Magnetic particle imaging: from proof of principle to preclinical applications
The DOI matches its Crossref record; 117 of the 117 references it cites were found in a registry or an index.
Abstract
Tomographic imaging has become a mandatory tool for the diagnosis of a majority of diseases in clinical routine. Since each method has its pros and cons, a variety of them is regularly used in clinics to satisfy all application needs. Magnetic particle imaging (MPI) is a relatively new tomographic imaging technique that images magnetic nanoparticles with a high spatiotemporal resolution in a quantitative way, and in turn is highly suited for vascular and targeted imaging. MPI was introduced in 2005 and now enters the preclinical research phase, where medical researchers get access to this new technology and exploit its potential under physiological conditions. Within this paper, we review the development of MPI since its introduction in 2005. Besides an in-depth description of the basic principles, we provide detailed discussions on imaging sequences, reconstruction algorithms, scanner instrumentation and potential medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Heating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,551
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003 · cited 8×
“The spatial resolution is medium but can potentially be improved to reach 1 mm or even below (Gleich and Weizenecker 2005).”
BackgroundMethodInfluentialDesign and fabrication of magnetic nanoparticles for targeted drug delivery and imaging
Veiseh, O., Gunn, J. W., & Zhang, M. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.002 · Cited by 1,832
Magnetic nanomaterials for hyperthermia-based therapy and controlled drug delivery
Kumar, C. S. S. R., & Mohammad, F. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.03.008 · Cited by 1,666
Multifunctional magnetic nanoparticles for targeted imaging and therapy
MCCARTHY, J., & WEISSLEDER, R. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.014 · Cited by 892
Clinical applications of magnetic nanoparticles for hyperthermia
Thiesen, B., & Jordan, A. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730802104757 · Cited by 829
Jordan, A., Wust, P., Fählin, H., John, W., Hinz, A., & Felix, R. (1993) · International Journal of Hyperthermia · doi:10.3109/02656739309061478 · Cited by 694
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651 · cited 2×
“scanner it was possible to quantify the difference in the MPI signal that corresponded to the difference in implanted cells. Depending on the iron load of each cell and the MPI hardware used, the detection limit varied in different publications from 200 Zheng et al (2015) to 50 000 cells Bulte et al (2015). Them et al…”
Method
Cited by
Solving inverse problems using data-driven models
Arridge, S., Maass, P., Öktem, O., & Schönlieb, C.-B. (2019) · Acta Numerica · doi:10.1017/s0962492919000059 · Cited by 686
Israel, L. L., Galstyan, A., Holler, E., & Ljubimova, J. Y. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.01.009 · Cited by 337
Human-sized magnetic particle imaging for brain applications
Graeser, M., Thieben, F., Szwargulski, P., Werner, F., Gdaniec, N., Boberg, M., Griese, F., Möddel, M., Ludewig, P., van de Ven, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09704-x · Cited by 334
Self-citationSong, G., Chen, M., Zhang, Y., Cui, L., Qu, H., Zheng, X., Wintermark, M., Liu, Z., & Rao, J. (2018) · Nano Letters · doi:10.1021/acs.nanolett.7b03829 · Cited by 256
Hadadian, Y., Masoomi, H., Dinari, A., Ryu, C., Hwang, S., Kim, S., Cho, B. K., Lee, J. Y., & Yoon, J. (2022) · ACS Omega · doi:10.1021/acsomega.2c01136 · Cited by 159
“Although narrow size distribution may be the necessary condition for several applications such as magnetic recording 16 or biomedical imaging, 17 it is not a su ffi cient condition either; for the former, magnetically hard nanoparticles are desirable, while for the latter, a very soft magnetic…”
Advancement of magnetic particle imaging in diagnosis and therapy
Harini, K., Girigoswami, K., Pallavi, P., Gowtham, P., Prabhu, A. D., & Girigoswami, A. (2024) · Advances in Natural Sciences: Nanoscience and Nanotechnology · doi:10.1088/2043-6262/ad3b7a · Cited by 8
Metadata
- Authors
- Knopp, T., Gdaniec, N., & Möddel, M.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2017-06-23
- Volume
- 62
- Issue
- 14
- Pages
- R124-R178
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2607206317
- Cited by
- 238
- References
- 117
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.