The DOI matches its Crossref record; 29 of the 31 references it cites were found in a registry or an index.
Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
Open accessAbstract
In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphology due to changes in heart rate, cardiac output, sensor type and hardware or software pre-processing requirements. Moreover, considerable inter-individual and sensor-location variability exists. Simple template matching methods are therefore inappropriate, and a patient-specific adaptive initialization is therefore required. We introduce dynamic time warping to stretch each beat to match a running template and combine it with several other features related to signal quality, including correlation and the percentage of the beat that appeared to be clipped. The features were then presented to a multi-layer perceptron neural network to learn the relationships between the parameters in the presence of good- and bad-quality pulses. An expert-labeled database of 1055 segments of PPG, each 6 s long, recorded from 104 separate critical care admissions during both normal and verified arrhythmic events, was used to train and test our algorithms. An accuracy of 97.5% on the training set and 95.2% on test set was found. The algorithm could be deployed as a stand-alone signal quality assessment algorithm for vetting the clinical utility of PPG traces or any similar quasi-periodic signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Some other examples are mentioned here: Bayesian network for classifying stress level [26,39] or for predicting patient's state [72], Fuzzy state machine for estimating the health status to provide alerts [68], logistic regression models [42] and association rules [41] to predict stress level and hospitalization of hemodialysis patients, respectively.”
From Data Mining for Wearable Sensors in Health Monitoring Systems: A Review of Recent Trends and Challenges (2013) · cites this paper as [72]
In the citing paper
“Several approaches have been proposed, including statistical analysis of pulse wave shape [56], assessing the level of perfusion through the perfusion index (the ratio of the amplitude of the pulsatile component of the PPG to its baseline) [56], assessing the similarity of successive pulse wave shapes using template matching [86] or dynamic time warping [87], and deep learning [88].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [87]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Faires, J. D. (1978) · Cited by 6,711
The Levenberg-Marquardt algorithm: Implementation and theory
Morè, J. J. (1978) · Lecture notes in mathematics · doi:10.1007/bfb0067700 · Cited by 5,796
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Exact indexing of dynamic time warping
Keogh, E., & Ratanamahatana, C. A. (2004) · Knowledge and Information Systems · doi:10.1007/s10115-004-0154-9 · Cited by 1,962
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400
An open-source algorithm to detect onset of arterial blood pressure pulses
Zong, W., Heldt, T., Moody, G. B., & Mark, R. G. (2003) · Computers in cardiology · doi:10.1109/cic.2003.1291140 · Cited by 326
Saeed, M., Lieu, C., RABER, G., & Mark, R. G. (2003) · Computers in cardiology · doi:10.1109/cic.2002.1166854 · Cited by 273
Signal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166
Signal processing methods for heart rate variability
Clifford, G. D. (2002) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-noa0mqzyn · Cited by 131
Self-citation
Research works printed but not linked: 14
- Addison P S Watson J N, 2010
- Clifford G D, 2011, Comput. Cardiol., 38, 285
- Graybeal J M Petterson M T, 2004, Proc. 26th Annu. Int. Conf. IEEE EMBS, 5363
- Huang B Kinsner W, 2002, Proc. 2002 IEEE Canadian Conf. on Electrical and Computer Engineering, 1105
- Krishnan R Natarajan B Warren S, 2008, Proc. 17th Int. Conf. on Computer Communications and Networks ICCCN '08, 1
- Krishnan R Natarajan B Warren S, 2008, IEEE Int. Conf. on Acoustics, Speech and Signal Processing, 613
- Lee C M Zhang Y T, 2003, IEEE EMBS Asian-Pacific Conf. on Biomed. Eng., 194
- Lee H W, 2007, Int. J. Control Autom. Syst., 5, 701
