CoChat

An unsupervised 2D–3D deformable registration network (2D3D-RegNet) for cone-beam CT estimation

Zhang, You · 2021 · Physics in Medicine & Biology
Cited by 33

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Acquiring CBCTs from a limited scan angle can help to reduce the imaging time, save the imaging dose, and allow continuous target localizations through arc-based treatments with high temporal resolution. However, insufficient scan angle sampling leads to severe distortions and artifacts in the reconstructed CBCT images, limiting their clinical applicability. 2D–3D deformable registration can map a prior fully-sampled CT/CBCT volume to estimate a new CBCT, based on limited-angle on-board cone-beam projections. The resulting CBCT images estimated by 2D–3D deformable registration can successfully suppress the distortions and artifacts, and reflect up-to-date patient anatomy. However, traditional iterative 2D–3D deformable registration algorithm is very computationally expensive and time-consuming, which takes hours to generate a high quality deformation vector field (DVF) and the CBCT. In this work, we developed an unsupervised, end-to-end, 2D–3D deformable registration framework using convolutional neural networks (2D3D-RegNet) to address the speed bottleneck of the conventional iterative 2D–3D deformable registration algorithm. The 2D3D-RegNet was able to solve the DVFs within 5 seconds for 90 orthogonally-arranged projections covering a combined 90° scan angle, with DVF accuracy superior to 3D–3D deformable registration, and on par with the conventional 2D–3D deformable registration algorithm. We also performed a preliminary robustness analysis of 2D3D-RegNet towards projection angular sampling frequency variations, as well as scan angle offsets. The synergy of 2D3D-RegNet with biomechanical modeling was also evaluated, and demonstrated that 2D3D-RegNet can function as a fast DVF solution core for further DVF refinement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6560/abe9f6

