The DOI matches its Crossref record; 29 of the 31 references it cites were found in a registry or an index.
Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
Open accessAbstract
In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphology due to changes in heart rate, cardiac output, sensor type and hardware or software pre-processing requirements. Moreover, considerable inter-individual and sensor-location variability exists. Simple template matching methods are therefore inappropriate, and a patient-specific adaptive initialization is therefore required. We introduce dynamic time warping to stretch each beat to match a running template and combine it with several other features related to signal quality, including correlation and the percentage of the beat that appeared to be clipped. The features were then presented to a multi-layer perceptron neural network to learn the relationships between the parameters in the presence of good- and bad-quality pulses. An expert-labeled database of 1055 segments of PPG, each 6 s long, recorded from 104 separate critical care admissions during both normal and verified arrhythmic events, was used to train and test our algorithms. An accuracy of 97.5% on the training set and 95.2% on test set was found. The algorithm could be deployed as a stand-alone signal quality assessment algorithm for vetting the clinical utility of PPG traces or any similar quasi-periodic signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Some other examples are mentioned here: Bayesian network for classifying stress level [26,39] or for predicting patient's state [72], Fuzzy state machine for estimating the health status to provide alerts [68], logistic regression models [42] and association rules [41] to predict stress level and hospitalization of hemodialysis patients, respectively.”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [72]
In the citing paper
“Several approaches have been proposed, including statistical analysis of pulse wave shape [56], assessing the level of perfusion through the perfusion index (the ratio of the amplitude of the pulsatile component of the PPG to its baseline) [56], assessing the similarity of successive pulse wave shapes using template matching [86] or dynamic time warping [87], and deep learning [88].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [87]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Faires, J. D. (1978) · Cited by 6,711
The Levenberg-Marquardt algorithm: Implementation and theory
Morè, J. J. (1978) · Lecture notes in mathematics · doi:10.1007/bfb0067700 · Cited by 5,796
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Exact indexing of dynamic time warping
Keogh, E., & Ratanamahatana, C. A. (2004) · Knowledge and Information Systems · doi:10.1007/s10115-004-0154-9 · Cited by 1,962
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400
An open-source algorithm to detect onset of arterial blood pressure pulses
Zong, W., Heldt, T., Moody, G. B., & Mark, R. G. (2003) · Computers in cardiology · doi:10.1109/cic.2003.1291140 · Cited by 326
Saeed, M., Lieu, C., RABER, G., & Mark, R. G. (2003) · Computers in cardiology · doi:10.1109/cic.2002.1166854 · Cited by 273
Signal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166
Signal processing methods for heart rate variability
Clifford, G. D. (2002) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-noa0mqzyn · Cited by 131
Self-citation
Research works printed but not linked: 14
- Addison P S Watson J N, 2010
- Clifford G D, 2011, Comput. Cardiol., 38, 285
- Graybeal J M Petterson M T, 2004, Proc. 26th Annu. Int. Conf. IEEE EMBS, 5363
- Huang B Kinsner W, 2002, Proc. 2002 IEEE Canadian Conf. on Electrical and Computer Engineering, 1105
- Krishnan R Natarajan B Warren S, 2008, Proc. 17th Int. Conf. on Computer Communications and Networks ICCCN '08, 1
- Krishnan R Natarajan B Warren S, 2008, IEEE Int. Conf. on Acoustics, Speech and Signal Processing, 613