- Reddy K A Kumar V J, 2007, Proc. IEEE Instrumentation and Measurement Technology Conf. IMTC, 1
- Relente A R Sison L G, 2002, Proc. 2nd Joint EMBS/BMES Conf., 1769
- Sukanesh R, 2010, Biomed. Softw. Comput. Hum. Sci., 16, 135
- Vullings H J L M Verhaegen M H G Verbruggen H B, 1998, Proc. 20th Annu. Conf. IEEE EMBS, 163
- Yao J Warren S, 2005, IEEE-EMBS 27th Annu. Int. Conf. of the Engineering in Medicine and Biology Society, 3585
- Zong W, 2003, Comput. Cardiol., 30, 259
Cited by
Sorted by citations
Items 101–200 of 273
A Machine Learning Perspective on fNIRS Signal Quality Control Approaches
Bizzego, A., Neoh, M. J. Y., Gabrieli, G., & Esposito, G. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3198110 · Cited by 29
Song, J., Li, D., Ma, X., Teng, G., & Wei, J. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.05.020 · Cited by 25
Zhang, X., & Ding, Q. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.02.003 · Cited by 24
Jorge, J., Villarroel, M., Chaichulee, S., Green, G., McCormick, K. P., & Tarassenko, L. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2898273 · Cited by 25
Detecting heart failure using wearables: a pilot study
Shah, A. J., Isakadze, N., Levantsevych, O. M., Vest, A. N., Clifford, G. D., & Nemati, S. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab7f93 · Cited by 25
Self-citationPhotoplethysmogram Signal Quality Evaluation by Unsupervised Learning Approach
Roy, M. S., Gupta, R., & Sharma, K. D. (2020) · 2020 IEEE Applied Signal Processing Conference (ASPCON) · doi:10.1109/aspcon49795.2020.9276733 · Cited by 24
Suppression of false arrhythmia alarms using ECG and pulsatile waveforms
Couto, P., Ramalho, R., & Rodrigues, R. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7411019 · Cited by 24
PBGAN: Learning PPG Representations From GAN for Time-Stable and Unique Verification System
Hwang, D. Y., Taha, B., & Hatzinakos, D. (2021) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2021.3122817 · Cited by 25
Miao, F., Wu, D., Liu, Z.-D., Zhang, R., Tang, M., & Li, Y. (2022) · Chinese Medical Journal · doi:10.1097/cm9.0000000000002117 · Cited by 30
Dynamic signal quality index for electrocardiograms
Yaghmaie, N., Maddah-Ali, M. A., Jelinek, H. F., & Marzbanrad, F. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aadf02 · Cited by 23
A Multistep Paroxysmal Atrial Fibrillation Scanning Strategy in Long-Term ECGs
Ma, C., Liu, C., Wang, X., Li, Y., Wei, S., Lin, B., & Li, J. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3164138 · Cited by 22
Chatterjee, T., Ghosh, A., & Sarkar, S. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871494 · Cited by 22
Puri, C., Ukil, A., Bandyopadhyay, S., Singh, R., Pal, A., & Mandana, K. M. (2016) · doi:10.1145/2933566.2933567 · Cited by 22
Wander, J. D., & Morris, D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/12/2543 · Cited by 22
Valderrama, C. E., Marzbanrad, F., Stroux, L., Martinez, B., Hall‐Clifford, R., Liu, C., Katebi, N., Rohloff, P. J., & Clifford, G. D. (2018) · ACM SIGCAS Conference on Computing and Sustainable Societies (COMPASS) · doi:10.1145/3209811.3209815 · Cited by 21
Self-citationPhotoplethysmography signal quality assessment using attractor reconstruction analysis
Schmith, J., Kelsch, C., Cunha, B., Prade, L. R., Martins, E. A., Keller, A. L., & de Figueiredo, R. M. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105142 · Cited by 20
Classification of the quality of wristband-based photoplethysmography signals
Pradhan, N., Rajan, S., Adler, A., & Redpath, C. J. (2017) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2017.7985887 · Cited by 21
Personalized Continuous Blood Pressure Tracking Through Single Channel PPG in Wearable Scenarios
Zhang, Y., Zhou, C., Ren, X., Wang, Q., Wang, H., Xiang, T., Qiu, S., Zhang, Y., & Ye, X. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3535788 · Cited by 20
Heart-trend: An affordable heart condition monitoring system exploiting morphological pattern
Ukil, A., Bandyopadhyay, S., Puri, C., & Pal, A. (2016) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2016.7472881 · Cited by 20
