Powered exoskeletons for bipedal locomotion after spinal cord injury
Open accessThe DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Powered exoskeletons promise to increase the quality of life of people with lower-body paralysis or weakened legs by assisting or restoring legged mobility while providing health benefits across multiple physiological systems. Here, a systematic review of the literature on powered exoskeletons addressed critical questions: What is the current evidence of clinical efficacy for lower-limb powered exoskeletons? What are the benefits and risks for individuals with spinal cord injury (SCI)? What are the levels of injury considered in such studies? What are their outcome measures? What are the opportunities for the next generation exoskeletons? APPROACH: A systematic search of online databases was performed to identify clinical trials and safety or efficacy studies with lower-limb powered exoskeletons for individuals with SCI. Twenty-two studies with eight powered exoskeletons thus selected, were analyzed based on the protocol design, subject demographics, study duration, and primary/secondary outcome measures for assessing exoskeleton's performance in SCI subjects. MAIN RESULTS: Findings show that the level of injury varies across studies, with T10 injuries being represented in 45.4% of the studies. A categorical breakdown of outcome measures revealed 63% of these measures were gait and ambulation related, followed by energy expenditure (16%), physiological improvements (13%), and usability and comfort (8%). Moreover, outcome measures varied across studies, and none had measures spanning every category, making comparisons difficult. SIGNIFICANCE: This review of the literature shows that a majority of current studies focus on thoracic level injury as well as there is an emphasis on ambulatory-related primary outcome measures. Future research should: 1) develop criteria for optimal selection and training of patients most likely to benefit from this technology, 2) design multimodal gait intention detection systems that engage and empower the user, 3) develop real-time monitoring and diagnostic capabilities, and 4) adopt comprehensive metrics for assessing safety, benefits, and usability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094 · cited 3×
“For example, none of the studies measured changes in sexual function, which is one of the most desired improvements of the SCI population (Anderson 2004).”
BackgroundInfluentialLower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327 · cited 1×
“For this information, the 2 J. Neural Eng. 13 (2016) 031001 Topical Review reader is directed to several published reviews surveying the state-of-the-art for lower-extremity powered exoskeletons (Ferris et al 2007, Dollar and Herr 2008, Pons 2008, Yang et al 2008, Bogue 2009, Herr 2009).”
BackgroundControl strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047 · cited 2×
“Risks of falling, tripping and slipping not only endanger the safety of patients using the exoskeleton but also have social, emotional, and psychological consequences (Tucker et al 2015).”
BackgroundReducing the energy cost of human walking using an unpowered exoskeleton
Collins, S. H., Wiggin, M. B., & Sawicki, G. S. (2015) · Nature · doi:10.1038/nature14288 · Cited by 967 · cited 1×
“%) relative to not wearing an exoskeleton (Mooney et al 2014); even in the case of passive exoskeletons (Collins et al 2015).”
BackgroundEsquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958
Rehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N. (2003) · Autonomous Robots · doi:10.1023/a:1024494031121 · Cited by 714 · cited 5×
“Thus, for a simple paradigm shift in future exoskeleton research for the SCI population, studies should broaden their scope, including metrics across multiple 11 physiological systems as well as improvements in areas related to QOL and usability.”
BackgroundInfluentialLocomotor Training After Human Spinal Cord Injury: A Series of Case Studies
Behrman, A. L., & Harkema, S. J. (2000) · Physical Therapy · doi:10.1093/ptj/80.7.688 · Cited by 593
Zeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., & Esquenazi, A. (2012) · The Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000003 · Cited by 537 · cited 5×
“The device senses the patient’s movements to control externally powered gait using closed-loop control algorithms (Zeilig et al 2012).”
BackgroundMethodResultInfluentialWearable Robots: Biomechatronic Exoskeletons
Pons, J. L. (2008) · Cited by 520
Self-citationHAL: Hybrid Assistive Limb Based on Cybernics
Sankai, Y. (2010) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-642-14743-2_3 · Cited by 479
Wirz, M., Zemon, D. H., Rupp, R., Scheel, A., Colombo, G., Dietz, V., & Hornby, T. G. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.08.004 · Cited by 479
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461
Exoskeletons and robotic prosthetics: a review of recent developments
Bogue, R. (2009) · Industrial Robot: An International Journal · doi:10.1108/01439910910980141 · Cited by 348 · cited 1×
“For this information, the 2 J. Neural Eng. 13 (2016) 031001 Topical Review reader is directed to several published reviews surveying the state-of-the-art for lower-extremity powered exoskeletons (Ferris et al 2007, Dollar and Herr 2008, Pons 2008, Yang et al 2008, Bogue 2009, Herr 2009).”