- Lee C M Zhang Y T, 2003, IEEE EMBS Asian-Pacific Conf. on Biomed. Eng., 194
- Lee H W, 2007, Int. J. Control Autom. Syst., 5, 701
- Reddy K A Kumar V J, 2007, Proc. IEEE Instrumentation and Measurement Technology Conf. IMTC, 1
- Relente A R Sison L G, 2002, Proc. 2nd Joint EMBS/BMES Conf., 1769
- Sukanesh R, 2010, Biomed. Softw. Comput. Hum. Sci., 16, 135
- Vullings H J L M Verhaegen M H G Verbruggen H B, 1998, Proc. 20th Annu. Conf. IEEE EMBS, 163
- Yao J Warren S, 2005, IEEE-EMBS 27th Annu. Int. Conf. of the Engineering in Medicine and Biology Society, 3585
- Zong W, 2003, Comput. Cardiol., 30, 259
Cited by
Sorted by citations
Items 201–273 of 273
Groundtruth: A Matlab GUI for Artifact and Feature Identification in Physiological Signals
Naik, G. R., Gargiulo, G. D., Serrador, J. M., & Breen, P. P. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00850 · Cited by 4
Motion Artifact Reduction In Photoplethysmography For Reliable Signal Selection
Mao, R., Tweardy, M. J., Wegerich, S., Goergen, C. J., Wodicka, G. R., & Zhu, F. M. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630595 · Cited by 4
Signal quality evaluation of single-channel respiratory sEMG recordings
Sauer, J., Siebert, M., Boudnik, L., Carbon, N. M., Walterspacher, S., & Rostalski, P. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105414 · Cited by 4
Optimal filtering and smoothing thresholds for high-frequency photoplethysmography signals
Karolcik, S., & Georgiou, P. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558515 · Cited by 3
Berkebile, J. A., Inan, O. T., & Beach, P. A. (2025) · Frontiers in Network Physiology · doi:10.3389/fnetp.2025.1543838 · Cited by 4
Pflugradt, M., & Orglmeister, R. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943975 · Cited by 4
Photoplethysmogram analysis and applications: An Integrative Review (Preprint)
Shin, H., Park, J., Seok, H. S., & Kim, S. (2020) · JMIR Biomedical Engineering · doi:10.2196/25567 · Cited by 4
Macabiau, C., Le, T.-D., Albert, K., Shahriari, M., Jouvet, P. A., & Noumeir, R. (2024) · IEEE Access · doi:10.1109/access.2024.3411774 · Cited by 6
Blood Pressure Estimation with a Wristband Optical Sensor
Slapničar, G., & Luštrek, M. (2018) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3267305.3267708 · Cited by 4
Federated Learning for Data Mining in Healthcare
Sharma, S., Kesarwani, A., Maheshwari, S., & Rai, B. K. (2022) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-85559-8_16 · Cited by 4
Zhang, L., Lü, C., & Tao, L. (2016) · Journal of Vibroengineering · doi:10.21595/jve.2016.17377 · Cited by 4
Comparison of ECG fiducial point extraction methods based on dynamic Bayesian network
Akhbari, M., Shamsollahi, M. B., & Christian Jutten, B. (2017) · Iranian Conference on Electrical Engineering · doi:10.1109/iraniancee.2017.7985197 · Cited by 4
Shahrbabak, S. M., Bouzid, Z., Inan, O. T., & Hahn, J. (2025) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae0c4b · Cited by 3
Mitigating Hypovolemia-Induced Miscalibration of Photoplethysmogram-Derived Blood Pressure
Zia, J. S., Kimball, J. P., Hahn, J., & Inan, O. T. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175592 · Cited by 3
Effect of the Transimpedance Amplifier Topology on the Photoplethysmography Signal
Morillo, Á. S., Cause, J. L., da Silva, B., Naranjo, J. C. G., & Stiens, J. H. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9968674 · Cited by 3
Clustered photoplethysmogram pulse wave shapes and their associations with clinical data
Zanelli, S., Eveilleau, K., Charlton, P. H., Ammi, M., Hallab, M., & El‐Yacoubi, M. A. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1176753 · Cited by 3
Bose, A., Mukherjee, S., Chandra, J. K., Gupta, R., & Ghosh, D. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3351256 · Cited by 3
Sensor Agnostic Photoplethysmogram Signal Quality Assessment using Morphological Analysis