Hybrid Optical Unobtrusive Blood Pressure Measurements
Zhang, G., Shan, C., Kirenko, I. O., Long, X., & Aarts, R. M. (2017) · Sensors · doi:10.3390/s17071541 · Cited by 19
Ferreira, A. F., Silva, H., Alves, H., Marques, N., & Fred, A. L. N. (2023) · Sensors · doi:10.3390/s23020620 · Cited by 17
Tissue mimicking materials and finger phantom design for pulse oximetry
Rodriguez, A., Vasudevan, S., Farahmand, M., Weininger, S., Vogt, W. C., Scully, C. G., Ramella‐Roman, J. C., & Pfefer, T. J. (2024) · Biomedical Optics Express · doi:10.1364/boe.518967 · Cited by 17
Pflugradt, M., Mann, S., Tigges, T., Görnig, M., & Orglmeister, R. (2015) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2014-0178 · Cited by 17
Wu, M., Liu, I.-F., Tzeng, Y.-H., & Wang, L. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac7d91 · Cited by 16
Unobtrusive Photoplethysmographic Monitoring Under the Foot Sole while in a Standing Posture
Hong, S., & Park, K. S. (2018) · Sensors · doi:10.3390/s18103239 · Cited by 16
Prada, E. J. A., Gallego, C. A. B., & García, J. F. C. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102606 · Cited by 16
Vardoulis, O., Saponas, T. S., Morris, D., Villar, N., Smith, G., Patel, S., & Tan, D. S. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.06.022 · Cited by 16
LSTM-based real-time signal quality assessment for blood volume pulse analysis
Gao, H., Zhang, C., Pei, S., & Wu, X. (2023) · Biomedical Optics Express · doi:10.1364/boe.477143 · Cited by 15
A Residual U-Net Neural Network for Seismocardiogram Denoising and Analysis During Physical Activity
Nikbakht, M. R., Chan, M., Lin, D. J., Gazi, A. H., & Inan, O. T. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3392532 · Cited by 15
Wearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation
Cheung, M. Y., Sabharwal, A., Coté, G. L., & Veeraraghavan, A. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3434344 · Cited by 23
Mixed Fuzzy Clustering for Misaligned Time Series
Salgado, C. M., Ferreira, M. C., & Vieira, S. M. (2016) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2016.2633375 · Cited by 15
Prasun, P., Mukhopadhyay, S., & Gupta, R. (2021) · Measurement Science and Technology · doi:10.1088/1361-6501/ac2d5b · Cited by 15
False arrhythmia alarms reduction in the intensive care unit: a multimodal approach
Fallet, S., Yazdani, S., & Vésin, J.-M. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/8/1217 · Cited by 15
Using pulse oximetry waveforms to detect coarctation of the aorta
Sorensen, M. W., Sadiq, I., Clifford, G. D., Maher, K., & Oster, M. E. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-00775-2 · Cited by 15
Self-citationBaumgartner, M., Veeranki, S. P. K., Hayn, D., & Schreier, G. (2023) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-023-00142-5 · Cited by 14
Template-based Quality Assessment of the Doppler Ultrasound Signal for Fetal Monitoring
Valderrama, C. E., Marzbanrad, F., Stroux, L., & Clifford, G. D. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00511 · Cited by 14
Self-citationA Pulse Signal Preprocessing Method Based on the Chauvenet Criterion
Ni, W., Qi, J., Liu, L., & Li, S. (2019) · Computational and Mathematical Methods in Medicine · doi:10.1155/2019/2067196 · Cited by 14
Localised photoplethysmography imaging for heart rate estimation of pre-term infants in the clinic
Green, G., Chaichulee, S., Villarroel, M., Jorge, J., Arteta, C., Zisserman, A., Tarassenko, L., & McCormick, K. P. (2018) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.2289759 · Cited by 13
Enhanced average for event-related potential analysis using dynamic time warping
Molina, M. E., Tardón, L. J., Barbancho, A. M., De-Torres, I., & Barbancho, I. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105531 · Cited by 13
Robust heart rate estimation from noisy phonocardiograms
Springer, D., Brennan, T. J., Hitzeroth, J., Mayosi, B. M., Tarassenko, L., & Clifford, G. D. (2014) · Computing in cardiology · Cited by 13
Self-citationOn-Device Multi-Level Signal Quality Aware Compression for Energy-Efficient Wearable PPG Sensing
Alam, S., Gupta, R., & Sharma, K. D. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3234171 · Cited by 12
