CoChat

A guide towards long-term functional electrodes interfacing neuronal tissue

Open access
Renz, Aline F, Reichmuth, Andreas M, Stauffer, Flurin, Thompson-Steckel, Greta, Vörös, Janos · 2018 · Journal of Neural Engineering
Cited by 50

The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.

Abstract

Implantable electronics address therapeutical needs of patients with electrical signaling dysfunctions such as heart problems, neurological disorders or hearing impairments. While standard electronics are rigid, planar and made of hard materials, their surrounding biological tissues are soft, wet and constantly in motion. These intrinsic differences in mechanical and chemical properties cause physiological responses that constitute a fundamental challenge to create functional long-term interfaces. Using soft and stretchable materials for electronic implants decreases the mechanical mismatch between implant and biological tissues. As a result, tissue damage during and after implantation is reduced, leading not only to an attenuated foreign body response, but also enabling completely novel applications. However, but for a few exceptions, soft materials are not sufficient to create long-term stable functional implants. In this work, we review recent progress in interfacing both the central (CNS) and peripheral nervous system (PNS) for long-term functional devices. The basics of soft and stretchable devices are introduced by highlighting the importance of minimizing physical as well as mechanical mismatch between tissue and implant in the CNS and emphasizing the relevance of an appropriate surface chemistry for implants in the PNS. Finally, we report on the latest materials and techniques that provide further electronic enhancements while reducing the foreign body reaction. Thus, this review should serve as a guide for creating long-term functional implants to enable future healthcare technologies and as a discussion on current ideas and progress within the field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2552/aae0c2

Cites

66 of 66 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 66 references

Cited by

See all 50

Metadata

Authors
Renz, A. F., Reichmuth, A. M., Stauffer, F., Thompson-Steckel, G., & Vörös, J.
Venue
Journal of Neural Engineering
Published
2018-10-16
Volume
15
Issue
6
Pages
061001
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2897988811
Cited by
50
References
66
FWCI
2.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A guide towards long-term functional electrodes interfacing neuronal tissue. https://app.cochat.ai/papers/10.1088/1741-2552/aae0c2
The paper
Renz, A. F., Reichmuth, A. M., Stauffer, F., Thompson-Steckel, G., & Vörös, J. (2018). A guide towards long-term functional electrodes interfacing neuronal tissue. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/aae0c2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.