An unsupervised 2D–3D deformable registration network (2D3D-RegNet) for cone-beam CT estimation
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Acquiring CBCTs from a limited scan angle can help to reduce the imaging time, save the imaging dose, and allow continuous target localizations through arc-based treatments with high temporal resolution. However, insufficient scan angle sampling leads to severe distortions and artifacts in the reconstructed CBCT images, limiting their clinical applicability. 2D–3D deformable registration can map a prior fully-sampled CT/CBCT volume to estimate a new CBCT, based on limited-angle on-board cone-beam projections. The resulting CBCT images estimated by 2D–3D deformable registration can successfully suppress the distortions and artifacts, and reflect up-to-date patient anatomy. However, traditional iterative 2D–3D deformable registration algorithm is very computationally expensive and time-consuming, which takes hours to generate a high quality deformation vector field (DVF) and the CBCT. In this work, we developed an unsupervised, end-to-end, 2D–3D deformable registration framework using convolutional neural networks (2D3D-RegNet) to address the speed bottleneck of the conventional iterative 2D–3D deformable registration algorithm. The 2D3D-RegNet was able to solve the DVFs within 5 seconds for 90 orthogonally-arranged projections covering a combined 90° scan angle, with DVF accuracy superior to 3D–3D deformable registration, and on par with the conventional 2D–3D deformable registration algorithm. We also performed a preliminary robustness analysis of 2D3D-RegNet towards projection angular sampling frequency variations, as well as scan angle offsets. The synergy of 2D3D-RegNet with biomechanical modeling was also evaluated, and demonstrated that 2D3D-RegNet can function as a fast DVF solution core for further DVF refinement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“PolyPose outperforms both deep learning-based 2D/3D methods [18, 19]”
From PolyPose: Deformable 2D/3D Registration via Polyrigid Transformations (2025) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Willmott, C., & Matsuura, K. (2005) · Climate Research · doi:10.3354/cr030079 · Cited by 7,958
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Mean squared error: Love it or leave it? A new look at Signal Fidelity Measures
Wang, Z., & Bovik, A. C. (2009) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.930649 · Cited by 3,175
Interactive medical image segmentation using deep learning with image-specific fine tuning
Wang, G., Li, W., Zuluaga, M. A., Pratt, R., Patel, P. A., Aertsen, M., Doel, T., David, A. L., Deprest, J., Ourselin, S., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2791721 · Cited by 843
A CNN Regression Approach for Real-Time 2D/3D Registration
Miao, S., Wang, Z. J., & Liao, R. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2521800 · Cited by 514
Research works printed but not linked: 48
- Balakrishnan, 2019, Voxelmorph: a learning framework for deformable medical image registration, IEEE Trans. Med. Imaging, 38, 1788, 10.1109/TMI.2019.2897538 · DOI · Paper page
- Ballhausen, 2018, Shorter treatment times reduce the impact of intra-fractional motion : a real-time 4DUS study comparing VMAT versus step-and-shoot IMRT for prostate cancer, Strahlenther. Onkol., 194, 664, 10.1007/s00066-018-1286-2 · doi:10.1007/s00066-018-1286-2
- Biguri, 2017, A general method for motion compensation in x-ray computed tomography, Phys. Med. Biol., 62, 6532, 10.1088/1361-6560/aa7675 · DOI
- Brock, 2010, Reconstruction of a cone-beam CT image via forward iterative projection matching, Med. Phys., 37, 6212, 10.1118/1.3515460 · DOI
- Chen, 2008, A simple fixed-point approach to invert a deformation field, Med. Phys., 35, 81, 10.1118/1.2816107 · DOI
- Chen, 2017, Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction, Med. Phys., 44, e215, 10.1002/mp.12326 · DOI