Probabilistic model-based approach for heart beat detection
Chen, H., Erol, Y., Shen, E., & Russell, S. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/9/1404 · Cited by 13
vital_sqi: A Python package for physiological signal quality control
Khoa, L. D. V., Ho, H. B., Karolcik, S., Hernandez, B., Greeff, H., Nguyen, V. H., Phan, N. Q. K., Le, T. P., Thwaites, L., Georgiou, P., et al. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.1020458 · Cited by 11
Detection of artifacts on photoplethysmography signals using random distortion testing
Cherif, S., Pastor, D., Nguyen, Q.-T., & L’Her, E. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592148 · Cited by 11
Liu, C., Li, Q., & Clifford, G. D. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.265-207 · Cited by 11
Self-citationImaging Photoplethysmography: a Real-time Signal Quality Index
Fallet, S., Schoenenberger, Y., Martin, L., Braun, F., Moser, V., & Vésin, J.-M. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.142-139 · Cited by 11
Machine-aided PPG Signal Quality Assessment (SQA) for Multi-mode Physiological Signal Monitoring
Beh, W.-K., Yang, Y.-C., Lo, Y.-C., Lee, Y.-C., & Wu, A.-Y. A. (2023) · ACM Transactions on Computing for Healthcare · doi:10.1145/3587256 · Cited by 10
SensIPro: Smart sensor analytics for Internet of things
Bandyopadhyay, S., Ukil, A., Puri, C., Singh, R., Bose, T., & Pal, A. (2016) · IEEE Symposium on Computers and Communications (ISCC) · doi:10.1109/iscc.2016.7543775 · Cited by 10
Dynamic Time Warping for Quantitative Analysis of Tracer Study Time-Series Water Quality Data
Woo, H., Boccelli, D. L., Uber, J. G., Janke, R., & Su, Y. (2019) · Journal of Water Resources Planning and Management · doi:10.1061/(asce)wr.1943-5452.0001115 · Cited by 10
Identification of AF and Other Cardiac Arrhythmias from a Single-lead ECG Using Dynamic Time Warping
Tziakouri, M., Pitris, C., & Orphanidou, C. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.348-295 · Cited by 10
Hermawan, I., Ma’Sum, M. A., Intan, P. R. D., Jatmiko, W., Wiweko, B., Boediman, A., & Pradekso, B. K. (2019) · International Workshop on Big Data and Information Security (IWBIS) · doi:10.1109/iwbis.2019.8935757 · Cited by 10
fNIRS-QC: Crowd-Sourced Creation of a Dataset and Machine Learning Model for fNIRS Quality Control
Gabrieli, G., Bizzego, A., Neoh, M. J. Y., & Esposito, G. (2021) · Applied Sciences · doi:10.3390/app11209531 · Cited by 10
Sarkar, S., & Ghosh, A. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106240 · Cited by 9
HYPE: Predicting Blood Pressure from Photoplethysmograms in a Hypertensive Population
Sasso, A. M., Datta, S., Jeitler, M., Steckhan, N., Keßler, C. S., Michalsen, A., Bert Arnrich, A., & Böttinger, E. P. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-59137-3_29 · Cited by 9
Ukil, A., Bandyoapdhyay, S., Puri, C., Pal, A., & Mandana, K. M. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.082-334 · Cited by 9
Assessment of photoplethysmogram signal quality based on frequency domain and time series parameters
Zhang, Y., & Pan, J. (2017) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp-bmei.2017.8302279 · Cited by 9
Tiwari, A., Gray, G., Bondi, P., Mahnam, A., & Falk, T. H. (2023) · Sensors · doi:10.3390/s23125606 · Cited by 9
Real-Time Quality Index to Control Data Loss in Real-Life Cardiac Monitoring Applications
Vila, G., Godin, C., Charbonnier, S., & Campagne, A. (2021) · Sensors · doi:10.3390/s21165357 · Cited by 8
A Machine Learning Approach for the Automatic Estimation of Fixation-Time Data Signals’ Quality
Gabrieli, G., Balagtas, J. P. M., Esposito, G., & Setoh, P. (2020) · Sensors · doi:10.3390/s20236775 · Cited by 7
Robust Assessment of Photoplethysmogram Signal Quality in the Presence of Atrial Fibrillation
Pereira, T., Gadhoumi, K., Ma, M., Colorado, R. A., Keenan, K. J., Meisel, K. M., & Hu, X. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.254 · Cited by 8
A Quality Assessment System for PPG Waveform
Hao, J., & Gao, B. (2021) · doi:10.1109/iccs52645.2021.9697132 · Cited by 8
