CoChat

Two-photon quantum walks in an elliptical direct-write waveguide array

Open access
Owens, J O, Broome, M A, Biggerstaff, D N, Goggin, M E, Fedrizzi, A, Linjordet, T, Ams, M, Marshall, G D, Twamley, J, Withford, M J, White, A G · 2011 · New Journal of Physics

The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index, and 1 are not checked yet; 11 of the 24 sources its claims cite were checked for support.

Abstract

Integrated optics provides an ideal testbed for the emulation of quantum systems via continuous-time quantum walks. Here, we study the evolution of two-photon states in an elliptic array of waveguides. We characterize the photonic chip via coherent light tomography and use the results to predict distinct differences between temporally indistinguishable and distinguishable two-photon inputs, which we then compare with experimental observations. This work highlights the feasibility of emulation of coherent quantum phenomena in three-dimensional waveguide structures.

Verified 2026-11-25 · 1 reference not checked yet

Overview

CoChat Summary

TL;DR

The paper demonstrates two-photon continuous-time quantum walks in a six-waveguide elliptical direct-write fused-silica array, comparing temporally distinguishable and indistinguishable photon inputs. Coherent-light tomography predicts and experimentally confirms non-classical interference signatures, though the measured two-photon visibilities do not match predictions well.

Key findings

  • The chip supports two-photon quantum walks with distinct differences between distinguishable and indistinguishable inputs: for nearest-neighbour inputs 1 and 2, interference visibility was \(V = 38 \pm 2\%\), and generalized overlap fidelities were \(S_d = 93.4 \pm 0.3\%\) and \(S_i = 91.6 \pm 0.4\%\).
  • For next-nearest-neighbour inputs 2 and 4, non-classical interference visibilities up to \(V_{2,4} = 28 \pm 3\%\) were observed, with fidelities \(S_d = 97.9 \pm 1\%\) and \(S_i = 96.2 \pm 0.8\%\).
  • Coherent-light tomography revealed strong polarization effects: inputting \(|H\rangle\) into waveguide 5 rotated 29% of the overall output to \(|V\rangle\), while for channels 1, 2 and 4 more than 91% of \(|H\rangle\) was retained; for \(|H\rangle\) into waveguide 1, 80% of total output intensity was in channel 6, but for \(|V\rangle\) only 11% was in that channel.
  • The elliptical geometry produced non-negligible longer-range coupling: modelled coupling constants included \(C_{24}=0.963\ \mathrm{mm}^{-1}\), \(C_{12}=0.312\ \mathrm{mm}^{-1}\), \(C_{14}=0.050\ \mathrm{mm}^{-1}\), and \(C_{16}=0.044\ \mathrm{mm}^{-1}\), with \(C_{14}\) and \(C_{16}\) leading to modelled 40% and 33% coupling over the interaction length in isolation.

Methods

  • Six waveguides were written into high-purity fused silica using ultrafast direct-write laser techniques; inputs were spaced by 127 µm and converged via a two-stage fan-in to an ellipse with semi-major axis 10.2 µm and semi-minor axis 7.0 µm.
  • The chip was characterized with an 820 nm laser diode and polarization-sensitive coherent light tomography: six input polarizations into each waveguide and six measured output polarizations yielded 216 CCD images and a 36-element Mueller-matrix array.
  • Two-photon walks used SPDC photon pairs from a 76 MHz, 820 nm laser frequency-doubled to 410 nm and focused into a 2 mm type-I BBO crystal; photon pairs were created at 180 kHz and 6.5 kHz were detected at the circuit output. Measured coincidence distributions were compared with predictions from the waveguide array unitary \(U\).

Limitations

  • The paper states that the Mueller-matrix array derived from coherent beam intensities only yields the squared absolute values of the unitary \(U\) elements and does not determine the generally complex phase relations of the waveguide array.
  • The paper states that the measured two-photon visibilities matched predictions poorly, and that the resulting probability distributions did not exhibit a conclusively quantum signature as quantified by the witness in [16], most likely due to significant polarization-dependent coupling and loss causing non-unitary evolution.
  • The paper states that scaling to larger, more elaborate structures will make individual mode addressing tricky, and that unlike quantum simulation there are no known fault-tolerance or error-correction techniques for quantum emulation in quantum walks. Evident from the text: single-photon loss was about 73%, with main loss from poor input coupling between the V-groove array and chip (about 31%).

