Experimental time resolution limits of modern SiPMs and TOF-PET detectors exploring different scintillators and Cherenkov emission
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Solid state photodetectors like silicon photomultipliers (SiPMs) are playing an important role in several fields of medical imaging, life sciences and high energy physics. They are able to sense optical photons with a single photon detection time precision below 100 ps, making them ideal candidates to read the photons generated by fast scintillators in time of flight positron emission tomography (TOF-PET). By implementing novel high-frequency readout electronics, it is possible to perform a completely new evaluation of the best timing performance achievable with state-of-the-art analog-SiPMs and scintillation materials. The intrinsic SiPM single photon time resolution (SPTR) was measured with Ketek, HPK, FBK, SensL and Broadcom devices. Also, the best achieved coincidence time resolution (CTR) for these devices was measured with LSO:Ce:Ca of mm 3 and mm 3 size crystals. The intrinsic SPTR for all devices ranges between 70 ps and 135 ps FWHM when illuminating the entire mm 2 or mm 2 area. The obtained CTR with LSO:Ce:Ca of mm 3 size ranges between 58 ps and 76 ps FWHM for the SiPMs evaluated. Bismuth Germanate (BGO), read out with state of-the-art NUV-HD SiPMs from FBK, achieved a CTR of 158 ps and 277 ps FWHM for mm 3 and mm 3 crystals, respectively. Other BGO geometries yielded 167 3 ps FWHM for mm 3 and 235 5 ps FWHM for mm 3 also coupled with Meltmount (n = 1.582) and wrapped in Teflon. Additionally, the average number of Cherenkov photons produced by BGO in each 511 keV event was measured to be 17 3 photons. Based on this measurement, we predict the limits of BGO for ultrafast timing in TOF-PET with Monte Carlo simulations. Plastic scintillators (BC422, BC418), BaF 2, GAGG:Ce codoped with Mg and CsI:undoped were also tested for TOF performance. Indeed, BC422 can achieve a CTR of 35 2 ps FWHM using only Compton interactions in the detector with a maximum deposited energy of 340 keV. BaF 2 with its fast cross-luminescence enables a CTR of 51 5 ps FWHM when coupled to VUV-HD SiPMs from FBK, with only ∼22% photon detection efficiency (PDE). We summarize the measured CTR of the various scintillators and discuss their intrinsic timing performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pushing the Limits in Time-of-Flight PET Imaging
Lecoq, P. (2017) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2017.2756674 · Cited by 302
Self-citationNUV-Sensitive Silicon Photomultiplier Technologies Developed at Fondazione Bruno Kessler
Gola, A. G., Acerbi, F., Capasso, M., Marcante, M., Mazzi, A., Paternoster, G., Piemonte, C., Regazzoni, V., & Zorzi, N. (2019) · Sensors · doi:10.3390/s19020308 · Cited by 216
The new opportunities for high time resolution clinical TOF PET
Conti, M., & Bendriem, B. (2019) · Clinical and Translational Imaging · doi:10.1007/s40336-019-00316-5 · Cited by 180
Gundacker, S., Auffray, E., Pauwels, K., & Lecoq, P. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/7/2802 · Cited by 173
Self-citationBGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET
Brünner, S., & Schaart, D. R. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6a49 · Cited by 173
Gundacker, S., Acerbi, F., Auffray, E., Ferri, A., Gola, A. G., Nemallapudi, M. V., Paternoster, G., Piemonte, C., & Lecoq, P. R. (2016) · Journal of Instrumentation · doi:10.1088/1748-0221/11/08/p08008 · Cited by 155
Self-citationGarutti, E., & Musienko, Y. (2019) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.10.191 · Cited by 145
Cates, J. W., Gundacker, S., Auffray, E., Lecoq, P. R., & Levin, C. S. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aadbcd · Cited by 123
Self-citationPerformance of NUV-HD Silicon Photomultiplier Technology
Piemonte, C., Acerbi, F., Ferri, A., Gola, A. G., Paternoster, G., Regazzoni, V., Zappalà, G., & Zorzi, N. (2016) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2016.2516641 · Cited by 122
On the use of CdSe scintillating nanoplatelets as time taggers for high-energy gamma detection
Turtos, R. M., Gundacker, S., Omelkov, S. I., Mahler, B., Khan, A. H., Saaring, J., Meng, Z., Васильев, А. Н., Dujardin, C., Kirm, M., et al. (2019) · npj 2D Materials and Applications · doi:10.1038/s41699-019-0120-8 · Cited by 100
Self-citationBismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET
Kwon, S. I., Gola, A. G., Ferri, A., Piemonte, C., & Cherry, S. R. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/l38 · Cited by 94
Electronics method to advance the coincidence time resolution with bismuth germanate
Cates, J. W., & Levin, C. S. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab31e3 · Cited by 68
Efthimiou, N., Thielemans, K., Emond, E. C., Cawthorne, C., Archibald, S. J., & Tsoumpas, C. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00309-8 · Cited by 23
Cited by
Roadmap toward the 10 ps time-of-flight PET challenge
Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab9500 · Cited by 258
Self-citationThe silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector
Gundacker, S., & Heering, A. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab7b2d · Cited by 237
“This is illustrated in figure 19 by comprehensive Monte-Carlo simulations (Gundacker et al 2016b, Gundacker et al 2020).”
BackgroundMethodInfluentialSelf-citationPositronium imaging with the novel multiphoton PET scanner
Moskal, P., Dulski, K., Chug, N., Curceanu, C., Czerwiński, E., Dadgar, M., Gajewski, J., Gajos, A., Grudzień, G., Hiesmayr, B. C., et al. (2021) · Science Advances · doi:10.1126/sciadv.abh4394 · Cited by 180
“This could result in a further improvement, even up to 10 ps (54, 55, 57); thus, it could create positronium images with a spatial resolution of 0.”
Update on latest advances in time-of-flight PET
Surti, S., & Karp, J. S. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.10.031 · Cited by 96
Metadata
- Authors
- Gundacker, S., Martinez Turtos, R., Kratochwil, N., Pots, R. H., Paganoni, M., Lecoq, P., & Auffray, E.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2020-01-01
- Volume
- 65
- Issue
- 2
- Pages
- 025001
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2995392475
- Cited by
- 265
- References
- 13
- FWCI
- 24.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.