Nguyen, D. H., Chao, P. C.-P., Shuai, H.-H., Fang, Y., & Lin, B.-S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3148415 · Cited by 8
Data-Driven Guided Attention for Analysis of Physiological Waveforms With Deep Learning
Martinez, J., Nowroozilarki, Z., Jafari, R., & Mortazavi, B. J. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3199199 · Cited by 8
Machine-Learning Classification of Pulse Waveform Quality
OuYoung, T., Weng, W.-L., Hu, T.-Y., Lee, C.-C., Wu, L., & Hsiu, H. (2022) · Sensors · doi:10.3390/s22228607 · Cited by 8
Influence of Photoplethysmogram Signal Quality on Pulse Arrival Time during Polysomnography
Rinkevičius, M., Charlton, P. H., Bailón, R., & Marozas, V. (2023) · Sensors · doi:10.3390/s23042220 · Cited by 11
An Exercise Health Simulation Method Based on Integrated Human Thermophysiological Model
Jia, N., Chen, X., Yu, L., Wang, R., Yang, K., & Luo, X. (2017) · Computational and Mathematical Methods in Medicine · doi:10.1155/2017/9073706 · Cited by 8
Guichard, L., An, X., Neylan, T. C., Clifford, G. D., Li, Q., Ji, Y., Macchio, L., Baker, J., Beaudoin, F. L., Jovanović, T., et al. (2024) · Psychiatry Research · doi:10.1016/j.psychres.2024.116260 · Cited by 11
Self-citationIsmaiel, E., Fiáth, R., Szabó, Á., Horváth, Á. C., & Fekete, Z. (2023) · Scientific Reports · doi:10.1038/s41598-023-41552-0 · Cited by 7
Quality-Aware Signal Processing Mechanism of PPG Signal for Long-Term Heart Rate Monitoring
Beh, W.-K., Yang, Y.-C., & Wu, A.-Y. A. (2024) · Sensors · doi:10.3390/s24123901 · Cited by 7
Roy, M. S., Bag, P., & Gupta, R. (2019) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tensymp46218.2019.8971035 · Cited by 7
Boosted-SpringDTW for Comprehensive Feature Extraction of PPG Signals
Martinez, J., Sel, K., Mortazavi, B. J., & Jafari, R. (2022) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2022.3174806 · Cited by 7
Assessing the Quality of Photoplethysmograms via Gramian Angular Fields and Vision Transformer
Freitas, P. G., Lima, R. G. D., Lucafo, G. D., & Penatti, O. A. B. (2023) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco58844.2023.10290014 · Cited by 7
Sensor based efficient decision making framework for remote healthcare
Ganapathy, K., Vaidehi, V., & Poorani, D. (2015) · Journal of Ambient Intelligence and Smart Environments · doi:10.3233/ais-150330 · Cited by 7
Serackis, A., Abromavičius, V., & Gudiškis, A. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7411130 · Cited by 7
Stübinger, J., & Adler, K. (2020) · Algorithms · doi:10.3390/a13040095 · Cited by 7
Albaba, A., Castro, I. D., Borzée, P., Buyse, B., Testelmans, D., Varon, C., Huffel, S. V., & Torfs, T. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102775 · Cited by 7
COVID-19 Detection Using Photoplethysmography and Neural Networks
Lombardi, S., Francia, P., Deodati, R., Calamai, I., Luchini, M., Spina, R., & Bocchi, L. (2023) · Sensors · doi:10.3390/s23052561 · Cited by 8
Hwang, C., Kim, Y. H., Hyun, J. K., Kim, J. H., Lee, S. R., Kim, C. M., Nam, J., & Kim, E. Y. (2023) · Bioengineering · doi:10.3390/bioengineering10101222 · Cited by 6
A method for assessing the reliability of heart rates obtained from ambulatory ECG
Orphanidou, C., Bonnici, T., Vallance, D., Darrell, A., Charlton, P. H., & Tarassenko, L. (2012) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2012.6399672 · Cited by 6
NB-SQI: A novel non-binary signal quality index for continuous blood pressure waveforms
Ignácz, A., Földi, S., Sótonyi, P., & Cserey, G. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103035 · Cited by 6
Learning based Quality Indicator Aiding Heart Rate Estimation in Wrist-Worn PPG
Lutin, E., Biswas, D., Simoes-Capela, N., Hoof, C. A. V., & Helleputte, N. V. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630910 · Cited by 6
Artifacts classification and apnea events detection in neck photoplethysmography signals
García-López, I., Pramono, R. X. A., & Rodriguez–Villegas, E. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02666-1 · Cited by 6
Detection of false arrhythmia alarms with emphasis on ventricular tachycardia
Rodrigues, R., & Couto, P. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/8/1326 · Cited by 6