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1088/1367-2630/13/7/075003

Cites

33 of 34 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Schematic representation of the integrated waveguide circuit (drawing not-to-scale) and associated output. At the input the waveguides are equally spaced by 127 µ m. They then converge via a two-stage fan-in to their eventual elliptical configuration. The inset is a CCD image of the output: the waveguides are arranged with equal angular spacing around an ellipse with semi-major and semi-minor radii of 10.2 and 7 . 0 µ m, respectively.
Figure 1 Schematic representation of the integrated waveguide circuit (drawing not-to-scale) and associated output. At the input the waveguides are equally spaced by 127 µ m. They then converge via a two-stage fan-in to their eventual elliptical configuration. The inset is a CCD image of the output: the waveguides are arranged with equal angular spacing around an ellipse with semi-major and semi-minor radii of 10.2 and 7 . 0 µ m, respectively.CC-BY · From the PDF
Figure 2 Experimental setup. The chip can be addressed with six individual single-mode fibres. The input light polarization is set by a combination of halfand quarter-wave plates (HWP and QWP) and polarizing beamsplitters (PBS). The chip output is magnified and then collimated with two spherical lenses. (a) The chip was characterized with an 820 nm laser diode, imaged onto a CCD camera via a polarizing prism. (b) Quantum walks were performed with twophoton inputs created via spontaneous parametric downconversion (SPDC). The relative delay Delta1 z between the two input photons was adjusted using a translation stage. We used a 50 / 50 beamsplitter (BS) and two ∼ 500 µ m apertures to select a combination of output ports and measure the two-photon correlations in coincidence using single-photon avalanche diodes.
Figure 2 Experimental setup. The chip can be addressed with six individual single-mode fibres. The input light polarization is set by a combination of halfand quarter-wave plates (HWP and QWP) and polarizing beamsplitters (PBS). The chip output is magnified and then collimated with two spherical lenses. (a) The chip was characterized with an 820 nm laser diode, imaged onto a CCD camera via a polarizing prism. (b) Quantum walks were performed with twophoton inputs created via spontaneous parametric downconversion (SPDC). The relative delay Delta1 z between the two input photons was adjusted using a translation stage. We used a 50 / 50 beamsplitter (BS) and two ∼ 500 µ m apertures to select a combination of output ports and measure the two-photon correlations in coincidence using single-photon avalanche diodes.CC-BY · From the PDF
Figure 3 Comparison of numerical simulations and observed probability distributions for the optical chip in figure 1(a). The propagation dynamics predicted using optical waveguide simulation software (see the appendix) with light input into waveguide 1, as a function of z . The simulation includes modelling of inter-waveguide coupling during the 1 mm second fan-in stage at z ⩽ 0. The curves for waveguides 2 and 3, and 4 and 5 overlap due to symmetry. (b) The predicted distribution at the output of the circuit, and the corresponding observed probabilities. The asymmetry in the measured distribution indicates that the optical response of the chip is not scalar, instead suggesting some vectorial behaviour. This was confirmed by further tomographic analysis.
Figure 3 Comparison of numerical simulations and observed probability distributions for the optical chip in figure 1(a). The propagation dynamics predicted using optical waveguide simulation software (see the appendix) with light input into waveguide 1, as a function of z . The simulation includes modelling of inter-waveguide coupling during the 1 mm second fan-in stage at z ⩽ 0. The curves for waveguides 2 and 3, and 4 and 5 overlap due to symmetry. (b) The predicted distribution at the output of the circuit, and the corresponding observed probabilities. The asymmetry in the measured distribution indicates that the optical response of the chip is not scalar, instead suggesting some vectorial behaviour. This was confirmed by further tomographic analysis.CC-BY · From the PDF
Figure 4 Poincaré sphere representation of the corresponding Mueller matrices, M out , in (see the appendix), describing the transformation from input waveguide 6 to outputs 1-6. Input states shown on the outer Poincaré spheres are mapped to different locations on the blue ellipsoids, simultaneously showing polarizationdependent coupling and birefringent effects in the respective channel. The relative orientation of the ellipsoids is indicated by the set of orthogonal states | H 〉 (red arrow), | D 〉 (green arrow) and | R 〉 (black arrow), and the point of contact between the sphere and the ellipsoid is indicated by the yellow arrow. Note that the arrow lengths are proportional to output power, not degree of polarization. The numbers above each sphere give the normalized average power coupled into the respective channel.
Figure 4 Poincaré sphere representation of the corresponding Mueller matrices, M out , in (see the appendix), describing the transformation from input waveguide 6 to outputs 1-6. Input states shown on the outer Poincaré spheres are mapped to different locations on the blue ellipsoids, simultaneously showing polarizationdependent coupling and birefringent effects in the respective channel. The relative orientation of the ellipsoids is indicated by the set of orthogonal states | H 〉 (red arrow), | D 〉 (green arrow) and | R 〉 (black arrow), and the point of contact between the sphere and the ellipsoid is indicated by the yellow arrow. Note that the arrow lengths are proportional to output power, not degree of polarization. The numbers above each sphere give the normalized average power coupled into the respective channel.CC-BY · From the PDF
Figure 5 Example of observed two-photon interference between output waveguides 2 and 6 as a function of relative path difference between photon pairs input into neighbouring waveguides 1 and 2. The visibility of the dip is V 2 , 6 = 38 ± 2%, calculated from a Gaussian fit (blue line).
Figure 5 Example of observed two-photon interference between output waveguides 2 and 6 as a function of relative path difference between photon pairs input into neighbouring waveguides 1 and 2. The visibility of the dip is V 2 , 6 = 38 ± 2%, calculated from a Gaussian fit (blue line).CC-BY · From the PDF
Image 6
CC-BY · From the PDF
Figure 7 Correlation matrices for next-nearest neighbour input channels 2 and 4. The plots follow the same convention as those in figure 6, for both (a) the measured and (b) predicted correlation matrices. Uncertainties are again too small to be seen on the graphs.
Figure 7 Correlation matrices for next-nearest neighbour input channels 2 and 4. The plots follow the same convention as those in figure 6, for both (a) the measured and (b) predicted correlation matrices. Uncertainties are again too small to be seen on the graphs.CC-BY · From the PDF

