The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Magnetic nanomaterials for hyperthermia-based therapy and controlled drug delivery
Open accessAbstract
Previous attempts to review the literature on magnetic nanomaterials for hyperthermia-based therapy focused primarily on magnetic fluid hyperthermia (MFH) using mono metallic/metal oxide nanoparticles. The term “Hyperthermia” in the literature was also confined only to include use of heat for therapeutic applications. Recently, there have been a number of publications demonstrating magnetic nanoparticle-based hyperthermia to generate local heat resulting in the release of drugs either bound to the magnetic nanoparticle or encapsulated within polymeric matrices. In this review article, we present a case for broadening the meaning of the term “hyperthermia” by including thermotherapy as well as magnetically modulated controlled drug delivery. We provide a classification for controlled drug delivery using hyperthermia: Hyperthermia-based controlled Drug delivery through Bond Breaking (DBB) and Hyperthermia-based controlled Drug delivery through Enhanced Permeability (DEP). The review also covers, for the first time, core-shell type magnetic nanomaterials, especially nanoshells prepared using layer-by-layer self-assembly, for the application of hyperthermia-based therapy and controlled drug delivery. The highlight of the review article is to portray potential opportunities in the combination of hyperthermia-based therapy and controlled drug release paradigms for successful application in personalized medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monodisperse FePt Nanoparticles and Ferromagnetic FePt Nanocrystal Superlattices
Sun, S., Murray, C. B., Weller, D., Folks, L., & Moser, A. (2000) · Science · doi:10.1126/science.287.5460.1989 · Cited by 6,137
Factors affecting the clearance and biodistribution of polymeric nanoparticles
Alexis, F., Pridgen, E., Molnar, L. K., & Farokhzad, O. C. (2008) · Molecular Pharmaceutics · doi:10.1021/mp800051m · Cited by 3,699
Biodegradable polymeric nanoparticles as drug delivery devices
Soppimath, K. S., Aminabhavi, T. M., Kulkarni, A. R., & Rudzinski, W. E. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(00)00339-4 · Cited by 3,549
Clinical applications of magnetic nanoparticles for hyperthermia
Thiesen, B., & Jordan, A. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730802104757 · Cited by 829
Nanotheranostics and image-guided drug delivery: current concepts and future directions
Lammers, T., Kiessling, F., Hennink, W. E., & Storm, G. (2010) · Molecular Pharmaceutics · doi:10.1021/mp100228v · Cited by 397
One-Step Synthesis of FePt Nanoparticles with Tunable Size
Chen, M., Liu, J. P., & Sun, S. (2004) · Journal of the American Chemical Society · doi:10.1021/ja047648m · Cited by 368
Thermosensitive liposomes entrapping iron oxide nanoparticles for controllable drug release
Tai, L.-A., Tsai, P.-J., Wang, Y.-C., Wang, Y.-J., Lo, L.-W., & Yang, C.-S. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/13/135101 · Cited by 145
Magnetoliposomes for controlled drug release in the presence of low-frequency magnetic field
Nappini, S., Bombelli, F. B., Bonini, M., Nordèn, B., & Baglioni, P. (2010) · Soft Matter · doi:10.1039/b915651h · Cited by 113
Cited by
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
Ferrite-based magnetic nanofluids used in hyperthermia applications
Sharifi, I., Shokrollahi, H., & Amiri, S. (2012) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2011.10.017 · Cited by 759
Magnetic nanoparticles for environmental and biomedical applications: a review
Mohammed, L., Gomaa, H. G., Ragab, D., & Zhu, J. (2017) · Particuology · doi:10.1016/j.partic.2016.06.001 · Cited by 682
Enzyme-responsive nanomaterials for controlled drug delivery
Hu, Q., Katti, P. S., & Gu, Z. (2014) · Nanoscale · doi:10.1039/c4nr04249b · Cited by 668
Metadata
- Authors
- Kumar, C. S. S. R., & Mohammad, F.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 2011-08
- Volume
- 63
- Issue
- 9
- Pages
- 789-808
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W2025531782
- Cited by
- 1,666
- References
- 8
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic nanomaterials for hyperthermia-based therapy and controlled drug delivery. https://app.cochat.ai/papers/10.1016/j.addr.2011.03.008
- The paper
- Kumar, C. S. S. R., & Mohammad, F. (2011). Magnetic nanomaterials for hyperthermia-based therapy and controlled drug delivery. Advanced Drug Delivery Reviews. https://doi.org/10.1016/j.addr.2011.03.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.