Estimation of human core temperature from sequential heart rate observations
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Core temperature (CT) in combination with heart rate (HR) can be a good indicator of impending heat exhaustion for occupations involving exposure to heat, heavy workloads, and wearing protective clothing. However, continuously measuring CT in an ambulatory environment is difficult. To address this problem we developed a model to estimate the time course of CT using a series of HR measurements as a leading indicator using a Kalman filter. The model was trained using data from 17 volunteers engaged in a 24 h military field exercise (air temperatures 24-36 °C, and 42%-97% relative humidity and CTs ranging from 36.0-40.0 °C). Validation data from laboratory and field studies (N = 83) encompassing various combinations of temperature, hydration, clothing, and acclimation state were examined using the Bland-Altman limits of agreement (LoA) method. We found our model had an overall bias of -0.03 ± 0.32 °C and that 95% of all CT estimates fall within ±0.63 °C (>52 000 total observations). While the model for estimating CT is not a replacement for direct measurement of CT (literature comparisons of esophageal and rectal methods average LoAs of ±0.58 °C) our results suggest it is accurate enough to provide practical indication of thermal work strain for use in the work place.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
An Introduction to the Kalman Filter
Welch, G., & Bishop, G. (1995) · CiteSeer X (The Pennsylvania State University) · Cited by 7,039
Procedures for Detecting Outlying Observations in Samples
Grubbs, F. E. (1969) · Technometrics · doi:10.1080/00401706.1969.10490657 · Cited by 4,105
Fick, A. (1855) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786445508641925 · Cited by 944
Influence of graded dehydration on hyperthermia and cardiovascular drift during exercise
Montain, S. J., & Coyle, E. F. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.73.4.1340 · Cited by 769
Self-citationFiala, D., Lomas, K. J., & Stohrer, M. (2001) · International Journal of Biometeorology · doi:10.1007/s004840100099 · Cited by 754
Physiological measurements of metabolic functions in man.
(1963) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1963.03700260090052 · Cited by 635
A physiological strain index to evaluate heat stress
Moran, D. S., Shitzer, A., & Pandolf, K. B. (1998) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1998.275.1.r129 · Cited by 620
Byrne, C., & Lim, C. L. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.026344 · Cited by 456
Human Thermoregulation and Measurement of Body Temperature in Exercise and Clinical Settings
Lim, C. L., Byrne, C., & Lee, J. K. (2008) · Annals of the Academy of Medicine, Singapore · doi:10.47102/annals-acadmedsg.v37n4p347 · Cited by 373
Lefrant, J.-Y., Muller, L., de La Coussaye, J. E., Benbabaali, M., Lebris, C., Zeitoun, N., Mari, C., Saïssi, G., Ripart, J., & Eledjam, J.-J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1619-5 · Cited by 303
Individualized model of human thermoregulation for the simulation of heat stress response
Havenith, G. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.5.1943 · Cited by 299
Thermoregulatory and blood responses during exercise at graded hypohydration levels
Sawka, M. N., Young, A. J., Francesconi, R. P., Muza, S. R., & Pandolf, K. B. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.5.1394 · Cited by 282
The Effect of Cool Water Ingestion on Gastrointestinal Pill Temperature
WILKINSON, D. M., CARTER, J. M., RICHMOND, V. L., BLACKER, S. D., & RAYSON, M. P. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815cc43e · Cited by 195
ACSM's advanced exercise physiology
Tipton, C. M., Sawka, M. N., Tate, C. A., & Terjung, R. L. (2006) · Medical Entomology and Zoology · Cited by 175
A New Method for Monitoring Deep Body Temperature from the Skin Surface
Fox, R. H., Solman, A. J., Isaacs, R., Fry, A. J., & MacDonald, I. C. (1973) · Clinical Science · doi:10.1042/cs0440081 · Cited by 168
Hyperhydration: tolerance and cardiovascular effects during uncompensable exercise-heat stress
Latzka, W. A., Sawka, M. N., Montain, S. J., Skrinar, G. S., Fielding, R. A., Matott, R. P., & Pandolf, K. B. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.6.1858 · Cited by 138
Self-citationA non-invasive device to continuously determine heat strain in humans
Gunga, H.-C., Sandsund, M., Reinertsen, R. E., Sattler, F., & Koch, J. (2008) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2008.03.004 · Cited by 129