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 48

  1. Balakrishnan, 2019, Voxelmorph: a learning framework for deformable medical image registration, IEEE Trans. Med. Imaging, 38, 1788, 10.1109/TMI.2019.2897538 · DOI · Paper page
  2. Ballhausen, 2018, Shorter treatment times reduce the impact of intra-fractional motion : a real-time 4DUS study comparing VMAT versus step-and-shoot IMRT for prostate cancer, Strahlenther. Onkol., 194, 664, 10.1007/s00066-018-1286-2 · doi:10.1007/s00066-018-1286-2
  3. Biguri, 2017, A general method for motion compensation in x-ray computed tomography, Phys. Med. Biol., 62, 6532, 10.1088/1361-6560/aa7675 · DOI
  4. Brock, 2010, Reconstruction of a cone-beam CT image via forward iterative projection matching, Med. Phys., 37, 6212, 10.1118/1.3515460 · DOI
  5. Chen, 2008, A simple fixed-point approach to invert a deformation field, Med. Phys., 35, 81, 10.1118/1.2816107 · DOI
  6. Chen, 2017, Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction, Med. Phys., 44, e215, 10.1002/mp.12326 · DOI
  7. Dang, 2016, Simultaneous 4D-CBCT reconstruction with sliding motion constraint, Med. Phys., 43, 5453, 10.1118/1.4959998 · DOI
  8. Davison, 1983, The Ill-Conditioned nature of the limited angle tomography problem, SIAM J. Appl. Math., 43, 428, 10.1137/0143028 · DOI
  9. Eppenhof, 2018, Pulmonary CT registration through supervised learning with convolutional neural networks, IEEE Trans. Med. Imaging, 38, 1097, 10.1109/TMI.2018.2878316 · DOI · Paper page
  10. Feldkamp, 1984, Practical cone-beam algorithm, J. Opt. Soc. Am. A, 1, 612, 10.1364/JOSAA.1.000612 · DOI · Paper page
  11. Frikel, 2013, Characterization and reduction of artifacts in limited angle tomography, Inverse Problems, 29, 10.1088/0266-5611/29/12/125007 · doi:10.1088/0266-5611/29/12/125007
  12. Fu, 2020, LungRegNet: an unsupervised deformable image registration method for 4D-CT lung, Med. Phys., 47, 1763, 10.1002/mp.14065 · DOI · Paper page
  13. Gobbi, 2003, Generalized 3D nonlinear transformations for medical imaging: an object-oriented implementation in VTK, Comput. Med. Imaging Graph., 27, 255, 10.1016/S0895-6111(02)00091-5 · doi:10.1016/s0895-6111(02)00091-5
  14. Hansen, 2018, ScatterNet: a convolutional neural network for cone-beam CT intensity correction, Med. Phys., 45, 4916, 10.1002/mp.13175 · DOI
  15. Hugo, 2016, A longitudinal four‐dimensional computed tomography and cone beam computed tomography dataset for image‐guided radiation therapy research in lung cancer, Med. Phys., 44, 762, 10.1002/mp.12059 · DOI
  16. Jaffray, 2000, Cone-beam computed tomography with a flat-panel imager: initial performance characterization, Med. Phys., 27, 1311, 10.1118/1.599009 · doi:10.1118/1.599009
  17. Jiang, 2020, A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration, Phys. Med. Biol., 65, 015011, 10.1088/1361-6560/ab5da0 · DOI · Paper page
  18. Keall, 2006, The management of respiratory motion in radiation oncology report of AAPM task group 76, Med. Phys., 33, 3874, 10.1118/1.2349696 · DOI · Paper page
  19. Kerner, 2015, Evaluation of elastix-based propagated align algorithm for VOI-and voxel-based analysis of longitudinal 18 F-FDG PET/CT data from patients with non-small cell lung cancer (NSCLC), EJNMMI Res., 5, 15, 10.1186/s13550-015-0089-z · doi:10.1186/s13550-015-0089-z
  20. Liu, 2014, Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy, Med. Phys., 41, 031710, 10.1118/1.4866222 · doi:10.1118/1.4866222
  21. Lu, 2004, Fast free-form deformable registration via calculus of variations, Phys. Med. Biol., 49, 3067, 10.1088/0031-9155/49/14/003 · DOI · Paper page
  22. Marchant, 2018, Accuracy of radiotherapy dose calculations based on cone-beam CT: comparison of deformable registration and image correction based methods, Phys. Med. Biol., 63, 065003, 10.1088/1361-6560/aab0f0 · DOI
  23. Myronenko, 2010, Intensity-based image registration by minimizing residual complexity, IEEE Trans. Med. Imaging, 29, 1882, 10.1109/TMI.2010.2053043 · DOI · Paper page
  24. Ouadah, 2017, Correction of patient motion in cone-beam CT using 3D–2D registration, Phys. Med. Biol., 62, 8813, 10.1088/1361-6560/aa9254 · DOI
  25. Purdie, 2007, Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position, Int. J. Radiat. Oncol. Biol. Phys., 68, 243, 10.1016/j.ijrobp.2006.12.022 · DOI