BackgroundWho wants to walk? Preferences for recovery after SCI: a longitudinal and cross-sectional study
Ditunno, P. L., Patrick, M., Stineman, M., & Ditunno, J. F. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102172 · Cited by 332
Jiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
Wagner, J., Solis-Escalante, T., Grieshofer, P., Neuper, C., Müller-Putz, G., & Scherer, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.08.019 · Cited by 301 · cited 1×
“…automated gait intent detection and closed-loop control involving both of these systems (Suzuki et al 2007, Fitzsimmons et al 2009, Wieser et al 2010, Presacco et al 2011, 2012, Wagner et al 2012, Kilicarslan et al 2013, Bulea et al 2014, He et al 2014, Kwak et al 2015), are also being explored.”
MethodA systematic review of functional ambulation outcome measures in spinal cord injury
the SCIRE Research Team, Lam, T., Noonan, V. K., & Eng, J. J. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102134 · Cited by 286 · cited 2×
“Seven primary measures associated with functional ambulation in SCI patients were identified by a recent survey (Lam et al 2011): 10 meter walk test (10 mWT), 6 minute walk test (6 mWT), timed up and go (TUG), spinal-cord injury functional ambulation inventory (SCI-FAI), functional independence…”
BackgroundMethodBlank, A. A., French, J. A., Pehlivan, A. U., & O’Malley, M. K. (2014) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-014-0056-z · Cited by 240
The development and testing of a human machine interface for a mobile medical exoskeleton
Strausser, K. A., & Kazerooni, H. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6095025 · Cited by 226
Boeker, M., Vach, W., & Motschall, E. (2013) · BMC Medical Research Methodology · doi:10.1186/1471-2288-13-131 · Cited by 225 · cited 1×
“Since Google Scholar restricts search terms to 256 characters (Boeker et al 2013), we added the exoskeleton names to the search terms one at a time, i.e. (ORIGINAL_SEARCH_TERMS) AND (EXOSKELETON_NAME).”
BackgroundSpinal Cord Injury Research Evidence (SCIRE) Research Team, Louie, D. R., Eng, J. J., & Lam, T. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0074-9 · Cited by 224
A lower limb exoskeleton control system based on steady state visual evoked potentials
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056009 · Cited by 221 · cited 1×
“…automated gait intent detection and closed-loop control involving both of these systems (Suzuki et al 2007, Fitzsimmons et al 2009, Wieser et al 2010, Presacco et al 2011, 2012, Wagner et al 2012, Kilicarslan et al 2013, Bulea et al 2014, He et al 2014, Kwak et al 2015), are also being explored.”
MethodAach, M., Cruciger, O., Sczesny-Kaiser, M., Höffken, O., Meindl, R. C., Tegenthoff, M., Schwenkreis, P., Sankai, Y., & Schildhauer, T. A. (2014) · The Spine Journal · doi:10.1016/j.spinee.2014.03.042 · Cited by 218
Perceived difficulty in dealing with consequences of spinal cord injury
Widerström-Noga, E. G., Felipe-Cuervo, E., Broton, J. G., Duncan, R. C., & Yezierski, R. P. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90203-4 · Cited by 209 · cited 1×
“…were decreased ability to walk or move, decreased control of bowel, decreased control of bladder, decreased sexual function, and pain (means ranged from 8.2 to 6.2); moreover, high ratings of feeling sad were associated with high ratings of most other consequences (Widerstrom-Noga et al 1999).”
BackgroundInfluentialFarris, R. J., Quintero, H. A., Murray, S. A., Ha, K. H., Hartigan, C., & Goldfarb, M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2268320 · Cited by 208 · cited 3×
“A single session study among the twenty-two studies is also present (Farris et al 2014).”
