Estimating blood pressure trends and the nocturnal dip from photoplethysmography
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Objective . Evaluate a method for the estimation of the nocturnal systolic blood pressure (SBP) dip from 24 h blood pressure trends using a wrist-worn photoplethysmography (PPG) sensor and a deep neural network in free-living individuals, comparing the deep neural network to traditional machine learning and non-machine learning baselines. Approach . A wrist-worn PPG sensor was worn by 106 healthy individuals for 226 d during which 5111 reference values for blood pressure (BP) were obtained with a 24 h ambulatory BP monitor and matched with the PPG sensor data. Features based on heart rate variability and pulse morphology were extracted from the PPG waveforms. Long- and short term memory (LSTM) networks, dense networks, random forests and linear regression models were trained and evaluated in their capability of tracking trends in BP, as well as the estimation of the SBP dip. Main results . Best performance for estimating the SBP dip were obtained with a deep LSTM neural network with a root mean squared error (RMSE) of 3.12 2.20 mmHg and a correlation of 0.69 . This dip was derived from trend estimates of BP which had an RMSE of 8.22 1.49 mmHg for systolic and 6.55 1.39 mmHg for diastolic BP (DBP). While other models had similar performance for the tracking of relative BP, they did not perform as well as the LSTM for the SBP dip. Significance : The work provides first evidence for the unobtrusive estimation of the nocturnal SBP dip, a highly prognostic clinical parameter. It is also the first to evaluate unobtrusive BP measurement in a large data set of unconstrained 24 h measurements in free-living individuals and provides evidence for the utility of LSTM models in this domain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
Roth, G. A., Abate, D., Abate, K. H., Abay, S. M., Abbafati, C., Abbasi, N., Abbastabar, H., Abd-Allah, F., Abdela, J., Abdelalim, A., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)32203-7 · Cited by 8,600
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Multiscale entropy analysis of biological signals
Costa, M., Goldberger, A. L., & Peng, C.-K. (2005) · Physical Review E · doi:10.1103/physreve.71.021906 · Cited by 2,482
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Prechelt, L. (1998) · Lecture Notes in Computer Science · doi:10.1007/3-540-49430-8_3 · Cited by 1,649
(2008) · doi:10.1145/1401132.1401152 · Cited by 1,575 · cited 2×
“The algorithm was designed in Keras [9] and compiled to the Nvidia CUDA language [38] through the Tensorflow interface [1] to be trained on a Graphical Processing Unit.”
BackgroundMethodOn the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · cited 1×
“Over the last decade, focus has shifted towards pulse morphology analysis [13] as a step away from PAT, inspired by physiological explanations of the dynamics in the pulse waveform.”
BackgroundToward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · cited 2×
“The main track of research is based on the Moens-Korteweg equations, which relate the propagation velocity of the blood pulse within arteries to BP [6,37,41].”
BackgroundMethod
Cited by
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
A survey on deep learning in medicine: Why, how and when?
Piccialli, F., Somma, V. D., Giampaolo, F., Cuomo, S., & Fortino, G. (2021) · Information Fusion · doi:10.1016/j.inffus.2020.09.006 · Cited by 348
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
“Furthermore, it may be possible to identify changes in BP from a single PPG without calibration [159], which could have utility in detecting clinical deteriorations, such as sepsis.”
PP-Net: A Deep Learning Framework for PPG-Based Blood Pressure and Heart Rate Estimation
Panwar, M., Gautam, A., Biswas, D., & Acharyya, A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2990864 · Cited by 237
“The studies performed by [30]–[31] have utilized the University of Queensland Vital Signs Database (32 surgical persons) and their own datasets [32], [34] respectively, wherein our proposed methodology performed better compared to these studies despite of having much larger and diverse population with CVD complication…”
MethodCuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Papini, G. B., Fonseca, P., van Gilst, M. M., Bergmans, J. W. M., Vullings, R., & Overeem, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-69935-7 · Cited by 90
Self-citation
Metadata
- Authors
- Radha, M., de Groot, K., Rajani, N., Wong, C. C. P., Kobold, N., Vos, V., Fonseca, P., Mastellos, N., Wark, P. A., Velthoven, N., Haakma, R., & Aarts, R. M.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2019-02-01
- Volume
- 40
- Issue
- 2
- Pages
- 025006
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2903610377
- Cited by
- 80
- References
- 15
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.