OBJECTIVE: Powered exoskeletons promise to increase the quality of life of people with lower-body paralysis or weakened legs by assisting or restoring legged mobility while providing health benefits across multiple physiological systems. Here, a systematic review of the literature on powered exoskeletons addressed critical questions: What is the current evidence of clinical efficacy for lower-limb powered exoskeletons? What are the benefits and risks for individuals with spinal cord injury (SCI)? What are the levels of injury considered in such studies? What are their outcome measures? What are the opportunities for the next generation exoskeletons? APPROACH: A systematic search of online databases was performed to identify clinical trials and safety or efficacy studies with lower-limb powered exoskeletons for individuals with SCI. Twenty-two studies with eight powered exoskeletons thus selected, were analyzed based on the protocol design, subject demographics, study duration, and primary/secondary outcome measures for assessing exoskeleton's performance in SCI subjects. MAIN RESULTS: Findings show that the level of injury varies across studies, with T10 injuries being represented in 45.4% of the studies. A categorical breakdown of outcome measures revealed 63% of these measures were gait and ambulation related, followed by energy expenditure (16%), physiological improvements (13%), and usability and comfort (8%). Moreover, outcome measures varied across studies, and none had measures spanning every category, making comparisons difficult. SIGNIFICANCE: This review of the literature shows that a majority of current studies focus on thoracic level injury as well as there is an emphasis on ambulatory-related primary outcome measures. Future research should: 1) develop criteria for optimal selection and training of patients most likely to benefit from this technology, 2) design multimodal gait intention detection systems that engage and empower the user, 3) develop real-time monitoring and diagnostic capabilities, and 4) adopt comprehensive metrics for assessing safety, benefits, and usability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094 · cited 3×
“For example, none of the studies measured changes in sexual function, which is one of the most desired improvements of the SCI population (Anderson 2004).”
BackgroundInfluentialLower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327 · cited 1×
“For this information, the 2 J. Neural Eng. 13 (2016) 031001 Topical Review reader is directed to several published reviews surveying the state-of-the-art for lower-extremity powered exoskeletons (Ferris et al 2007, Dollar and Herr 2008, Pons 2008, Yang et al 2008, Bogue 2009, Herr 2009).”
BackgroundControl strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047 · cited 2×
“Risks of falling, tripping and slipping not only endanger the safety of patients using the exoskeleton but also have social, emotional, and psychological consequences (Tucker et al 2015).”
BackgroundReducing the energy cost of human walking using an unpowered exoskeleton
Collins, S. H., Wiggin, M. B., & Sawicki, G. S. (2015) · Nature · doi:10.1038/nature14288 · Cited by 967 · cited 1×
“%) relative to not wearing an exoskeleton (Mooney et al 2014); even in the case of passive exoskeletons (Collins et al 2015).”
BackgroundEsquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958
Rehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714 · cited 5×
“Thus, for a simple paradigm shift in future exoskeleton research for the SCI population, studies should broaden their scope, including metrics across multiple 11 physiological systems as well as improvements in areas related to QOL and usability.”
BackgroundInfluentialLocomotor Training After Human Spinal Cord Injury: A Series of Case Studies
Behrman, A. L., & Harkema, S. J. (2000) · Physical Therapy · doi:10.1093/ptj/80.7.688 · Cited by 593
Zeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., & Esquenazi, A. (2012) · The Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000003 · Cited by 537 · cited 5×
“The device senses the patient’s movements to control externally powered gait using closed-loop control algorithms (Zeilig et al 2012).”
BackgroundMethodResultInfluentialWearable Robots: Biomechatronic Exoskeletons
Pons, J. L. (2008) · Cited by 520
Self-citationHAL: Hybrid Assistive Limb Based on Cybernics
Sankai, Y. (2010) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-642-14743-2_3 · Cited by 479
Cited by
Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
EEG-Based BCI Control Schemes for Lower-Limb Assistive-Robots
Tariq, M., Trivailo, P. M., & Simic, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00312 · Cited by 245
“The controller compares current state with the desired state of the device and modulates the power input to the device accordingly (Millán et al., 2009; Duvinage et al., 2012; Noda et al., 2012; Contreras-Vidal and Grossman, 2013; Do et al., 2013; Kilicarslan et al., 2013; Xu et al., 2014; Contreras-Vidal et al., 2016…”
BackgroundBrain–machine interfaces for controlling lower-limb powered robotic systems
He, Y., Eguren, D., Azorín, J. M., Grossman, R. G., Luu, T. P., & Contreras-Vidal, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa8c0 · Cited by 224
Self-citationRobotic Rehabilitation and Spinal Cord Injury: a Narrative Review
Mekki, M., Delgado, A. D., Fry, A., Putrino, D., & Huang, V. (2018) · Neurotherapeutics · doi:10.1007/s13311-018-0642-3 · Cited by 216
Bio-inspired upper limb soft exoskeleton to reduce stroke-induced complications
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L. (2018) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aad8d4 · Cited by 92
An Analysis of Usability Evaluation Practices and Contexts of Use in Wearable Robotics
Meyer, J. T., Gassert, R., & Lambercy, O. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00963-8 · Cited by 58
“comes on comfort, ergonomics, satisfaction, and/or mental demand are drastically 378 scarce compared to performance-related outcomes [22, 38].”
Background
Metadata
- Authors
- Contreras-Vidal, J. L., A Bhagat, N., Brantley, J., Cruz-Garza, J. G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S. H., Zhu, F., & Pons, J. L.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-04-11
- Volume
- 13
- Issue
- 3
- Pages
- 031001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2335038755
- Cited by
- 216
- References
- 76
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.