BackgroundNeural decoding of treadmill walking from noninvasive electroencephalographic signals
Presacco, A., Goodman, R., Forrester, L., & Contreras-Vidal, J. L. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00104.2011 · Cited by 203 · cited 1×
“…automated gait intent detection and closed-loop control involving both of these systems (Suzuki et al 2007, Fitzsimmons et al 2009, Wieser et al 2010, Presacco et al 2011, 2012, Wagner et al 2012, Kilicarslan et al 2013, Bulea et al 2014, He et al 2014, Kwak et al 2015), are also being explored.”
MethodSelf-citationMobility Outcomes Following Five Training Sessions with a Powered Exoskeleton
Hartigan, C., Kandilakis, C., Dalley, S., Clausen, M., Wilson, E., Morrison, S., Etheridge, S., & Farris, R. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2102-93 · Cited by 201 · cited 2×
“This is important as recent studies have reported grade I/II skin aberrations in five out of ten enrolled subjects (Benson et al 2015), and bruising and grade-1 skin redness in two patients during exoskeleton use (Hartigan et al 2015).”
BackgroundHigh accuracy decoding of user intentions using EEG to control a lower-body exoskeleton
Kilicarslan, A., Prasad, S., Grossman, R. G., & Contreras-Vidal, J. L. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610821 · Cited by 196
Self-citationMehrholz, J., & Pohl, M. (2012) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0943 · Cited by 193
Kozlowski, A., Bryce, T., & Dijkers, M. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2102-110 · Cited by 193 · cited 3×
“For example, in (Kozlowski et al 2015), the authors quantified the training period in terms of number of sessions required to use the exoskeleton to stand up, walk for at least 30 min, and sit down with little or no assistance.”
BackgroundInfluentialKolakowsky-Hayner, S. A. (2013) · Journal of Spine · doi:10.4172/2165-7939.s4-003 · Cited by 190 · cited 1×
“The time since injury reveals, that most of the studies recruited chronic ( 6 months) SCI subjects with the exception of (Kolakowsky-Hayner et al 2013, Kozlowski et al 2015) which also recruited acute SCI subjects.”
BackgroundSpinal Cord Injury in the Pediatric Population: A Systematic Review of the Literature
Parent, S., Mac-Thiong, J.-M., Roy-Beaudry, M., Sosa, J. F., & Labelle, H. (2011) · Journal of Neurotrauma · doi:10.1089/neu.2009.1153 · Cited by 188 · cited 2×
“Decreased mobility is likely related to higher blood pressure, shorter life expectancy, social stigma and increased rates of depression (Parent et al 2011).”
BackgroundA Review of exoskeleton-type systems and their key technologies
Yang, C.-J., Zhang, J.-F., Chen, Y., Dong, Y.-M., & Zhang, Y. (2008) · Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science · doi:10.1243/09544062jmes936 · Cited by 187 · cited 1×
“For this information, the 2 J. Neural Eng. 13 (2016) 031001 Topical Review reader is directed to several published reviews surveying the state-of-the-art for lower-extremity powered exoskeletons (Ferris et al 2007, Dollar and Herr 2008, Pons 2008, Yang et al 2008, Bogue 2009, Herr 2009).”
BackgroundExtracting kinematic parameters for monkey bipedal walking from cortical neuronal ensemble activity
Fitzsimmons, N. A. (2009) · Frontiers in Integrative Neuroscience · doi:10.3389/neuro.07.003.2009 · Cited by 186
A PHYSIOLOGIST'S PERSPECTIVE ON ROBOTIC EXOSKELETONS FOR HUMAN LOCOMOTION
FERRIS, D. P., SAWICKI, G. S., & DALEY, M. A. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001138 · Cited by 185 · cited 1×
“For this information, the 2 J. Neural Eng. 13 (2016) 031001 Topical Review reader is directed to several published reviews surveying the state-of-the-art for lower-extremity powered exoskeletons (Ferris et al 2007, Dollar and Herr 2008, Pons 2008, Yang et al 2008, Bogue 2009, Herr 2009).”
