3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The treatment planning process for patients with head and neck (H&N) cancer is regarded as one of the most complicated due to large target volume, multiple prescription dose levels, and many radiation-sensitive critical structures near the target. Treatment planning for this site requires a high level of human expertise and a tremendous amount of effort to produce personalized high quality plans, taking as long as a week, which deteriorates the chances of tumor control and patient survival. To solve this problem, we propose to investigate a deep learning-based dose prediction model, Hierarchically Densely Connected U-net, based on two highly popular network architectures: U-net and DenseNet. We find that this new architecture is able to accurately and efficiently predict the dose distribution, outperforming the other two models, the Standard U-net and DenseNet, in homogeneity, dose conformity, and dose coverage on the test data. Averaging across all organs at risk, our proposed model is capable of predicting the organ-at-risk max dose within 6.3% and mean dose within 5.1% of the prescription dose on the test data. The other models, the Standard U-net and DenseNet, performed worse, having an averaged organ-at-risk max dose prediction error of 8.2% and 9.3%, respectively, and averaged mean dose prediction error of 6.4% and 6.8%, respectively. In addition, our proposed model used 12 times less trainable parameters than the Standard U-net, and predicted the patient dose 4 times faster than DenseNet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Densely Connected Convolutional Networks
Huang, G., Liu, Z., Van Der Maaten, L., & Weinberger, K. Q. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.243 · Cited by 48,566
Fully convolutional networks for semantic segmentation
Long, J., Shelhamer, E., & Darrell, T. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298965 · Cited by 38,834
Breiman, L. (1996) · Machine Learning · doi:10.1007/bf00058655 · Cited by 16,325
V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation
Milletari, F., Navab, N., & Ahmadi, S.-A. (2016) · 2016 Fourth International Conference on 3D Vision (3DV) · doi:10.1109/3dv.2016.79 · Cited by 11,931
Fully convolutional networks for semantic segmentation
Shelhamer, E., Long, J., & Darrell, T. (2017) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2016.2572683 · Cited by 11,898
Backpropagation Applied to Handwritten Zip Code Recognition
LeCun, Y., Boser, B., Denker, J. S., Henderson, D., Howard, R. E., Hubbard, W., & Jackel, L. D. (1989) · Neural Computation · doi:10.1162/neco.1989.1.4.541 · Cited by 11,891
Learning Deconvolution Network for Semantic Segmentation
Noh, H., Hong, S., & Han, B. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.178 · Cited by 4,422 · cited 1×
“There is no direct inverse operation to max pooling, but some common techniques to increase the resolution include upsampling and deconvolution (Noh et al 2015).”
MethodH-DenseUNet: Hybrid Densely Connected UNet for Liver and Tumor Segmentation From CT Volumes
Li, X., Chen, H., Qi, X., Dou, Q., Fu, C.-W., & Heng, P.-A. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2845918 · Cited by 2,473
Volumetric modulated arc therapy: IMRT in a single gantry arc
Otto, K. (2008) · Medical Physics · doi:10.1118/1.2818738 · Cited by 1,882
Automatic early stopping using cross validation: quantifying the criteria
Prechelt, L. (1998) · Neural Networks · doi:10.1016/s0893-6080(98)00010-0 · Cited by 990
Object Recognition with Gradient-Based Learning
LeCun, Y., Haffner, P., Bottou, L., & Bengio, Y. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-46805-6_19 · Cited by 947 · cited 1×
“CNNs were first proposed in by LeCun et al (1998, 1999), and had quickly found their use in deep learning for computer vision and imaging tasks.”
MethodMax-pooling convolutional neural networks for vision-based hand gesture recognition
Nagi, J., Ducatelle, F., Di Caro, G. A., Ciresan, D., Meier, U., Giusti, A., Nagi, F., Schmidhuber, J., & Gambardella, L. M. (2011) · 2011 IEEE International Conference on Signal and Image Processing Applications (ICSIPA) · doi:10.1109/icsipa.2011.6144164 · Cited by 644
Radiotherapy Dose–Volume Effects on Salivary Gland Function
Deasy, J. O., Moiseenko, V., Marks, L., Chao, K. S. C., Nam, J., & Eisbruch, A. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.090 · Cited by 590
Radiation Dose–Volume Effects in the Spinal Cord
Kirkpatrick, J. P., van der Kogel, A. J., & Schultheiss, T. E. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.04.095 · Cited by 541
Loss of local control with prolongation in radiotherapy
Fowler, J. F., & Lindstrom, M. J. (1992) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(92)90768-d · Cited by 489
Bese, N. S., Hendry, J., & Jeremic, B. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.03.010 · Cited by 382 · cited 1×
“…tumors, where tumor volume can double in approximately 30 d, which account for 50% of patients (Jensen et al 2007), an extended planning time can greatly decrease local tumor control and patient survival (Bese et al 2007, Fowler and Lindstrom 1992, Fein et al 1996, González Ferreira et al 2015).”
