Activity classification based on inertial and barometric pressure sensors at different anatomical locations
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Miniature, wearable sensor modules are a promising technology to monitor activities of daily living (ADL) over extended periods of time. To assure both user compliance and meaningful results, the selection and placement site of sensors requires careful consideration. We investigated these aspects for the classification of 16 ADL in 6 healthy subjects under laboratory conditions using ReSense, our custom-made inertial measurement unit enhanced with a barometric pressure sensor used to capture activity-related altitude changes. Subjects wore a module on each wrist and ankle, and one on the trunk. Activities comprised whole body movements as well as gross and dextrous upper-limb activities. Wrist-module data outperformed the other locations for the three activity groups. Specifically, overall classification accuracy rates of almost 93% and more than 95% were achieved for the repeated holdout and user-specific validation methods, respectively, for all 16 activities. Including the altitude profile resulted in a considerable improvement of up to 20% in the classification accuracy for stair ascent and descent. The gyroscopes provided no useful information for activity classification under this scheme. The proposed sensor setting could allow for robust long-term activity monitoring with high compliance in different patient populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Theoretical and Empirical Analysis of ReliefF and RReliefF
Robnik-Šikonja, M., & Kononenko, I. (2003) · Machine Learning · doi:10.1023/a:1025667309714 · Cited by 3,025 · cited 1×
“The assigned weight ranges from −1 to 1, with large positive values given to important attributes (Robnik-Sikonja and Kononenko 2003).”
BackgroundActivity recognition using cell phone accelerometers
Kwapisz, J. R., Weiss, G. M., & Moore, S. A. (2011) · ACM SIGKDD Explorations Newsletter · doi:10.1145/1964897.1964918 · Cited by 2,912
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551 · cited 6×
“A testing point is then placed in this space and its class is predicted according to the majority of the k-nearest neighbors of training data (Preece et al 2009b).”
BackgroundMethodInfluentialWireless body sensor networks for health-monitoring applications
Hao, Y., & Foster, R. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/11/r01 · Cited by 404 · cited 1×
“…especially for aspects such as activity levels (Bouten et al 1997), changes in habits (e.g. mental/physical decline in the elderly population (Hao and Foster 2008)), or functional recovery (e.g. following orthopedic or neurological injury) outside the clinical environment (Uswatte et al…”
BackgroundFeature Selection and Activity Recognition from Wearable Sensors
Pirttikangas, S., Fujinami, K., & Nakajima, T. (2006) · Lecture Notes in Computer Science · doi:10.1007/11890348_39 · Cited by 229
Cited by
Physical Human Activity Recognition Using Wearable Sensors
Attal, F., Mohammed, S., Dedabrishvili, M., Chamroukhi, F., Oukhellou, L., & Amirat, Y. (2015) · Sensors · doi:10.3390/s151229858 · Cited by 796
A Survey of Online Activity Recognition Using Mobile Phones
Shoaib, M., Bosch, S., Incel, O., Scholten, H., & Havinga, P. (2015) · Sensors · doi:10.3390/s150102059 · Cited by 489
“The usefulness of fusing a barometer with the accelerometer for better activity recognition has been shown in a few studies [67,68].”
BackgroundComplex Human Activity Recognition Using Smartphone and Wrist-Worn Motion Sensors
Shoaib, M., Bosch, S., Incel, O., Scholten, H., & Havinga, P. (2016) · Sensors · doi:10.3390/s16040426 · Cited by 423
“Usually, additional sensors, such as a gyroscope [10] and a barometer [11], are combined with the accelerometer to reliably recognize using stairs: walking upstairs and downstairs.”
MethodA survey on wearable sensor modality centred human activity recognition in health care
Wang, Y., Cang, S., & Yu, H. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.04.057 · Cited by 409
Advanced internet of things for personalised healthcare systems: A survey
Qi, J., Yang, P., Min, G., Amft, O., Dong, F., & Xu, L. (2017) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2017.06.018 · Cited by 406
Metadata
- Authors
- Moncada-Torres, A., Leuenberger, K., Gonzenbach, R., Luft, A., & Gassert, R.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-05-22
- Volume
- 35
- Issue
- 7
- Pages
- 1245-1263
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2122102074
- Cited by
- 113
- References
- 6
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Activity classification based on inertial and barometric pressure sensors at different anatomical locations. https://app.cochat.ai/papers/10.1088/0967-3334/35/7/1245
- The paper
- Moncada-Torres, A., Leuenberger, K., Gonzenbach, R., Luft, A., & Gassert, R. (2014). Activity classification based on inertial and barometric pressure sensors at different anatomical locations. Physiological Measurement. https://doi.org/10.1088/0967-3334/35/7/1245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.