BackgroundTsukahara, A., Hasegawa, Y., Eguchi, K., & Sankai, Y. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2364618 · Cited by 174
Benson, I., Hart, K., Tussler, D., & van Middendorp, J. J. (2016) · Clinical Rehabilitation · doi:10.1177/0269215515575166 · Cited by 174
Lajeunesse, V., Vincent, C., Routhier, F., Careau, E., & Michaud, F. (2016) · Disability and Rehabilitation: Assistive Technology · doi:10.3109/17483107.2015.1080766 · Cited by 170
Kubota, S., Nakata, Y., Eguchi, K., Kawamoto, H., Kamibayashi, K., Sakane, M., Sankai, Y., & Ochiai, N. (2013) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.12.020 · Cited by 165
Stauffer, Y., Allemand, Y., Bouri, M., Fournier, J., Clavel, R., Metrailler, P., Brodard, R., & Reynard, F. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008288 · Cited by 163 · cited 2×
“…years 10 mWT 6 minWT TUG 19 (Yang et al 2015) [NCT02118194] ReWalk 12–120 1–2.0 1 12 12 24–64 T4,T10,T4, C8/T8,T11, T5,T1,T9,T7, T2,T2,C8 1–16 X X — 20 (Stauffer et al 2009) WalkTrainer 12 1 1 12 6 — — — — — — 21 (Tanabe et al 2013a) WPAL 2–11 1 — — 7 32–61 T12,T12,T11, T9,T6,T6,T6 6–20 X — — 22…”
BackgroundInfluentialThe physiological basis of neurorehabilitation - locomotor training after spinal cord injury
Hubli, M., & Dietz, V. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-5 · Cited by 159 · cited 1×
“Even in the case of complete SCI subjects with no voluntary control below the level of the lesion, manually-assisted or robot assisted locomotor training can result in beneficial effects in cardiovascular and musculoskeletal systems (Hesse 2001, Hubli and Dietz 2013).”
BackgroundHeart rate and oxygen demand of powered exoskeleton-assisted walking in persons with paraplegia
Asselin, P. K., Knezevic, S., Kornfeld, S. D., Cirnigliaro, C. M., Agranova-Breyter, I., Bauman, W. A., & Spungen, A. M. (2015) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.02.0060 · Cited by 152
Fineberg, D. B., Asselin, P. K., Harel, N. Y., Agranova-Breyter, I., Kornfeld, S. D., Bauman, W. A., & Spungen, A. M. (2013) · Journal of Spinal Cord Medicine · doi:10.1179/2045772313y.0000000126 · Cited by 145 · cited 1×
“Training duration varied from single trial evaluations (Farris et al 2014) to longitudinal studies with many subjects training over many sessions for more than two 9 J. Neural Eng. 13 (2016) 031001 Topical Review months (e.g. Esquenazi et al 2012, Fineberg et al 2013, Yang et al 2015).”
BackgroundFederici, S., Meloni, F., Bracalenti, M., & Filippis, M. L. D. (2015) · Neurorehabilitation · doi:10.3233/nre-151265 · Cited by 143 · cited 1×
“…of different types of exoskeletons from an engineering perspective (JimenezFabian and Verlinden 2012, Tucker et al 2015), including gait speed (Louie et al 2015), few have analyzed the rehabilitation efficacy with these devices (Mehrholz and Pohl 2012, Federici et al 2015, Lajeunesse et al 2015).”
BackgroundSitting and standing intention can be decoded from scalp EEG recorded prior to movement execution
Bulea, T. C., Prasad, S., Kilicarslan, A., & Contreras-Vidal, J. L. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00376 · Cited by 140 · cited 1×
“…automated gait intent detection and closed-loop control involving both of these systems (Suzuki et al 2007, Fitzsimmons et al 2009, Wieser et al 2010, Presacco et al 2011, 2012, Wagner et al 2012, Kilicarslan et al 2013, Bulea et al 2014, He et al 2014, Kwak et al 2015), are also being explored.”
MethodSelf-citationEvans, N. H., Hartigan, C., Kandilakis, C., Pharo, E., & Clesson, I. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2102-122 · Cited by 138
Kressler, J., Thomas, C. K., Field-Fote, E. C., Sanchez, J. C., Widerström-Noga, E. G., Cilien, D. C., Gant, K. L., Ginnety, K., González, H. F. J., Martínez, A., et al. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.04.026 · Cited by 130
Yang, A. H., Asselin, P. K., Knezevic, S., Kornfeld, S. D., & Spungen, A. M. (2015) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci2102-100 · Cited by 125 · cited 4×
“…Number of sessions Duration in hours Frequency per week Duration in weeks Number Age Injury level Time since injury in years 10 mWT 6 minWT TUG 19 (Yang et al 2015) [NCT02118194] ReWalk 12–120 1–2.0 1 12 12 24–64 T4,T10,T4, C8/T8,T11, T5,T1,T9,T7, T2,T2,C8 1–16 X X — 20 (Stauffer et al 2009)…”
BackgroundMethodInfluentialUpdate on distance and velocity requirements for community ambulation.