BackgroundPredicting dose‐volume histograms for organs‐at‐risk in IMRT planning
Appenzoller, L. M., Michalski, J. M., Thorstad, W. L., Mutic, S., & Moore, K. L. (2012) · Medical Physics · doi:10.1118/1.4761864 · Cited by 382
Optimisation of conformal radiotherapy dose distribution by simulated annealing
Webb, S. (1989) · Physics in Medicine and Biology · doi:10.1088/0031-9155/34/10/002 · Cited by 339
A planning quality evaluation tool for prostate adaptive IMRT based on machine learning
Zhu, X., Ge, Y., Li, T., Thongphiew, D., Yin, F., & Wu, Q. J. (2011) · Medical Physics · doi:10.1118/1.3539749 · Cited by 324
Gupta, T., Agarwal, J., Jain, S., Phurailatpam, R., Kannan, S., Ghosh-Laskar, S., Murthy, V., Budrukkar, A., Dinshaw, K., Prabhash, K., et al. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.07.001 · Cited by 319
Intensity-modulated radiation therapy for head and neck cancer: Systematic review and meta-analysis
Marta, G. N., Silva, V., de Andrade Carvalho, H., de Arruda, F. F., Hanna, S. A., Gadia, R., da Silva, J. L. F., Correa, S. F. M., Vita Abreu, C. E. C., & Riera, R. (2014) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.11.010 · Cited by 313
Tumor progression in waiting time for radiotherapy in head and neck cancer
Jensen, A. R., Nellemann, H. M., & Overgaard, J. (2007) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.04.001 · Cited by 309
Yuan, L., Ge, Y., Lee, W. R., Yin, F. F., Kirkpatrick, J. P., & Wu, Q. J. (2012) · Medical Physics · doi:10.1118/1.4757927 · Cited by 285
Evaluation of a Knowledge-Based Planning Solution for Head and Neck Cancer
Tol, J. P., Delaney, A. R., Dahele, M., Slotman, B. J., & Verbakel, W. F. A. R. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.11.014 · Cited by 279
Paulino, A. C., Koshy, M., Howell, R., Schuster, D., & Davis, L. W. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.08.037 · Cited by 264
Wu, B., Ricchetti, F., Sanguineti, G., Kazhdan, M., Simari, P., Jacques, R., Taylor, R., & McNutt, T. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.05.026 · Cited by 260
Shiraishi, S., & Moore, K. L. (2015) · Medical Physics · doi:10.1118/1.4938583 · Cited by 237
Radiation Dose–Volume Effects in the Larynx and Pharynx
Rancati, T., Schwarz, M., Allen, A. M., Feng, F., Popovtzer, A., Mittal, B., & Eisbruch, A. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.03.079 · Cited by 236
Ferreira, J. A. G., Jaén, J., Azinovic, I., & Jeremic, B. M. (2015) · Reports of Practical Oncology & Radiotherapy · doi:10.1016/j.rpor.2015.05.010 · Cited by 176
Tribius, S., & Bergelt, C. (2011) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2011.01.004 · Cited by 130
Shaffer, R. E., Morris, W. J., Moiseenko, V., Welsh, M., Crumley, C., Nakano, S., Schmuland, M., Pickles, T., & Otto, K. F. (2009) · Clinical Oncology · doi:10.1016/j.clon.2009.01.014 · Cited by 92
Matsuo, M., Miwa, K., Tanaka, O., Shinoda, J., Nishibori, H., Tsuge, Y., Yano, H., Iwama, T., Hayashi, S., Hoshi, H., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.09.020 · Cited by 83
Cited by
Artificial intelligence and machine learning for medical imaging: A technology review
Barragán-Montero, A., Javaid, U., Valdés, G., Nguyen, D., Desbordes, P., Macq, B., Willems, S., Vandewinckele, L., Holmström, M., Löfman, F., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.04.016 · Cited by 450
Self-citationRevolutionizing radiation therapy: the role of AI in clinical practice
Kawamura, M., Kamomae, T., Yanagawa, M., Kamagata, K., Fujita, S., Ueda, D., Matsui, Y., Fushimi, Y., Fujioka, T., Nozaki, T., et al. (2024) · Journal of Radiation Research · doi:10.1093/jrr/rrad090 · Cited by 86
“DL methods learn the contour and dose distribution inputs to the CT for treatment planning and automatically generate dose distributions by inputting new contours [62, 63].”
MethodBarragán-Montero, A. M., Thomas, M., Defraene, G., Michiels, S., Haustermans, K., Lee, J. A., & Sterpin, E. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.026 · Cited by 69
“The DL model architecture was inspired from the popular U-Net [36], a type of fully convolutional network widely used for medical image segmentation and other medical applications [19,51–53].”
BackgroundMethodInfluentialA feasibility study of automating radiotherapy planning with large language model agents
Wang, Q., Wang, Z., Li, M., Ni, X., Tan, R., Zhang, W., Wubulaishan, M., Wang, W., Yuan, Z., Zhang, Z., et al. (2025) · Physics in Medicine & Biology · doi:10.1088/1361-6560/adbff1 · Cited by 28
“…predicting pixel-level or voxel-level dose distributions from patient anatomy, achieving significantly better predictive performance (Barragán-Montero et al 2019, Kajikawa et al 2019, Lee et al 2019, Nguyen et al 2019, Kandalan et al 2020, Murakami et al 2020, Shao et al 2020, Sumida et al 2020).”
InfluentialA Survey on Deep Learning for Precision Oncology
Wang, C.-W., Khalil, M.-A., & Firdi, N. (2022) · Diagnostics · doi:10.3390/diagnostics12061489 · Cited by 23
Metadata
- Authors
- Nguyen, D., Jia, X., Sher, D., Lin, M.-H., Iqbal, Z., Liu, H., & Jiang, S.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2019-03-18
- Volume
- 64
- Issue
- 6
- Pages
- 065020
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2804847842
- Cited by
- 318
- References
- 34
- FWCI
- 27.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.