The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy
Open accessAbstract
To enable magnetic resonance (MR)-only radiotherapy and facilitate modelling of radiation attenuation in humans, synthetic CT (sCT) images need to be generated. Considering the application of MR-guided radiotherapy and online adaptive replanning, sCT generation should occur within minutes. This work aims at assessing whether an existing deep learning network can rapidly generate sCT images for accurate MR-based dose calculations in the entire pelvis. A study was conducted on data of 91 patients with prostate (59), rectal (18) and cervical (14) cancer who underwent external beam radiotherapy acquiring both CT and MRI for patients' simulation. Dixon reconstructed water, fat and in-phase images obtained from a conventional dual gradient-recalled echo sequence were used to generate sCT images. A conditional generative adversarial network (cGAN) was trained in a paired fashion on 2D transverse slices of 32 prostate cancer patients. The trained network was tested on the remaining patients to generate sCT images. For 30 patients in the test set, dose recalculations of the clinical plan were performed on sCT images. Dose distributions were evaluated comparing voxel-based dose differences, gamma and dose-volume histogram (DVH) analysis. The sCT generation required 5.6 s and 21 s for a single patient volume on a GPU and CPU, respectively. On average, sCT images resulted in a higher dose to the target of maximum 0.3%. The average gamma pass rates using the 3%, 3 mm and 2%, 2 mm criteria were above 97 and 91%, respectively, for all volumes of interests considered. All DVH points calculated on sCT differed less than ±2.5% from the corresponding points on CT. Results suggest that accurate MR-based dose calculation using sCT images generated with a cGAN trained on prostate cancer patients is feasible for the entire pelvis. The sCT generation was sufficiently fast for integration in an MR-guided radiotherapy workflow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Unpaired image-to-image translation using cycle-consistent adversarial networks
Zhu, J.-Y., Park, T., Isola, P., & Efros, A. A. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.244 · Cited by 23,602
Image-to-Image Translation with Conditional Adversarial Networks
Isola, P., Zhu, J.-Y., Zhou, T., & Efros, A. A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.632 · Cited by 22,930
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718
MR-based synthetic CT generation using a deep convolutional neural network method
Han, X. (2017) · Medical Physics · doi:10.1002/mp.12155 · Cited by 711
Medical Image Synthesis with Context-Aware Generative Adversarial Networks
Nie, D., Trullo, R., Lian, J., Petitjean, C., Ruan, S., Wang, Q., & Shen, D. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66179-7_48 · Cited by 691
Deep MR to CT Synthesis Using Unpaired Data
Wolterink, J. M., Dinkla, A. M., Savenije, M. H. F., Seevinck, P. R., van den Berg, C. A. T., & Išgum, I. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-68127-6_2 · Cited by 593
Self-citationRaaymakers, B. W., Jürgenliemk-Schulz, I. M., Bol, G. H., Glitzner, M., Kotte, A. N. T. J., van Asselen, B., de Boer, J. C. J., Bluemink, J. J., Hackett, S. L., Moerland, M. A., et al. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa9517 · Cited by 541
Self-citationA review of substitute CT generation for MRI-only radiation therapy
Edmund, J. M., & Nyholm, T. (2017) · Radiation Oncology · doi:10.1186/s13014-016-0747-y · Cited by 378
Radiotherapy planning using MRI
Schmidt, M. A., & Payne, G. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/r323 · Cited by 357
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320
Johnstone, E., Wyatt, J. J., Henry, A. M., Short, S. C., Sebag-Montefiore, D., Murray, L., Kelly, C. G., McCallum, H. M., & Speight, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.08.043 · Cited by 317
Raaijmakers, A. J. E., Raaymakers, B. W., & Lagendijk, J. J. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/006 · Cited by 264
Leynes, A. P., Yang, J., Wiesinger, F., Kaushik, S. S., Shanbhag, D. D., Seo, Y., Hope, T. A., & Larson, P. E. Z. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.198051 · Cited by 250
Hollingsworth, K. G. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/r297 · Cited by 238
