Cited by 64Obstructive Sleep Apnea ResearchNon-Invasive Vital Sign MonitoringSleep and related disorders

The DOI matches its Crossref record; 226 of the 233 references it cites were found in a registry or an index, and 1 are not checked yet.

Sleep apnea: a review of diagnostic sensors, algorithms, and therapies

Open access

Abstract

While public awareness of sleep related disorders is growing, sleep apnea syndrome (SAS) remains a public health and economic challenge. Over the last two decades, extensive controlled epidemiologic research has clarified the incidence, risk factors including the obesity epidemic, and global prevalence of obstructive sleep apnea (OSA), as well as establishing a growing body of literature linking OSA with cardiovascular morbidity, mortality, metabolic dysregulation, and neurocognitive impairment. The US Institute of Medicine Committee on Sleep Medicine estimates that 50-70 million US adults have sleep or wakefulness disorders. Furthermore, the American Academy of Sleep Medicine (AASM) estimates that more than 29 million US adults suffer from moderate to severe OSA, with an estimated 80% of those individuals living unaware and undiagnosed, contributing to more than $149.6 billion in healthcare and other costs in 2015. Although various devices have been used to measure physiological signals, detect apneic events, and help treat sleep apnea, significant opportunities remain to improve the quality, efficiency, and affordability of sleep apnea care. As our understanding of respiratory and neurophysiological signals and sleep apnea physiological mechanisms continues to grow, and our ability to detect and process biomedical signals improves, novel diagnostic and treatment modalities emerge. OBJECTIVE: This article reviews the current engineering approaches for the detection and treatment of sleep apnea. APPROACH: It discusses signal acquisition and processing, highlights the current nonsurgical and nonpharmacological treatments, and discusses potential new therapeutic approaches. MAIN RESULTS: This work has led to an array of validated signal and sensor modalities for acquiring, storing and viewing sleep data; a broad class of computational and signal processing approaches to detect and classify SAS disease patterns; and a set of distinctive therapeutic technologies whose use cases span the continuum of disease severity. SIGNIFICANCE: This review provides a current perspective of the classes of tools at hand, along with a sense of their relative strengths and areas for further improvement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6579/aa6ec6

Cites

226 of 227 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Items 201–227 of 227

Flagged first, then by citations

6 of the 233 references couldn’t be matched to a known paper.

Research works printed but not linked: 2

  1. Garg, 2011, Computer assisted automatic sleep scoring system using relative wavelet energy based neuro fuzzy model, WSEAS Trans. Biol. Biomed., 8, 12
  2. Kaguara, 2015, A deep neural network classifier for diagnosing sleep apnea from ECG data on smartphones and small embedded systems, 10.13140/2.1.4174.5448) · DOI

Cited by

Sorted by citations

See all 64

Metadata

Authors
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., Teodorescu, M., Dempsey, J., & Webster, J.
Affiliations
  • University of Wisconsin–Madison (US)
  • University of Minnesota (US)
Corresponding author
  • Shokoueinejad, Mehdi
  • Webster, John
Venue
Physiological Measurement
Published
2017-08-18
Volume
38
Issue
9
Pages
R204-R252
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2750410834
Cited by
64
References
233
Citations by year
2026: 7 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 10 · 2021: 4 · 2020: 11 · 2019: 9 · 2018: 9 · 2017: 3
FWCI
1.07
Type
journal article
Language
en
Open access
Locations
  • Physiological Measurement (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
obstructive sleep apnea, sleep apnea, sleep apnea diagnosis, sleep apnea treatment, physiological signal acquisition, biomedical sensors, signal processing, non-pharmacological treatment, cardiovascular risk, obesity, health care costs, undiagnosed sleep apnea
MeSH terms
Algorithms, Humans, Signal Processing, Computer-Assisted, Sleep Apnea Syndromes, Diagnostic Equipment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review