Alam, S., Datta, S., Choudhury, A. D., & Pal, A. (2017) · EAI International Conference on Mobile and Ubiquitous Systems: Computing, Networking and Services (MobiQuitous) · doi:10.1145/3144457.3144487 · Cited by 3
On robust extraction of pulse transit time from multimodal pulsatile signals
Zhu, Y., Zhang, H., & Guan, C. (2015) · IEEE International Conference on Digital Signal Processing (DSP) · doi:10.1109/icdsp.2015.7251902 · Cited by 3
Uncovering Voice Misuse Using Symbolic Mismatch
Ghassemi, M., Syed, Z., Mehta, D. D., Stan, J. H. V., Hillman, R. E., & Guttag, J. V. (2016) · PubMed · doi:10.48550/arxiv.1608.02301 · Cited by 3
Signal Processing: False Alarm Reduction
Li, Q., & Clifford, G. D. (2016) · Springer eBooks · doi:10.1007/978-3-319-43742-2_27 · Cited by 3
Self-citationCase Study on Measurement of SpO2 from PPG Signals in the Presence of Motion Artifact
Subhagya, D. S., Keshava Murthy., C., Aruna, N., Janardhan, L., & Ramakrishna, H. S. (2017) · International Conference on Recent Advances in Electronics and Communication Technology (ICRAECT) · doi:10.1109/icraect.2017.71 · Cited by 3
Lightweight ResNet-Based Deep Learning for Photoplethysmography Signal Quality Assessment
Zhao, Y., Kaisti, M., Lahdenoja, O., Sandelin, J., Anzanpour, A., Lehto, J., Nuotio, J., Jaakkola, J., Relander, A., Vasankari, T., et al. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11254566 · Cited by 2
Multimodal data classification using signal quality indices and empirical similarity-based reasoning
Xu, M., Shen, J., & Yu, H. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7411131 · Cited by 2
A Pulse Correlation Model for PPG Signal Quality Assessment and Key Pulse Extraction
Cheng, S., Liu, R., Wu, H., Sze, K. S.-F., & Feng, Q. (2024) · IEEE International Conference on Artificial Intelligence Circuits and Systems (AICAS) · doi:10.1109/aicas59952.2024.10595937 · Cited by 2
SINGLE-CYCLE PULSE WAVEFORM RECOGNITION METHOD BASED ON SVM
Li, Y., Geng, X., YAO, F., Wang, X., Wang, Y., Zhang, Y., & Wang, H. (2024) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519424400876 · Cited by 2
Zhao, Y., Lahdenoja, O., Sandelin, J., Seifizarei, S., Anzanpour, A., Lehto, J., Nuotio, J., Jaakkola, J., Relander, A., Vasankari, T., et al. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108688 · Cited by 2
Noise robust tamil speech word recognition system by means of PAC features with ANFIS
Rojathai, S., & Venkatesulu, M. A. (2014) · IEEE/ACIS International Conference on Computer and Information Science (ICIS) · doi:10.1109/icis.2014.6912173 · Cited by 2
Stratification of cardiopathies using photoplethysmographic signals
de Moraes, J. L., de Oliveira, T. L., Rocha, M. X., de Vasconcelos, G. G., & de Alexandria, A. R. (2020) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2020.100417 · Cited by 2
Wearable sensor technologies applied for post-stroke rehabilitation
Zhang, Z. (2015) · RMIT Research Repository (RMIT University Library) · doi:10.25439/rmt.27581808 · Cited by 2
Photoplethysmography Signal Quality Assessment using Attentive-CNN Models
Silva, L., Lima, R., Lucafo, G. D., Sandoval, I., Freitas, P. G., & Penatti, O. A. B. (2024) · doi:10.5753/sbcas.2024.2206 · Cited by 1
Multifractal features of multimodal cardiac signals: Nonlinear dynamics of exercise recovery
Maluckov, A., Stojanović, D. B., Miletić, M., Ivanović, M. D., Hadžievski, L. R., & Petrović, J. (2026) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0303657 · Cited by 1
Cho, M. J., Abbaraju, V., Rahman, F. N., Liu, J. C., Nawar, A., Murray, C. E., Yang, Y., Chiok, J., Choi, J., Bull, R., et al. (2025) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn66969.2025.11337294 · Cited by 1
Biswas, S., Islam, M. M., Islam, N., & Mia, M. A. R. (2026) · PLoS ONE · doi:10.1371/journal.pone.0341821 · Cited by 1
High-Reliability Signal Quality Validation for Biosignals Using Sensor Fusion and Software Indices
Adams, B. (2026) · Sensors · doi:10.3390/s26113478 · Cited by 1