  26. Ren, 2016, Scatter reduction and correction for dual-source cone-beam CT using prepatient grids, Technol. Cancer Res. Treat., 15, 416, 10.1177/1533034615587615 · DOI
  27. Ren, 2012, Development and clinical evaluation of a three-dimensional cone-beam computed tomography estimation method using a deformation field map, Int. J. Radiat. Oncol. Biol. Phys., 82, 1584, 10.1016/j.ijrobp.2011.02.002 · doi:10.1016/j.ijrobp.2011.02.002
  28. Ren, 2014, A limited-angle intrafraction verification (LIVE) system for radiation therapy, Med. Phys., 41, 020701, 10.1118/1.4861820 · DOI
  29. Rivenson, 2018, Phase recovery and holographic image reconstruction using deep learning in neural networks, Light: Sci. Appl., 7, 17141, 10.1038/lsa.2017.141 · DOI · Paper page
  30. Siddon, 1985a, Fast calculation of the exact radiological path for a three-dimensional CT array, Med. Phys., 12, 252, 10.1118/1.595715 · DOI · Paper page
  31. Siddon, 1985b, Prism representation: a 3D ray-tracing algorithm for radiotherapy applications, Phys. Med. Biol., 30, 817, 10.1088/0031-9155/30/8/005 · doi:10.1088/0031-9155/30/8/005
  32. Syben, 2019a, PYRO-NN: python reconstruction operators in neural networks, Med. Phys., 46, 5110, 10.1002/mp.13753 · DOI
  33. Syben, 2019b, Technical note: PYRO-NN: python reconstruction operators in neural networks, Med. Phys., 46, 5110, 10.1002/mp.13753 · DOI
  34. Thing, 2013, Patient-specific scatter correction in clinical cone beam computed tomography imaging made possible by the combination of Monte Carlo simulations and a ray tracing algorithm, Acta Oncol., 52, 1477, 10.3109/0284186X.2013.813641 · DOI
  35. Vandemeulebroucke, 2011, Spatiotemporal motion estimation for respiratory-correlated imaging of the lungs, Med. Phys., 38, 166, 10.1118/1.3523619 · DOI · Paper page
  36. Viola, 1997, Alignment by maximization of mutual information, Int. J. Comput. Vis., 24, 137, 10.1023/A:1007958904918 · DOI · Paper page
  37. Wang, 2012, High-quality four-dimensional cone-beam CT by deforming prior images, Phys. Med. Biol., 58, 231, 10.1088/0031-9155/58/2/231 · DOI
  38. Wang, 2013, Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT, Med. Phys., 40, 101912, 10.1118/1.4821099 · DOI
  39. Werner, 2009, Patient-specific finite element modeling of respiratory lung motion using 4D CT image data, Med. Phys., 36, 1500, 10.1118/1.3101820 · DOI · Paper page
  40. Wurfl, 2018, Deep learning computed tomography: learning projection-domain weights from image domain in limited angle problems, IEEE Trans. Med. Imaging, 37, 1454, 10.1109/TMI.2018.2833499 · DOI · Paper page
  41. Yan, 1997, Adaptive radiation therapy, Phys. Med. Biol., 42, 123, 10.1088/0031-9155/42/1/008 · DOI · Paper page
  42. Zhang, 2019, 4D liver tumor localization using cone-beam projections and a biomechanical model, Radiother. Oncol., 133, 183, 10.1016/j.radonc.2018.10.040 · DOI
  43. Zhang, 2013a, Respiration-phase-matched digital tomosynthesis imaging for moving target verification: a feasibility study, Med. Phys., 40, 071723, 10.1118/1.4810921 · doi:10.1118/1.4810921
  44. Zhang, 2017, Clinical study of orthogonal-view phase-matched digital tomosynthesis for lung tumor localization, Technol. Cancer Res. Treat., 16, 866, 10.1177/1533034617705716 · DOI
  45. Zhang, 2016b, A biomechanical modeling guided CBCT estimation technique, IEEE Trans. Med. Imaging, 36, 641, 10.1109/TMI.2016.2623745 · DOI
  46. Zhang, 2015b, Dosimetric verification of lung cancer treatment using the CBCTs estimated from limited-angle on-board projections, Med. Phys., 42, 4783, 10.1118/1.4926559 · doi:10.1118/1.4926559
  47. Zhang, 2015a, Preliminary clinical evaluation of a 4D-CBCT estimation technique using prior information and limited-angle projections, Radiother. Oncol., 115, 22, 10.1016/j.radonc.2015.02.022 · DOI
  48. Zhang, 2013b, A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections, Med. Phys., 40, 121701, 10.1118/1.4825097 · DOI

Cited by

Metadata

Authors
Zhang, Y.
Affiliations
Advanced Imaging and Informatics for Radiation Therapy (AIRT) Laboratory, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX 75235,
Venue
Physics in Medicine & Biology
Published
2021-03-24
Volume
66
Issue
7
Pages
074001
ISSN
  • 0031-9155
  • 1361-6560
Cited by
33
References
5
Licence
Funders
  • UT Southwestern Medical Center Seed Grant
  • National Institutes of Health (R01 CA240808)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.