Chronic cuffing of cervical vagus nerve inhibits efferent fiber integrity in rat model
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Numerous studies of vagal nerve stimulation (VNS) have been published showing it to be a potential treatment for chronic inflammation and other related diseases and disorders. Studies in recent years have shown that electrical stimulation of the vagal efferent fibers can artificially modulate cytokine levels and reduce systematic inflammation. Most VNS research in the treatment of inflammation have been acute studies on rodent subjects. Our study tested VNS on freely moving animals by stimulating and recording from the cervical vagus with nerve cuff electrodes over an extended period of time. APPROACH: We used methods of electrical stimulation, retrograde tracing (using Fluorogold) and post necropsy histological analysis of nerve tissue, flow cytometry to measure plasma cytokine levels, and MRI scanning of gastric emptying. This novel combination of methods allowed examination of physiological aspects of VNS previously unexplored. MAIN RESULTS: Through our study of 53 rat subjects, we found that chronically cuffing the left cervical vagus nerve suppressed efferent Fluorogold transport in 43 of 44 animals (36 showed complete suppression). Measured cytokine levels and gastric emptying rates concurrently showed nominal differences between chronically cuffed rats and those tested with similar acute methods. Meanwhile, results of electrophysiological and histological tests of the cuffed nerves revealed them to be otherwise healthy, consistent with previous literature. SIGNIFICANCE: We hypothesize that due to these unforeseen and unexplored physiological consequences of the chronically cuffed vagus nerve in a rat, that inflammatory modulation and other vagal effects by VNS may become unreliable in chronic studies. Given our findings, we submit that it would benefit the VNS community to re-examine methods used in previous literature to verify the efficacy of the rat model for chronic VNS studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acetylcholine-Synthesizing T Cells Relay Neural Signals in a Vagus Nerve Circuit
Rosas-Ballina, M., Olofsson, P. S., Ochani, M., Valdés-Ferrer, S. I., Levine, Y. A., Reardon, C., Tusche, M. W., Pavlov, V. A., Andersson, U., Chavan, S., et al. (2011) · Science · doi:10.1126/science.1209985 · Cited by 1,551
Koopman, F. A., Chavan, S. S., Miljko, S., Grazio, S., Sokolovic, S., Schuurman, P. R., Mehta, A. D., Levine, Y. A., Faltys, M., Zitnik, R., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605635113 · Cited by 1,024
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“This helical design has shown to be mechanically advantageous in reducing mechanical stresses directly to the nerve in human subjects [70].”
BackgroundThe cholinergic anti-inflammatory pathway: a missing link in neuroimmunomodulation
Pavlov, V. A., Wang, H., Czura, C. J., Friedman, S. G., & Tracey, K. J. (2003) · Molecular Medicine · doi:10.1007/bf03402177 · Cited by 772
Huston, J. M., Ochani, M., Rosas-Ballina, M., Liao, H., Ochani, K., Pavlov, V. A., Gallowitsch-Puerta, M., Ashok, M., Czura, C. J., Foxwell, B., et al. (2006) · The Journal of Experimental Medicine · doi:10.1084/jem.20052362 · Cited by 683
Bonaz, B., Sinniger, V., & Pellissier, S. (2016) · The Journal of Physiology · doi:10.1113/jp271539 · Cited by 561 · cited 1×
“These fibers serve many separate and distinct functions of the nervous system but are also connected within a parasympathetic system that contributes to the inflammatory reflex [12] and could cause possible conflicting effects between the two fiber types with VNS.”
BackgroundA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Vagal neurocircuitry and its influence on gastric motility
Travagli, R. A., & Anselmi, L. (2016) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2016.76 · Cited by 323
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207
Peña, D. F., Childs, J. E., Willett, S., Vital, A., McIntyre, C. K., & Kroener, S. (2014) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2014.00327 · Cited by 165
Cited by
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Hydrogel-based cardiac repair and regeneration function in the treatment of myocardial infarction
Xu, Q., Xiao, Z., Yang, Q., Yu, T., Deng, X., Chen, N., Huang, Y., Wang, L., Guo, J., & Wang, J. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.100978 · Cited by 77
“VNS has been used in drug-resistant epilepsy and depression and has been approved by the FDA [92,93].”
BackgroundMethodPrintable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35
“For example, traditional extra-neural cuff electrodes interface with intact whole nerves, but have limited recording capability and are a challenge to size properly for fine nerve targets (Loeb and Peck, 1996; Navarro et al., 2005; Somann et al., 2017).”
Background
Metadata
- Authors
- Somann, J. P., Albors, G. O., Neihouser, K. V., Lu, K.-H., Liu, Z., Ward, M. P., Durkes, A., Robinson, J. P., Powley, T. L., & Irazoqui, P. P.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2018-04-05
- Volume
- 15
- Issue
- 3
- Pages
- 036018
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2775371866
- Cited by
- 37
- References
- 13
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic cuffing of cervical vagus nerve inhibits efferent fiber integrity in rat model. https://app.cochat.ai/papers/10.1088/1741-2552/aaa039
- The paper
- Somann, J. P., Albors, G. O., Neihouser, K. V., Lu, K.-H., Liu, Z., Ward, M. P., Durkes, A., Robinson, J. P., Powley, T. L., & Irazoqui, P. P. (2018). Chronic cuffing of cervical vagus nerve inhibits efferent fiber integrity in rat model. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/aaa039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.