Andrews, A. W., Chinworth, S. A., Bourassa, M., Garvin, M., Benton, D., & Tanner, S. (2010) · PubMed · Cited by 124
Fleerkotte, B. M., Koopman, B., Buurke, J. H., van Asseldonk, E. H. F., van der Kooij, H., & Rietman, J. S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-26 · Cited by 121 · cited 1×
“The effectiveness of impedance control has been demonstrated, but no comparison has yet been done to show any statistically significant advantage over other methods (Fleerkotte et al 2014).”
Presacco, A., Forrester, L. W., & Contreras-Vidal, J. L. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2188304 · Cited by 115 · cited 1×
“…automated gait intent detection and closed-loop control involving both of these systems (Suzuki et al 2007, Fitzsimmons et al 2009, Wieser et al 2010, Presacco et al 2011, 2012, Wagner et al 2012, Kilicarslan et al 2013, Bulea et al 2014, He et al 2014, Kwak et al 2015), are also being explored.”
MethodSelf-citationHammell, K. R. W. (2010) · Disability and Rehabilitation · doi:10.3109/09638280903420325 · Cited by 110 · cited 2×
“A previous review of the outcomes of SCI research found similar pitfalls widely present across all areas of SCI research (Hammell 2010).”
BackgroundCruciger, O., Schildhauer, T. A., Meindl, R. C., Tegenthoff, M., Schwenkreis, P., Çıtak, M., & Aach, M. (2014) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2014.981875 · Cited by 103
Temporal and spatial patterns of cortical activation during assisted lower limb movement
Wieser, M., Haefeli, J., Buetler, L., Jäncke, L., Riener, R., & Koeneke, S. (2010) · Experimental Brain Research · doi:10.1007/s00221-010-2223-5 · Cited by 102 · cited 1×
“…interfaces for automated gait intent detection and closed-loop control involving both of these systems (Suzuki et al 2007, Fitzsimmons et al 2009, Wieser et al 2010, Presacco et al 2011, 2012, Wagner et al 2012, Kilicarslan et al 2013, Bulea et al 2014, He et al 2014, Kwak et al 2015), are also…”
MethodA Powered Lower Limb Orthosis for Providing Legged Mobility in Paraplegic Individuals
Quintero, H., Farris, R. J., Hartigan, C., Clesson, I., & Goldfarb, M. T. (2011) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci1701-25 · Cited by 93 · cited 1×
“As a safety measure there are brakes at the knee joints to prevent knee buckling in case of power failure (Quintero et al 2011).”
BackgroundYang, J. F., & Musselman, K. E. (2012) · Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000036 · Cited by 91
Real-Time Strap Pressure Sensor System for Powered Exoskeletons
Tamez-Duque, J., Cobian-Ugalde, R., Kilicarslan, A., Venkatakrishnan, A., Soto, R., & Contreras-Vidal, J. L. (2015) · Sensors · doi:10.3390/s150204550 · Cited by 83
Self-citationApplications of Brain–Machine Interface Systems in Stroke Recovery and Rehabilitation
Venkatakrishnan, A., Francisco, G. E., & Contreras-Vidal, J. L. (2014) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-014-0051-4 · Cited by 78 · cited 1×
“It is generally agreed that locomotor training using robotassisted therapies depends on patient engagement (Venkatakrishnan et al 2014), reward (Goodman et al 2014) and the desire of the patient to conquer the disability.”
BackgroundSelf-citationThe effects of spinal cord injury and exercise on bone mass: A literature review
Dolbow, D. R., Gorgey, A. S., Daniels, J. A., Adler, R. A., Moore, J. R., & Gater, D. R. (2011) · Neurorehabilitation · doi:10.3233/nre-2011-0702 · Cited by 77 · cited 3×
“Decreased BMD is a common symptom in SCI patients (Dolbow et al 2011) and degradation becomes rapidly evident within the first year of sustaining the injury (Coupaud et al 2015).”
