Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The study of motor unit behavior has been classically performed by selective recording systems of muscle electrical activity (EMG signals) and decomposition algorithms able to discriminate between individual motor unit action potentials from multi-unit signals. In this study, we provide a general framework for the decomposition of multi-channel intramuscular and surface EMG signals and we extensively validate this approach with experimental recordings. APPROACH: First, we describe the conditions under which the assumptions of the convolutive blind separation model are satisfied. Second, we propose an approach of convolutive sphering of the observations followed by an iterative extraction of the sources. This approach is then validated using intramuscular signals recorded by novel multi-channel thin-film electrodes on the Abductor Digiti Minimi of the hand and Tibilias Anterior muscles, as well as on high-density surface EMG signals recorded by electrode grids on the First Dorsal Interosseous muscle. The validation was based on the comparison with the gold standard of manual decomposition (for intramuscular recordings) and on the two-source method (for comparison of intramuscular and surface EMG recordings) for the three human muscles and contraction forces of up to 90% MVC. MAIN RESULTS: The average number of common sources identified for the validation was 14 ± 7 (averaged across all trials and subjects and all comparisons), with a rate of agreement in their discharge timings of 92.8 ± 3.2%. The average Decomposability Index, calculated on the automatic decomposed signals, was 16.0 ± 2.2 (7.3-44.1). For comparison, the same index calculated on the manual decomposed signals was 15.0 ± 3.0 (6.3-76.6). SIGNIFICANCE: These results show that the method provides a solid framework for the decomposition of multi-channel invasive and non-invasive EMG signals that allows the study of the behavior of a large number of concurrently active motor units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Independent component analysis: algorithms and applications
Hyvärinen, A., & Oja, E. (2000) · Neural Networks · doi:10.1016/s0893-6080(00)00026-5 · Cited by 8,705
(2007) · doi:10.5555/1283383.1283494 · Cited by 7,364
Fast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246
A Fast Fixed-Point Algorithm for Independent Component Analysis
Hyvärinen, A., & Oja, E. (1997) · Neural Computation · doi:10.1162/neco.1997.9.7.1483 · Cited by 3,391
A blind source separation technique using second-order statistics
Belouchrani, A., Abed-Meraim, K., Cardoso, J.-F., & Moulines, E. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.554307 · Cited by 2,775
(2011) · Wiley eBooks · doi:10.1002/cphy · Cited by 1,505
Electromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Adrian, E. D., & Bronk, D. W. (1929) · The Journal of Physiology · doi:10.1113/jphysiol.1929.sp002557 · Cited by 787
Neuromechanics of Human Movement
Enoka, R. M. (2015) · Human Kinetics eBooks · doi:10.5040/9781492595632 · Cited by 703
Multichannel Blind Source Separation Using Convolution Kernel Compensation
Holobar, A., & Zazula, D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.896108 · Cited by 648
Self-citation
Cited by
Del Vecchio, A., Casolo, A., Negro, F., Scorcelletti, M., Bazzucchi, I., Enoka, R., Felici, F., & Farina, D. (2019) · The Journal of Physiology · doi:10.1113/jp277250 · Cited by 436
Self-citationTutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals
Del Vecchio, A., Holobar, A., Falla, D., Felici, F., Enoka, R. M., & Farina, D. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102426 · Cited by 372
Self-citationFarina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359
Self-citationDel Vecchio, A., Negro, F., Holobar, A., Casolo, A., Folland, J. P., Felici, F., & Farina, D. (2019) · The Journal of Physiology · doi:10.1113/jp277396 · Cited by 349
Self-citationCharacterization of Human Motor Units From Surface EMG Decomposition
Farina, D., & Holobar, A. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2498665 · Cited by 221
“Alternatively, it is possible to employ socalled source deflation procedures to decorrelate the estimated separation vectors and prevent the convergence to already identified sources [56], [80].”
BackgroundSelf-citationMartinez‐Valdes, E., Negro, F., Laine, C. M., Falla, D., Mayer, F., & Farina, D. (2017) · The Journal of Physiology · doi:10.1113/jp273662 · Cited by 215
“…of the matrix of the measurements (multi-channel EMG signals) and the specific properties of the sources (non-Gaussianity/sparsity), it is possible to separate the activity of individual motor unit spike trains using techniques of linear instantaneous blind source separation (Negro et al. 2016).”
BackgroundMethodInfluentialSelf-citationPrinciples of Motor Unit Physiology Evolve With Advances in Technology
Farina, D., Negro, F., Muceli, S., & Enoka, R. M. (2016) · Physiology · doi:10.1152/physiol.00040.2015 · Cited by 212
Self-citationLi, W., Shi, P., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.621885 · Cited by 211
“Blind source separation is a factorization method different from NMF, which decomposes the recorded sEMG signal into the individual spike trains of motor neurons (Negro et al., 2016; Farina et al., 2017).”
MethodAssociations between motor unit action potential parameters and surface EMG features
Del Vecchio, A., Negro, F., Felici, F., & Farina, D. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00482.2017 · Cited by 176
Self-citationA Modular, Smart, and Wearable System for High Density sEMG Detection
Cerone, G. L., Botter, A., & Gazzoni, M. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2904398 · Cited by 111
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Optimizing NV magnetometry for magnetoneurography and magnetomyography applications
Zhang, C., Zhang, J., Widmann, M., Benke, M., Kübler, M., Dasari, D., Klotz, T., Gizzi, L., Röhrle, O., Brenner, P., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1034391 · Cited by 34
“Accordingly, non-invasive MMG is superior to EMG for distinguishing spatially shifted muscle fiber sources; something highly desirable, for example, for decomposing an interference signal into the spike trains of individual motor units (e.g., Holobar and Zazula, 2007; De Luca et al., 2015; Negro et al., 2016) and for…”
BackgroundMuceli, S., Poppendieck, W., Hoffmann, K.-P., Dosen, S., Benito-León, J., Barroso, F. O., Pons, J. L., & Farina, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab047a · Cited by 33
Self-citationMuceli, S., Bergmeister, K. D., Hoffmann, K.-P., Aman, M., Vukajlija, I., Aszmann, O. C., & Farina, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaed85 · Cited by 30
Self-citation
Metadata
- Authors
- Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-02-29
- Volume
- 13
- Issue
- 2
- Pages
- 026027
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2290981976
- Cited by
- 647
- References
- 45
- FWCI
- 18.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.