MRI-only treatment planning: benefits and challenges
Owrangi, A. M., Greer, P. B., & Glide-Hurst, C. K. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aaaca4 · Cited by 236
Lagendijk, J. J. W., Raaymakers, B. W., Van den Berg, C. A. T., Moerland, M. A., Philippens, M. E., & van Vulpen, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/21/r349 · Cited by 206
Self-citationDowling, J. A., Sun, J., Pichler, P., Rivest-Hénault, D., Ghose, S., Richardson, H., Wratten, C., Martin, J., Arm, J., Best, L., et al. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.08.045 · Cited by 180
Nyholm, T., Nyberg, M., Karlsson, M. G., & Karlsson, M. (2009) · Radiation Oncology · doi:10.1186/1748-717x-4-54 · Cited by 165
MRI simulation for radiotherapy treatment planning
Devic, S. (2012) · Medical Physics · doi:10.1118/1.4758068 · Cited by 158
Dinkla, A. M., Wolterink, J. M., Maspero, M., Savenije, M. H. F., Verhoeff, J. J. C., Seravalli, E., Išgum, I., Seevinck, P. R., & van den Berg, C. A. T. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.058 · Cited by 151
Self-citationSiversson, C., Nordström, F., Nilsson, T., Nyholm, T., Jonsson, J. H., Gunnlaugsson, A., & Olsson, L. E. (2015) · Medical Physics · doi:10.1118/1.4931417 · Cited by 138
Thor, M., Petersen, J. B. B., Bentzen, L., Høyer, M., & Muren, L. P. (2011) · Acta Oncologica · doi:10.3109/0284186x.2011.577806 · Cited by 133
Persson, E., Gustafsson, C. J., Nordström, F., Sohlin, M. C., Gunnlaugsson, A., Petruson, K. M., Rintelä, N., Hed, K., Blomqvist, L., Zackrisson, B., et al. (2017) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.06.006 · Cited by 96
The Role of Hypofractionated Radiotherapy in Prostate Cancer
Benjamin, L. C., Tree, A. C., & Dearnaley, D. P. (2017) · Current Oncology Reports · doi:10.1007/s11912-017-0584-7 · Cited by 71
Maspero, M., van den Berg, C. A. T., Landry, G., Belka, C., Parodi, K., Seevinck, P. R., Raaymakers, B. W., & Kurz, C. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa9677 · Cited by 51
Self-citationQuantification of confounding factors in MRI-based dose calculations as applied to prostate IMRT
Maspero, M., Seevinck, P. R., Schubert, G., Hoesl, M. A. U., van Asselen, B., Viergever, M. A., Lagendijk, J. J. W., Meijer, G. J., & van den Berg, C. A. T. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa4fe7 · Cited by 46
Self-citationThor, M., Bentzen, L., Elstrøm, U. V., Petersen, J. B. B., & Muren, L. P. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.814151 · Cited by 32
Wang, H., Du, K. L., Qu, J., Chandarana, H., & Das, I. J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0190883 · Cited by 25
Low, D. A. (2017) · Cancer treatment and research · doi:10.1007/978-3-319-53235-6_3 · Cited by 8
Cited by
Generative adversarial network in medical imaging: A review
Yi, X., Walia, E., & Babyn, P. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101552 · Cited by 1,863
Deep learning in medical imaging and radiation therapy
Sahiner, B., Pezeshk, A., Hadjiiski, L. M., Wang, X., Drukker, K., Cha, K. H., Summers, R. M., & Giger, M. L. (2019) · Medical Physics · doi:10.1002/mp.13264 · Cited by 740
Artificial intelligence and machine learning for medical imaging: A technology review
Barragán-Montero, A., Javaid, U., Valdés, G., Nguyen, D., Desbordes, P., Macq, B., Willems, S., Vandewinckele, L., Holmström, M., Löfman, F., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.04.016 · Cited by 450
Shifting machine learning for healthcare from development to deployment and from models to data
Zhang, A., Xing, L., Zou, J., & Wu, J. C. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00898-y · Cited by 420
Artificial intelligence in radiation oncology
Huynh, E., Hosny, A., Guthier, C., Bitterman, D. S., Petit, S. F., Haas-Kogan, D. A., Kann, B., Aerts, H. J. W. L., & Mak, R. H. (2020) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-020-0417-8 · Cited by 419
Metadata
- Authors
- Maspero, M., Savenije, M. H. F., Dinkla, A. M., Seevinck, P. R., Intven, M. P. W., Jurgenliemk-Schulz, I. M., Kerkmeijer, L. G. W., & van den Berg, C. A. T.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2018-09-10
- Volume
- 63
- Issue
- 18
- Pages
- 185001
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2886009883
- Cited by
- 253
- References
- 33
- FWCI
- 25.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).