BackgroundLocomotor therapy in neurorehabilitation
Hesse, S. (2001) · NeuroRehabilitation · doi:10.3233/nre-2001-16302 · Cited by 76 · cited 3×
“Even in the case of complete SCI subjects with no voluntary control below the level of the lesion, manually-assisted or robot assisted locomotor training can result in beneficial effects in cardiovascular and musculoskeletal systems (Hesse 2001, Hubli and Dietz 2013).”
BackgroundMethodLocomotor training using a robotic device in patients with subacute spinal cord injury
Schwartz, I., Sajina, A., Neeb, M., Fisher, I., Leurer, M. K., & Meiner, Z. (2011) · Spinal Cord · doi:10.1038/sc.2011.59 · Cited by 73
He, Y., Nathan, K., Venkatakrishnan, A., Rovekamp, R., Beck, C., Ozdemir, R. A., Francisco, G. E., & Contreras-Vidal, J. L. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944497 · Cited by 67 · cited 1×
“…automated gait intent detection and closed-loop control involving both of these systems (Suzuki et al 2007, Fitzsimmons et al 2009, Wieser et al 2010, Presacco et al 2011, 2012, Wagner et al 2012, Kilicarslan et al 2013, Bulea et al 2014, He et al 2014, Kwak et al 2015), are also being explored.”
MethodSelf-citationIncreased reward in ankle robotics training enhances motor control and cortical efficiency in stroke
Goodman, R. N., Rietschel, J. C., Roy, A., Jung, B. C., Diaz, J., Macko, R. F., & Forrester, L. W. (2014) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2013.02.0050 · Cited by 65 · cited 1×
“It is generally agreed that locomotor training using robotassisted therapies depends on patient engagement (Venkatakrishnan et al 2014), reward (Goodman et al 2014) and the desire of the patient to conquer the disability.”
BackgroundWearable Power-Assist Locomotor (WPAL) for supporting upright walking in persons with paraplegia
Tanabe, S., Hirano, S., & Saitoh, E. (2013) · Neurorehabilitation · doi:10.3233/nre-130932 · Cited by 61
Role of Robotics in Neurorehabilitation
Hidler, J. M., & Sainburg, R. L. (2011) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci1701-42 · Cited by 58 · cited 2×
“reproducible gait patterns as well as close monitoring of patient progress during therapy (Hidler and Sainburg 2011).”
BackgroundCoupaud, S., McLean, A., Purcell, M., Fraser, M. H., & Allan, D. (2015) · Bone · doi:10.1016/j.bone.2015.01.005 · Cited by 55 · cited 1×
“Decreased BMD is a common symptom in SCI patients (Dolbow et al 2011) and degradation becomes rapidly evident within the first year of sustaining the injury (Coupaud et al 2015).”
BackgroundDesign of the Wearable Power-Assist Locomotor (WPAL) for paraplegic gait reconstruction
Tanabe, S., Saitoh, E., Hirano, S., Katoh, M., Takemitsu, T., Uno, A., Shimizu, Y., Muraoka, Y., & Suzuki, T. (2012) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2012.688238 · Cited by 51 · cited 5×
“Experimental protocol Subjects Outcome variables ID Reference Device Number of sessions Duration in hours Frequency per week Duration in weeks Number Age Injury level Time since injury in years 10 mWT 6 minWT TUG 19 (Yang et al 2015) [NCT02118194] ReWalk 12–120 1–2.0 1 12 12 24–64 T4,T10,T4, C8/T8,T11, T5,T1,T9,T7, T2…”
BackgroundInfluentialdel‐Ama, A. J., Gil-Agudo, A. M., Pons, J. L., & Moreno, J. C. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00298 · Cited by 50 · cited 2×
“…the robotic joints; software limits for maximum and minimum positions in the admittance controller for the knee joint, maximum output torques, and FES pulse width and amplitude modulation; and a mechanical safety button to physically disconnect power from the entire hardware (del-Ama et al 2014).”
BackgroundMethodSelf-citationCooperative walk control of paraplegia patient and assistive system
Hasegawa, Y., Jang, J., & Sankai, Y. (2009) · 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2009.5354192 · Cited by 43 · cited 1×
“Other gait intent detection systems based on eye gaze (Duvinage et al 2011) and hand movements (Hasegawa et al 2009), have also been developed.”
