CoChat

A low-cost, scalable, current-sensing digital headstage for high channel count μ ECoG

Open access
Trumpis, Michael, Insanally, Michele, Zou, Jialin, Elsharif, Ashraf, Ghomashchi, Ali, Sertac Artan, N, Froemke, Robert C, Viventi, Jonathan · 2017 · Journal of Neural Engineering
Cited by 23

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: High channel count electrode arrays allow for the monitoring of large-scale neural activity at high spatial resolution. Implantable arrays featuring many recording sites require compact, high bandwidth front-end electronics. In the present study, we investigated the use of a small, light weight, and low cost digital current-sensing integrated circuit for acquiring cortical surface signals from a 61-channel micro-electrocorticographic (μECoG) array. APPROACH: We recorded both acute and chronic μECoG signal from rat auditory cortex using our novel digital current-sensing headstage. For direct comparison, separate recordings were made in the same anesthetized preparations using an analog voltage headstage. A model of electrode impedance explained the transformation between current- and voltage-sensed signals, and was used to reconstruct cortical potential. We evaluated the digital headstage using several metrics of the baseline and response signals. MAIN RESULTS: The digital current headstage recorded neural signal with similar spatiotemporal statistics and auditory frequency tuning compared to the voltage signal. The signal-to-noise ratio of auditory evoked responses (AERs) was significantly stronger in the current signal. Stimulus decoding based on true and reconstructed voltage signals were not significantly different. Recordings from an implanted system showed AERs that were detectable and decodable for 52 d. The reconstruction filter mitigated the thermal current noise of the electrode impedance and enhanced overall SNR. SIGNIFICANCE: We developed and validated a novel approach to headstage acquisition that used current-input circuits to independently digitize 61 channels of μECoG measurements of the cortical field. These low-cost circuits, intended to measure photo-currents in digital imaging, not only provided a signal representing the local cortical field with virtually the same sensitivity and specificity as a traditional voltage headstage but also resulted in a small, light headstage that can easily be scaled to record from hundreds of channels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2552/aa5a82

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 23

Metadata

Authors
Trumpis, M., Insanally, M., Zou, J., Elsharif, A., Ghomashchi, A., Sertac Artan, N., Froemke, R. C., & Viventi, J.
Venue
Journal of Neural Engineering
Published
2017-02-08
Volume
14
Issue
2
Pages
026009
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2577809927
Cited by
23
References
12
FWCI
1.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A low-cost, scalable, current-sensing digital headstage for high channel count μ ECoG. https://app.cochat.ai/papers/10.1088/1741-2552/aa5a82
The paper
Trumpis, M., Insanally, M., Zou, J., Elsharif, A., Ghomashchi, A., Sertac Artan, N., Froemke, R. C., & Viventi, J. (2017). A low-cost, scalable, current-sensing digital headstage for high channel count μ ECoG. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/aa5a82

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.