Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using CycleGAN for adaptive radiation therapy
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Throughout the course of delivering a radiation therapy treatment, which may take several weeks, a patient’s anatomy may change drastically, and adaptive radiation therapy (ART) may be needed. Cone-beam computed tomography (CBCT), which is often available during the treatment process, can be used for both patient positioning and ART re-planning. However, due to the prominent amount of noise, artifacts, and inaccurate Hounsfield unit (HU) values, the dose calculation based on CBCT images could be inaccurate for treatment planning. One way to solve this problem is to convert CBCT images to more accurate synthesized CT (sCT) images. In this work, we have developed a cycle-consistent generative adversarial network framework (CycleGAN) to synthesize CT images from CBCT images. This model is capable of image-to-image translation using unpaired CT and CBCT images in an unsupervised learning setting. The sCT images generated from CBCT through this CycleGAN model are visually and quantitatively similar to real CT images with decreased mean absolute error (MAE) from 69.29 HU to 29.85 HU for head-and-neck (H&N) cancer patients. The dose distributions calculated on the sCT by CycleGAN demonstrated a higher accuracy than those on CBCT in a 3D gamma index analysis with increased gamma index pass rate from 86.92% to 96.26% under 1 mm/1% criteria, when using the deformed planning CT image (dpCT) as the reference. We also compared the CycleGAN model with other unsupervised learning methods, including deep convolutional generative adversarial networks (DCGAN) and progressive growing of GANs (PGGAN), and demonstrated that CycleGAN outperformed the other two models. A phantom study has been conducted to compare sCT with dpCT, and the increase of structural similarity index from 0.91 to 0.93 shows that CycleGAN performed better than DIR in terms of preserving anatomical accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Unpaired image-to-image translation using cycle-consistent adversarial networks
Zhu, J.-Y., Park, T., Isola, P., & Efros, A. A. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.244 · Cited by 23,602
Image-to-Image Translation with Conditional Adversarial Networks
Isola, P., Zhu, J.-Y., Zhou, T., & Efros, A. A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.632 · Cited by 22,930 · cited 2×
“A 70 × 70 patchGAN was used in image-to-image translation for 256 × 256 image resolution (Isola et al 2017), because the full ImageGAN not only does not improve the visual quality of the results, but may even generate lower quality.”
BackgroundMethodUnsupervised representation learning with deep convolutional generative adversarial networks
Radford, A., Metz, L., & Chintala, S. (2015) · arXiv · doi:10.48550/arxiv.1511.06434 · Cited by 12,235
High-Resolution Image Synthesis and Semantic Manipulation with Conditional GANs
Wang, T.-C., Liu, M.-Y., Zhu, J.-Y., Tao, A., Kautz, J., & Catanzaro, B. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00917 · Cited by 5,360
Progressive Growing of GANs for Improved Quality, Stability, and Variation
Karras, T., Aila, T., Laine, S., & Lehtinen, J. (2017) · arXiv · doi:10.48550/arxiv.1710.10196 · Cited by 4,727
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311 · cited 2×
“CT1 is acquired under 60 ml saline water, simulating pCT. CT2 and CBCT2 are acquired under 30 ml saline water, simulating the re-scanned CT and CBCT during the treatment course. sCT is generated by GAN models from CBCT2, and dpCT is generated by deforming CT1 to CBCT2’s anatomy using the DIR package from Elastix.”
MethodDeep MR to CT Synthesis Using Unpaired Data
Wolterink, J. M., Dinkla, A. M., Savenije, M. H. F., Seevinck, P. R., van den Berg, C. A. T., & Išgum, I. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-68127-6_2 · Cited by 593
Conebeam CT of the Head and Neck, Part 1: Physical Principles
Miracle, A. C., & Mukherji, S. K. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1653 · Cited by 387
Hiasa, Y., Otake, Y., Takao, M., Matsuoka, T., Takashima, K., Carass, A., Prince, J. L., Sugano, N., & Sato, Y. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00536-8_4 · Cited by 221
Xu, Y. X., Bai, T., Yan, H., Ouyang, L., Pompoš, A., Wang, J., Zhou, L., Jiang, S. B., & Jia, X. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/9/3567 · Cited by 134
Self-citationKurz, C., Kamp, F., Park, Y., Zöllner, C., Rit, S., Hansen, D. C., Podesta, M., Sharp, G. C., Li, M., Reiner, M. J., et al. (2016) · Medical Physics · doi:10.1118/1.4962933 · Cited by 125
Graves, Y. J., Smith, A.-A., McIlvena, D., Manilay, Z., Lai, Y. K., Rice, R. K., Mell, L. K., Jia, X., Jiang, S. B., & Cerviño, L. (2015) · Medical Physics · doi:10.1118/1.4908205 · Cited by 37
Self-citation
Cited by
Artificial intelligence and machine learning for medical imaging: A technology review
Barragán-Montero, A., Javaid, U., Valdés, G., Nguyen, D., Desbordes, P., Macq, B., Willems, S., Vandewinckele, L., Holmström, M., Löfman, F., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.04.016 · Cited by 450
Self-citationGlide-Hurst, C. K., Lee, P., Yock, A. D., Olsen, J. R., Cao, M., Siddiqui, F., Parker, W., Doemer, A., Rong, Y., Kishan, A. U., et al. (2021) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2020.10.021 · Cited by 317
A review on medical imaging synthesis using deep learning and its clinical applications
Wang, T., Lei, Y., Fu, Y., Wynne, J. F., Curran, W. J., Liu, T., & Yang, X. (2021) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13121 · Cited by 279
Paired cycle‐GAN‐based image correction for quantitative cone‐beam computed tomography
Harms, J., Lei, Y., Wang, T., Zhang, R., Zhou, J., Tang, X., Curran, W. J., Liu, T., & Yang, X. (2019) · Medical Physics · doi:10.1002/mp.13656 · Cited by 257
Liu, Y., Lei, Y., Wang, T., Fu, Y., Tang, X., Curran, W. J., Liu, T., Patel, P., & Yang, X. (2020) · Medical Physics · doi:10.1002/mp.14121 · Cited by 205
Metadata
- Authors
- Liang, X., Chen, L., Nguyen, D., Zhou, Z., Gu, X., Yang, M., Wang, J., & Jiang, S.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2019-06-01
- Volume
- 64
- Issue
- 12
- Pages
- 125002
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2898727287
- Cited by
- 262
- References
- 12
- FWCI
- 23.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.