BackgroundFramework for Assessment of the Usability of Lower-Extremity Robotic Exoskeletal Orthoses
Bryce, T. N., Dijkers, M. P. J. M., & Kozlowski, A. J. (2015) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000000321 · Cited by 40 · cited 2×
“Stressing the bone through muscle contractions, such as natural muscle contractions induced through walking or artificial contractions by FES, shows potential for increasing BMD in non-weight bearing individuals (Dolbow et al 2011, Bryce et al 2015).”
Backgrounddel‐Ama, A. J., Gil-Agudo, A. M., Bravo-Esteban, E., Pérez‐Nombela, S., Pons, J. L., & Moreno, J. C. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.10.014 · Cited by 39 · cited 1×
“The Kinesis hybrid controller works to minimize the interaction forces between the user’s body and the exoskeleton (del-Ama et al 2014, 2015).”
MethodSelf-citationOnline Assessment of Human-Robot Interaction for Hybrid Control of Walking
del‐Ama, A. J., Moreno, J. C., Gil-Agudo, A. M., Reyes-Guzmán, A. D. L., & Pons, J. L. (2011) · Sensors · doi:10.3390/s120100215 · Cited by 37
Self-citationHuman‐Centered Design of Wearable Neuroprostheses and Exoskeletons
Contreras-Vidal, J. L., Kilicarslan, A., Huang, H., & Grossman, R. G. (2015) · AI Magazine · doi:10.1609/aimag.v36i4.2613 · Cited by 29 · cited 1×
“To gain adoption by end users, exoskeletons should be effective, reliable, safe and engaging and support the user in performing intended actions with minimal effort and errors with adequate interaction time (Contreras-Vidal et al 2015).”
BackgroundSelf-citationControl of a lower limb active prosthesis with eye movement sequences
Duvinage, M., Castermans, T., & Dutoit, T. (2011) · IEEE Symposium on Computational Intelligence, Cognitive Algorithms, Mind, and Brain (CCMB) · doi:10.1109/ccmb.2011.5952116 · Cited by 27
Robot-Aided Gait Training in an Individual With Chronic Spinal Cord Injury: A Case Study
Bishop, L., Stein, J. M., & Wong, C. K. (2012) · Neurology Report · doi:10.1097/npt.0b013e3182624c87 · Cited by 18 · cited 2×
“…CA, USA, http://alterg. com/products/bionic-leg/professional-physical-therapy/) The AlterG Bionic Leg (formerly Tibion Bionic Leg) is a unilateral robotic knee orthoses (RKO) for individuals with asymmetric lower-limb motor impairments, for example the Brown-Sequared syndrome (Bishop et al 2012).”
Background
Cited by
Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
EEG-Based BCI Control Schemes for Lower-Limb Assistive-Robots
Tariq, M., Trivailo, P. M., & Simic, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00312 · Cited by 245
“The controller compares current state with the desired state of the device and modulates the power input to the device accordingly (Millán et al., 2009; Duvinage et al., 2012; Noda et al., 2012; Contreras-Vidal and Grossman, 2013; Do et al., 2013; Kilicarslan et al., 2013; Xu et al., 2014; Contreras-Vidal et al., 2016…”
BackgroundBrain–machine interfaces for controlling lower-limb powered robotic systems
He, Y., Eguren, D., Azorín, J. M., Grossman, R. G., Luu, T. P., & Contreras-Vidal, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa8c0 · Cited by 224
Self-citationRobotic Rehabilitation and Spinal Cord Injury: a Narrative Review
Mekki, M., Delgado, A. D., Fry, A., Putrino, D., & Huang, V. (2018) · Neurotherapeutics · doi:10.1007/s13311-018-0642-3 · Cited by 216
Bio-inspired upper limb soft exoskeleton to reduce stroke-induced complications
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L. (2018) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aad8d4 · Cited by 92
Metadata
- Authors
- Contreras-Vidal, J. L., A Bhagat, N., Brantley, J., Cruz-Garza, J. G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S. H., Zhu, F., & Pons, J. L.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-04-11
- Volume
- 13
- Issue
- 3
- Pages
- 031001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2335038755
- Cited by
- 216
- References
- 76
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.