Gunga, H.-C., Werner, A., Stahn, A., Steinach, M., Schlabs, T., Koralewski, E., Kunz, D., Belavý, D. L., Felsenberg, D., Sattler, F., et al. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.04.005 · Cited by 122
Non-invasive continuous core temperature measurement by zero heat flux
Teunissen, L. P. J., Klewer, J., de Haan, A., de Koning, J. J., & Daanen, H. A. M. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/5/005 · Cited by 107
Hyperhydration: thermoregulatory effects during compensable exercise-heat stress
Latzka, W. A., Sawka, M. N., Montain, S. J., Skrinar, G. S., Fielding, R. A., Matott, R. P., & Pandolf, K. B. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.3.860 · Cited by 100
Self-citationLEE, J. K. W., Nio, A. Q. X., Lim, C. L., Teo, E. Y. N., & Byrne, C. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1405-y · Cited by 100
Kraning, K. K., & Gonzalez, R. R. (1997) · Journal of Thermal Biology · doi:10.1016/s0306-4565(97)00031-4 · Cited by 97
Physiological Systems and Their Responses to Conditions of Heat and Cold
Kenefick, R. W., Cheuvront, S. N., Montain, S. J., Carter, R., Sawka, M. N., Gonzalez, R. R., Ely, B. R., Moran, D. S., Hadid, A., & Endrusick, T. L. (2006) · Cited by 74
Self-citationFrank, A., Belokopytov, M., Shapiro, Y., & Epstein, Y. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210000368 · Cited by 63
Evaluation of the limits to accurate sweat loss prediction during prolonged exercise
Cheuvront, S. N., Montain, S. J., Goodman, D. A., Blanchard, L., & Sawka, M. N. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0492-x · Cited by 51
Self-citationThermoregulatory model to predict physiological status from ambient environment and heart rate
Yokota, M., Berglund, L. G., Cheuvront, S. N., Santee, W. R., Latzka, W. A., Montain, S. J., Kolka, M. A., & Moran, D. S. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.09.003 · Cited by 48
Self-citationEstimation of Human Internal Temperature from Wearable Physiological Sensors
Buller, M., Tharion, W., Hoyt, R., & Jenkins, O. (2010) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v24i2.18809 · Cited by 47
Self-citationThermal-Work Strain During Marine Rifle Squad Operations in Afghanistan
Welles, A. P., Buller, M. J., Margolis, L. M., Economos, D., Hoyt, R. W., & Richter, M. (2013) · Military Medicine · doi:10.7205/milmed-d-12-00538 · Cited by 39
Self-citationEvaluation of a newly developed monitor of deep body temperature
Yamakage, M., Iwasaki, S., & Namiki, A. (2002) · Journal of Anesthesia · doi:10.1007/s005400200056 · Cited by 33
Al-Mukhaizeem, F., Allen, U., Komar, L., Naser, B., Roy, L., Stephens, D., Read, S., Kim, C., & Schuh, S. (2004) · Paediatrics & Child Health · doi:10.1093/pch/9.7.461 · Cited by 28
Human thermoregulatory system state estimation using non-invasive physiological sensors
Buller, M. J., Castellani, J., Roberts, W. S., Hoyt, R. W., & Jenkins, O. C. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6090893 · Cited by 17
Self-citationBestimmung der Körperkerntemperatur während der postoperativen Wiedererwärmung
Bräuer, A., Weyland, W., Fritz, U., Schuhmann, M. U., Schmidt, J. H., & Braun, U. (1997) · Der Anaesthesist · doi:10.1007/s001010050454 · Cited by 16
DEET insect repellent: effects on thermoregulatory sweating and physiological strain
Kenefick, R. W., Cheuvront, S. N., Ely, B. R., Palombo, L. J., & Sawka, M. N. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1932-1 · Cited by 8
Self-citation
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“For instance, telemetric pill’s measurements are greatly influenced by the ingestion of hot or cold fluids [67,73].”
BackgroundThermal Indices and Thermophysiological Modeling for Heat Stress
Havenith, G., & Fiala, D. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140051 · Cited by 262
“NICT has become central also to the development of new intelligent PPE systems, personal monitoring, and heat stress warning systems for military and civilian applications (24,26,57,59,133, 188).”
InfluentialMilitary applications of soldier physiological monitoring
Friedl, K. E. (2018) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2018.06.004 · Cited by 194
Eggenberger, P., MacRae, B. A., Kemp, S., Bürgisser, M., Rossi, R. M., & Annaheim, S. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01780 · Cited by 91
Metadata
- Authors
- Buller, M. J., Tharion, W. J., Cheuvront, S. N., Montain, S. J., Kenefick, R. W., Castellani, J., Latzka, W. A., Roberts, W. S., Richter, M., Jenkins, O. C., & Hoyt, R. W.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2013-06-19
- Volume
- 34
- Issue
- 7
- Pages
- 781-798
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2013801614
- Cited by
- 175
- References
- 35
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.