- Dang, 2016, Simultaneous 4D-CBCT reconstruction with sliding motion constraint, Med. Phys., 43, 5453, 10.1118/1.4959998 · DOI
- Davison, 1983, The Ill-Conditioned nature of the limited angle tomography problem, SIAM J. Appl. Math., 43, 428, 10.1137/0143028 · DOI
- Eppenhof, 2018, Pulmonary CT registration through supervised learning with convolutional neural networks, IEEE Trans. Med. Imaging, 38, 1097, 10.1109/TMI.2018.2878316 · DOI · Paper page
- Feldkamp, 1984, Practical cone-beam algorithm, J. Opt. Soc. Am. A, 1, 612, 10.1364/JOSAA.1.000612 · DOI · Paper page
- Frikel, 2013, Characterization and reduction of artifacts in limited angle tomography, Inverse Problems, 29, 10.1088/0266-5611/29/12/125007 · doi:10.1088/0266-5611/29/12/125007
- Fu, 2020, LungRegNet: an unsupervised deformable image registration method for 4D-CT lung, Med. Phys., 47, 1763, 10.1002/mp.14065 · DOI · Paper page
- Gobbi, 2003, Generalized 3D nonlinear transformations for medical imaging: an object-oriented implementation in VTK, Comput. Med. Imaging Graph., 27, 255, 10.1016/S0895-6111(02)00091-5 · doi:10.1016/s0895-6111(02)00091-5
- Hansen, 2018, ScatterNet: a convolutional neural network for cone-beam CT intensity correction, Med. Phys., 45, 4916, 10.1002/mp.13175 · DOI
- Hugo, 2016, A longitudinal four‐dimensional computed tomography and cone beam computed tomography dataset for image‐guided radiation therapy research in lung cancer, Med. Phys., 44, 762, 10.1002/mp.12059 · DOI
- Jaffray, 2000, Cone-beam computed tomography with a flat-panel imager: initial performance characterization, Med. Phys., 27, 1311, 10.1118/1.599009 · doi:10.1118/1.599009
- Jiang, 2020, A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration, Phys. Med. Biol., 65, 015011, 10.1088/1361-6560/ab5da0 · DOI · Paper page
- Keall, 2006, The management of respiratory motion in radiation oncology report of AAPM task group 76, Med. Phys., 33, 3874, 10.1118/1.2349696 · DOI · Paper page
- Kerner, 2015, Evaluation of elastix-based propagated align algorithm for VOI-and voxel-based analysis of longitudinal 18 F-FDG PET/CT data from patients with non-small cell lung cancer (NSCLC), EJNMMI Res., 5, 15, 10.1186/s13550-015-0089-z · doi:10.1186/s13550-015-0089-z
- Liu, 2014, Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy, Med. Phys., 41, 031710, 10.1118/1.4866222 · doi:10.1118/1.4866222
- Lu, 2004, Fast free-form deformable registration via calculus of variations, Phys. Med. Biol., 49, 3067, 10.1088/0031-9155/49/14/003 · DOI · Paper page
- Marchant, 2018, Accuracy of radiotherapy dose calculations based on cone-beam CT: comparison of deformable registration and image correction based methods, Phys. Med. Biol., 63, 065003, 10.1088/1361-6560/aab0f0 · DOI
- Myronenko, 2010, Intensity-based image registration by minimizing residual complexity, IEEE Trans. Med. Imaging, 29, 1882, 10.1109/TMI.2010.2053043 · DOI · Paper page
- Ouadah, 2017, Correction of patient motion in cone-beam CT using 3D–2D registration, Phys. Med. Biol., 62, 8813, 10.1088/1361-6560/aa9254 · DOI
- Purdie, 2007, Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position, Int. J. Radiat. Oncol. Biol. Phys., 68, 243, 10.1016/j.ijrobp.2006.12.022 · DOI
- Ren, 2016, Scatter reduction and correction for dual-source cone-beam CT using prepatient grids, Technol. Cancer Res. Treat., 15, 416, 10.1177/1533034615587615 · DOI
- Ren, 2012, Development and clinical evaluation of a three-dimensional cone-beam computed tomography estimation method using a deformation field map, Int. J. Radiat. Oncol. Biol. Phys., 82, 1584, 10.1016/j.ijrobp.2011.02.002 · doi:10.1016/j.ijrobp.2011.02.002
- Ren, 2014, A limited-angle intrafraction verification (LIVE) system for radiation therapy, Med. Phys., 41, 020701, 10.1118/1.4861820 · DOI
- Rivenson, 2018, Phase recovery and holographic image reconstruction using deep learning in neural networks, Light: Sci. Appl., 7, 17141, 10.1038/lsa.2017.141 · DOI · Paper page