Verification

Claims the paper makes

10 Valid · 4 Not valid · 7 Not checked · 37 Own results and interpretations

14 more claims

Create a free account to see all 58 claims and to verify the 1 reference still open.

See all claims — free account
  • Probably not a substantial claim. 23
  • It may state two separate claims as one. 16
  • The quote only partly states this claim. 2

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Cited by

See all 140

Metadata

Authors
Owens, J. O., Broome, M. A., Biggerstaff, D. N., Goggin, M. E., Fedrizzi, A., Linjordet, T., Ams, M., Marshall, G. D., Twamley, J., Withford, M. J., & White, A. G.
Affiliations
  • The University of Queensland (AU)
  • ARC Centre of Excellence for Engineered Quantum Systems (AU)
  • Centre for Ultrahigh Bandwidth Devices for Optical Systems (AU)
Corresponding author
Fedrizzi, A
Venue
New Journal of Physics
Published
2011-07-13
Volume
13
Issue
7
Pages
075003
ISSN
1367-2630 (ISSN-L)
OpenAlex
W2119350624
Cited by
135
References
31
Citations by year
2026: 2 · 2025: 2 · 2024: 8 · 2023: 2 · 2022: 3 · 2021: 7 · 2020: 6 · 2019: 9 · 2018: 3 · 2017: 10 · 2016: 13 · 2015: 18 · 2014: 13 · 2013: 18 · 2012: 20
FWCI
14.47
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • New Journal of Physics (publishedVersion, cc-by)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • Intelligence Advanced Research Projects Activity
  • Army Research Office
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Mechanics and Applications
Keywords
continuous-time quantum walks, integrated photonics, photon indistinguishability, quantum emulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.