Wert, J. C. V., Johnston, S. D., Johnston, Q. V. A., Zinn, K. R., Hendriks, B., Weber, L. A., Siders, Z. A., Patterson, D. A., Robinson, K. A., Eliason, E. J., et al. (2026) · Conservation Physiology · doi:10.1093/conphys/coag034 · Cited by 1
Pulse‐based photoplethysmography quality assessment improves wearable seizure detection performance
Shahbakhti, M., Bosch, A. T., Long, X., van Dijk, J. P., & Thijs, R. D. (2026) · Epilepsia Open · doi:10.1002/epi4.70242 · Cited by 1
A neonatal apnoea monitor for resource-constrained environments
Daly, J., Monasterio, V., & Clifford, G. D. (2012) · Cited by 1
Self-citationInvestigation of ANFIS and FFBNN Recognition Methods Performance in Tamil Speech Word Recognition
Rojathai, S., & Venkatesulu, M. A. (2014) · International Journal of Software Innovation · doi:10.4018/ijsi.2014040103 · Cited by 1
Qi, Y., Zhang, A., Ma, Y., Wang, H., Li, J., & Chen, C. (2023) · PubMed Central · doi:10.7507/1001-5515.202211054 · Cited by 1
On the Performance of Composite 1D-to-2D Projections for Signal Quality Assessment
Suzuki, G., & Freitas, P. G. (2024) · doi:10.5753/sbcas.2024.2207 · Cited by 1
A model for predicting emergency physician opinion of electrocardiogram tracing data quality
Goebel, M., Busico, L., Snow, G. L., & Bledsoe, J. R. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.05.001 · Cited by 1
Unobtrusive Measurement of Blood Pressure During Lifestyle Interventions
Sasso, A. M., Datta, S., Pfitzner, B., Zhou, L., Steckhan, N., Boettinger, E., & Bert Arnrich, A. (2019) · doi:10.4108/eai.20-5-2019.2283509 · Cited by 1
The reliability of objective fatigue measures in Multiple Sclerosis Patients
Olmo, G., Farolfi, F., Miola, F., Giorgi, S., Sapio, A. D., & Bertolotto, A. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101696 · Cited by 1
Localizing Placement of Cardiomechanical Sensors during Dynamic Periods via Template Matching
Zia, J. S., Kimball, J. P., & Inan, O. T. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176732 · Cited by 1
Evaluation of the Signal Quality of Wrist-Based Photoplethysmography
Pradhan, N. (2018) · doi:10.22215/etd/2018-12624 · Cited by 1
Enhanced Complex Event Processing Framework for Geriatric Remote Healthcare
Vaidehi, V., Pathak, R., Bhargavi, R. C., Ganapathy, K., Hemalatha, C. S., Fathima, A. A., Bhuvaneswari, P. T. V., Sethuraman, S. C., & Fernando, X. N. (2018) · Advances in computational intelligence and robotics book series · doi:10.4018/978-1-5225-5396-0.ch016
Foroozan, F., Xue, D., Fang, K. S., & Wu, J. S. (2020) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp40776.2020.9053550
Integration of Artifact Detection in Clinical Decision Support Systems
Nizami, S. (2016) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2016-11361
OuYoung, T., Weng, W.-L., Hu, T.-Y., Lee, C.-C., Wu, L.-W., & Hsiu, H. (2021) · Research Square · doi:10.21203/rs.3.rs-870679/v1
Machine Learning Approach on Photoplethysmogram Morphology for Psychiatric Disorders Prediction
Awang, A., Nayan, N. A., Jaafar, N. R. N., Suboh, M. Z., Rahman, K. A. A., & Ismail, S. N. A. (2022) · International Conference on Communications, Signal Processing, and their Applications (ICCSPA) · doi:10.1109/iccspa55860.2022.10019188
A pulse rate prediction method in artifacts segments based on Elman neural network
Miao, Y., An, A., Gong, B., Zhou, Y., & Chou, Y. (2023) · IEEE Information Technology, Networking, Electronic and Automation Control Conference (ITNEC) · doi:10.1109/itnec56291.2023.10081947
Huang, Y., Li, Y., & Ma, Z. (2023) · International Conference on Computer Engineering and Application (ICCEA) · doi:10.1109/iccea58433.2023.10135514
Han, W., Fu, C., & Zhang, L. (2024) · International Conference on Signal Processing Systems (ICSPS) · doi:10.1117/12.3022898
A Robust PPG Signal Processing Pipeline for Biomarker Extraction and Analysis
Kong, T., & Hedayatipour, A. (2025) · IEEE Dallas Circuits and Systems Conference (DCAS) · doi:10.1109/dcas65331.2025.11045453