A Novel Abnormal Segments Detection Method for Photopletysmography Signal
Teng, Y., Ge, L., & Chou, Y. (2018) · Chinese Control Conference (CCC) · doi:10.23919/chicc.2018.8483815 · Cited by 6
Derivation of Respiratory Metrics in Health and Asthma
Prinable, J., Jones, P. W., Boland, D., McEwan, A. L., & Thamrin, C. (2020) · Sensors · doi:10.3390/s20247134 · Cited by 6
A New Score Level Fusion Approach for Stable User Verification System Using the PPG Signal
Hwang, D. Y., Taha, B., & Hatzinakos, D. (2022) · Journal of Signal Processing Systems · doi:10.1007/s11265-022-01747-6 · Cited by 6
Bizzego, A., & Furlanello, C. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/118943 · Cited by 6
Nawar, A., Kilic, O. S., Rahman, F. N., Chen, C., Berkebile, J. A., Chan, M., Shah, A. J., & Inan, O. T. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3596522 · Cited by 5
Photoplethysmogram Signal Quality Assessment via 1D-to-2D Projections and Vision Transformers
Freitas, P. G., Lima, R. G. D., Lucafo, G. D., & Penatti, O. A. B. (2023) · International Conference on Quality of Multimedia Experience (QoMEX) · doi:10.1109/qomex58391.2023.10178569 · Cited by 5
Baciu, V.-E., Cause, J. L., Morillo, Á. S., Naranjo, J. C. G., Stiens, J. H., & da Silva, B. (2023) · Sensors · doi:10.3390/s23156947 · Cited by 5
OPRA: A fast on-line signal quality estimator for pulsatile signals
Pflugradt, M., Moeller, B., & Orglmeister, R. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.10.183 · Cited by 5
Classification of AF and other arrhythmias from a short segment of ECG using dynamic time warping
Tziakouri, M., Pitris, C., & Orphanidou, C. (2017) · Computing in cardiology · Cited by 5
Song, L., Wang, H., & Chen, P. (2018) · Measurement · doi:10.1016/j.measurement.2018.12.036 · Cited by 5
SleepAp: An automated obstructive sleep apnoea screening application for smartphones
Behar, J. A., Roebuck, A., Shahid, M. F., Daly, J., Hallack, A., Palmius, N., Stradling, J. R., & Clifford, G. D. (2013) · Computing in cardiology · Cited by 5
Self-citationECG-Aided PPG Signal Quality Assessment (SQA) System for Heart Rate Estimation
Yang, Y.-C., Beh, W.-K., Lo, Y.-C., Wu, A.-Y. A., & Lu, S.-J. (2020) · SiPS ... design and implementation - IEEE Workshop on Signal Processing Systems · doi:10.1109/sips50750.2020.9195211 · Cited by 5
Signal Quality Analysis in Pulse Oximetry: Modelling and Detection of Motion Artifact
Clarke, G. (2015) · doi:10.22215/etd/2015-10956 · Cited by 5
Mula, S., Zangróniz, R., Martín, Ó. A., Rieta, J. J., & Alcaraz, R. (2025) · IEEE Access · doi:10.1109/access.2025.3604652 · Cited by 4
Javierre, M., Julián, P. A., Puñet, R. L., Cajal, D., Wadhwani, N., Lázaro, J. M., & Bailón, R. (2025) · Companion Publication of the International Conference on Multimodal Interaction (ICMI Companion) · doi:10.1145/3747327.3764789 · Cited by 4
Sah, R. K., Rahman, M. M., Nathan, V., Zhu, L., Bae, J., Rosa, C., Mendes, W. B., Kuang, J., & Gao, A. J. (2024) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp48485.2024.10447778 · Cited by 4
Morphological Photoplethysmography Features Enhance Stress Detection in Earbud Sensors
Zhang, L., Nathan, V., Rosa, C., Kuang, J., Mendes, W. B., & Gao, J. A. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782695 · Cited by 4
Metadata
- Authors
- Li, Q., & Clifford, G. D.
- Affiliations
- Shandong University (CN)
- University of Oxford (GB)
- ORCID
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-08-17
- Volume
- 33
- Issue
- 9
- Pages
- 1491-1501
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1989977532
- Cited by
- 274
- References
- 31
- Citations by year
- 2026: 18 · 2025: 13 · 2024: 17 · 2023: 26 · 2022: 28 · 2021: 25 · 2020: 22 · 2019: 18 · 2018: 25 · 2017: 20 · 2016: 25 · 2015: 15 · 2014: 9 · 2013: 8 · 2012: 5
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmogram, signal quality assessment, dynamic time warping, template matching, multilayer perceptron, arrhythmia detection, intensive care monitoring
- MeSH terms
- Algorithms, Artificial Intelligence, Humans, Quality Control, Time Factors, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review