willems, R., Huffel, S. V., & Varon, C. (2021) · Sensors · doi:10.3390/s21020662 · Cited by 6
Robust T-End Detection via T-End Signal Quality Index and Optimal Shrinkage
Su, P.-C., Soliman, E. Z., & Wu, H. (2020) · Sensors · doi:10.3390/s20247052 · Cited by 6
Signal quality indices for state space electrophysiological signal processing and vice versa
Oster, J., & Clifford, G. D. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139941433.016 · Cited by 6
Self-citationA Bayesian Fusion Model for Heart Rate Annotations
Di, J., Li, J., & Liu, C. (2020) · International Conference on Sensing, Measurement & Data Analytics in the era of Artificial Intelligence (ICSMD) · doi:10.1109/icsmd50554.2020.9261732 · Cited by 6
A signal quality assessment method for fetal QRS complexes detection
Zhong, W., Li, M., & Du, W. (2023) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2023344 · Cited by 6
Llamedo, M., & Martínez, J. P. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab553a · Cited by 6
Signal Quality Auditing for Time-series DataPreprint
Gao, C., Gisolfi, N., & Dubrawski, A. W. (2024) · arXiv · doi:10.48550/arxiv.2402.00803 · Cited by 6
Determining the input impedance of ECG amplifiers using accurate electrode modelling
Maji, S., & Burke, M. J. (2020) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab6ed0 · Cited by 6
Kuetche, F., Alexendre, N., Pascal, N. E., & Thierry, S. (2025) · Engineering Research Express · doi:10.1088/2631-8695/adede3 · Cited by 6
Zhang, Y., Wei, S., Zhang, L., & Liu, C. (2016) · International Conference on Natural Computation, Fuzzy Systems and Knowledge Discovery (ICNC-FSKD) · doi:10.1109/fskd.2016.7603309 · Cited by 6
Artificial Intelligence of Things for Early Detection of Cardiac Diseases
Thomas, T., & Kurian, A. N. (2022) · Springer eBooks · doi:10.1007/978-3-030-80928-7_4 · Cited by 5
Metadata
- Authors
- Clifford, G. D., Behar, J., Li, Q., & Rezek, I.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-08-17
- Volume
- 33
- Issue
- 9
- Pages
- 1419-1433
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2122930900
- Cited by
- 292
- References
- 28
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.