- Siddon, 1985a, Fast calculation of the exact radiological path for a three-dimensional CT array, Med. Phys., 12, 252, 10.1118/1.595715 · DOI · Paper page
- Siddon, 1985b, Prism representation: a 3D ray-tracing algorithm for radiotherapy applications, Phys. Med. Biol., 30, 817, 10.1088/0031-9155/30/8/005 · doi:10.1088/0031-9155/30/8/005
- Syben, 2019a, PYRO-NN: python reconstruction operators in neural networks, Med. Phys., 46, 5110, 10.1002/mp.13753 · DOI
- Syben, 2019b, Technical note: PYRO-NN: python reconstruction operators in neural networks, Med. Phys., 46, 5110, 10.1002/mp.13753 · DOI
- Thing, 2013, Patient-specific scatter correction in clinical cone beam computed tomography imaging made possible by the combination of Monte Carlo simulations and a ray tracing algorithm, Acta Oncol., 52, 1477, 10.3109/0284186X.2013.813641 · DOI
- Vandemeulebroucke, 2011, Spatiotemporal motion estimation for respiratory-correlated imaging of the lungs, Med. Phys., 38, 166, 10.1118/1.3523619 · DOI · Paper page
- Viola, 1997, Alignment by maximization of mutual information, Int. J. Comput. Vis., 24, 137, 10.1023/A:1007958904918 · DOI · Paper page
- Wang, 2012, High-quality four-dimensional cone-beam CT by deforming prior images, Phys. Med. Biol., 58, 231, 10.1088/0031-9155/58/2/231 · DOI
- Wang, 2013, Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT, Med. Phys., 40, 101912, 10.1118/1.4821099 · DOI
- Werner, 2009, Patient-specific finite element modeling of respiratory lung motion using 4D CT image data, Med. Phys., 36, 1500, 10.1118/1.3101820 · DOI · Paper page
- Wurfl, 2018, Deep learning computed tomography: learning projection-domain weights from image domain in limited angle problems, IEEE Trans. Med. Imaging, 37, 1454, 10.1109/TMI.2018.2833499 · DOI · Paper page
- Yan, 1997, Adaptive radiation therapy, Phys. Med. Biol., 42, 123, 10.1088/0031-9155/42/1/008 · DOI · Paper page
- Zhang, 2019, 4D liver tumor localization using cone-beam projections and a biomechanical model, Radiother. Oncol., 133, 183, 10.1016/j.radonc.2018.10.040 · DOI
- Zhang, 2013a, Respiration-phase-matched digital tomosynthesis imaging for moving target verification: a feasibility study, Med. Phys., 40, 071723, 10.1118/1.4810921 · doi:10.1118/1.4810921
- Zhang, 2017, Clinical study of orthogonal-view phase-matched digital tomosynthesis for lung tumor localization, Technol. Cancer Res. Treat., 16, 866, 10.1177/1533034617705716 · DOI
- Zhang, 2016b, A biomechanical modeling guided CBCT estimation technique, IEEE Trans. Med. Imaging, 36, 641, 10.1109/TMI.2016.2623745 · DOI
- Zhang, 2015b, Dosimetric verification of lung cancer treatment using the CBCTs estimated from limited-angle on-board projections, Med. Phys., 42, 4783, 10.1118/1.4926559 · doi:10.1118/1.4926559
- Zhang, 2015a, Preliminary clinical evaluation of a 4D-CBCT estimation technique using prior information and limited-angle projections, Radiother. Oncol., 115, 22, 10.1016/j.radonc.2015.02.022 · DOI
- Zhang, 2013b, A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections, Med. Phys., 40, 121701, 10.1118/1.4825097 · DOI
Cited by
PolyPose: Deformable 2D/3D Registration via Polyrigid Transformations
Gopalakrishnan, V., Dey, N., & Golland, P. (2025) · Advances in Neural Information Processing Systems 38 · doi:10.52202/085713-2026 · Cited by 3
Metadata
- Authors
- Zhang, Y.
- Affiliations
- Advanced Imaging and Informatics for Radiation Therapy (AIRT) Laboratory, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX 75235,
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2021-03-24
- Volume
- 66
- Issue
- 7
- Pages
- 074001
- ISSN
- 0031-9155
- 1361-6560
- Cited by
- 33
- References
- 5
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Funders
- UT Southwestern Medical Center Seed Grant
- National Institutes of Health (R01 CA240808)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.