Estimation of human core temperature from sequential heart rate observations
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Core temperature (CT) in combination with heart rate (HR) can be a good indicator of impending heat exhaustion for occupations involving exposure to heat, heavy workloads, and wearing protective clothing. However, continuously measuring CT in an ambulatory environment is difficult. To address this problem we developed a model to estimate the time course of CT using a series of HR measurements as a leading indicator using a Kalman filter. The model was trained using data from 17 volunteers engaged in a 24 h military field exercise (air temperatures 24-36 °C, and 42%-97% relative humidity and CTs ranging from 36.0-40.0 °C). Validation data from laboratory and field studies (N = 83) encompassing various combinations of temperature, hydration, clothing, and acclimation state were examined using the Bland-Altman limits of agreement (LoA) method. We found our model had an overall bias of -0.03 ± 0.32 °C and that 95% of all CT estimates fall within ±0.63 °C (>52 000 total observations). While the model for estimating CT is not a replacement for direct measurement of CT (literature comparisons of esophageal and rectal methods average LoAs of ±0.58 °C) our results suggest it is accurate enough to provide practical indication of thermal work strain for use in the work place.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Procedures for Detecting Outlying Observations in Samples
Grubbs, F. E. (1969) · Technometrics · doi:10.1080/00401706.1969.10490657 · Cited by 4,105
Influence of graded dehydration on hyperthermia and cardiovascular drift during exercise
Montain, S. J., & Coyle, E. F. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.73.4.1340 · Cited by 769
Self-citationIndividualized model of human thermoregulation for the simulation of heat stress response
Havenith, G. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.5.1943 · Cited by 299
A non-invasive device to continuously determine heat strain in humans
Gunga, H.-C., Sandsund, M., Reinertsen, R. E., Sattler, F., & Koch, J. (2008) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2008.03.004 · Cited by 129
Gunga, H.-C., Werner, A., Stahn, A., Steinach, M., Schlabs, T., Koralewski, E., Kunz, D., Belavý, D. L., Felsenberg, D., Sattler, F., et al. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.04.005 · Cited by 122
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“For instance, telemetric pill’s measurements are greatly influenced by the ingestion of hot or cold fluids [67,73].”
BackgroundThermal Indices and Thermophysiological Modeling for Heat Stress
Havenith, G., & Fiala, D. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140051 · Cited by 262
Eggenberger, P., MacRae, B. A., Kemp, S., Bürgisser, M., Rossi, R. M., & Annaheim, S. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01780 · Cited by 91
Thermometry and interpretation of body temperature
Chen, W. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00102-2 · Cited by 72
Metadata
- Authors
- Buller, M. J., Tharion, W. J., Cheuvront, S. N., Montain, S. J., Kenefick, R. W., Castellani, J., Latzka, W. A., Roberts, W. S., Richter, M., Jenkins, O. C., & Hoyt, R. W.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2013-06-19
- Volume
- 34
- Issue
- 7
- Pages
- 781-798
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2013801614
- Cited by
- 175
- References
- 7
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of human core temperature from sequential heart rate observations. https://app.cochat.ai/papers/10.1088/0967-3334/34/7/781
- The paper
- Buller, M. J., Tharion, W. J., Cheuvront, S. N., Montain, S. J., Kenefick, R. W., Castellani, J., Latzka, W. A., Roberts, W. S., Richter, M., Jenkins, O. C., & Hoyt, R. W. (2013). Estimation of human core temperature from sequential heart rate observations. Physiological Measurement. https://doi.org/10.1088/0967-3334/34/7/781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.