Horst, S. T., van Wijk, R. J., Schoonhoven, A. D., de Lange, A., ter Maaten, J. C., & Bouma, H. R. (2025) · Journal of Critical Care · doi:10.1016/j.jcrc.2025.155241
A Multistage Signal Quality Framework for Blood Pressure Monitoring Using Photoplethysmography
Lai, J. C. Y., & Kar, P. (2025) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe66822.2025.00078
Amplitude Index for the Quality Assessment of Pulsatile Signals in Noise
Dai, W., Ding, X., Zheng, Y., & Zhang, Y. (2013) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-03005-0_58
Saccadic variability in patients with Parkinson’s disease
Baik, K., Byun, S., Kwag, S., Park, S. H., Kim, Y., Woo, T., Lee, S., Lee, C., Kim, G. J., Kim, B., et al. (2026) · Journal of Neurology · doi:10.1007/s00415-026-13733-0
Sato, S., & Nakayama, S. (2026) · Biomedical Engineering Advances · doi:10.1016/j.bea.2026.100220
Sivanjaneyulu, Y., Manikandan, M. S., & Boppu, S. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110643
Cook, J. M., Chen, C., Inan, F. B., Nichols, C. J., Rahman, F. N., Nawar, A., Reichelt, L. J., Cho, M., Sangar, Y., Hester, J., et al. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3702932
PhysQual: A quality-aware learning framework for robust remote photoplethysmography
Mohamad, F., Zulkernine, F. H., & Sears, K. (2026) · Smart Health · doi:10.1016/j.smhl.2026.100683 · Cited by 1
Chierico, P., Suárez, D., Fácila, L., Hornero, F., Alcaraz, R., & Rieta, J. J. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-24045-3_19
Context-Aware Wavelet Denoising of PPG Signals Using Clustered Accelerometer Features
Ricci, M., Suárez, D., Bertomeu‐González, V., Martínez‐Rodrigo, A., Alcaraz, R., & Rieta, J. J. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-24045-3_18
Dynamic beat-to-beat blood pressure estimation using a multi-modal wearable deep learning approach
Li, Q., Shen, Z., Almadi, M., Yang, Y., Zhang, N., Gong, J., Strangman, G. E., Xiang, T., Zhang, Y., Clifford, G. D., et al. (2026) · Physiological Measurement · doi:10.1088/1361-6579/ae85b4
Self-citationPhan, K. D., Lưu, T. T., Le, T. T., Tran-Quang, D.-H., & Huynh, V.-T. (2026) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ae91f1
Interpretable Reliability Control for Wearable PPG Heart Rate Estimation
Liang, Y., Zhang, S., & Yang, Z. (2026) · IEEE Access · doi:10.1109/access.2026.3730539
STQ-LSTM: Quality assessment for heart rate measured in practical driving via near-infrared imaging
Wen, Y., Liu, X., Yang, X., Zhou, Z., & Ma, K. (2026) · Measurement · doi:10.1016/j.measurement.2026.123464
Demographic subgroup-aware analysis of blood pressure predictive models
Kolawole, B., Fan, S., Lao, Y., & Koomson, V. J. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001687
Analysis of CNN-ANFIS Model for Cardiovascular System Vital Parameter Monitoring
Kutty, A., Chris Prema, S., & Selvaganesan, N. (2026) · IEEE International Conference on Recent Advances in Electronics, Communication, Computing, Automation and Power (RECCAP) · doi:10.1109/reccap69368.2026.11723370
Metadata
- Authors
- Li, Q., & Clifford, G. D.
- Affiliations
- Shandong University (CN)
- University of Oxford (GB)
- ORCID
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-08-17
- Volume
- 33
- Issue
- 9
- Pages
- 1491-1501
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1989977532
- Cited by
- 274
- References
- 31
- Citations by year
- 2026: 18 · 2025: 13 · 2024: 17 · 2023: 26 · 2022: 28 · 2021: 25 · 2020: 22 · 2019: 18 · 2018: 25 · 2017: 20 · 2016: 25 · 2015: 15 · 2014: 9 · 2013: 8 · 2012: 5
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmogram, signal quality assessment, dynamic time warping, template matching, multilayer perceptron, arrhythmia detection, intensive care monitoring
- MeSH terms
- Algorithms, Artificial Intelligence, Humans, Quality Control, Time Factors, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review