Electrotactile EMG feedback improves the control of prosthesis grasping force
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: A drawback of active prostheses is that they detach the subject from the produced forces, thereby preventing direct mechanical feedback. This can be compensated by providing somatosensory feedback to the user through mechanical or electrical stimulation, which in turn may improve the utility, sense of embodiment, and thereby increase the acceptance rate. APPROACH: In this study, we compared a novel approach to closing the loop, namely EMG feedback (emgFB), to classic force feedback (forceFB), using electrotactile interface in a realistic task setup. Eleven intact-bodied subjects and one transradial amputee performed a routine grasping task while receiving emgFB or forceFB. The two feedback types were delivered through the same electrotactile interface, using a mixed spatial/frequency coding to transmit 8 discrete levels of the feedback variable. In emgFB, the stimulation transmitted the amplitude of the processed myoelectric signal generated by the subject (prosthesis input), and in forceFB the generated grasping force (prosthesis output). The task comprised 150 trials of routine grasping at six forces, randomly presented in blocks of five trials (same force). Interquartile range and changes in the absolute error (AE) distribution (magnitude and dispersion) with respect to the target level were used to assess precision and overall performance, respectively. MAIN RESULTS: Relative to forceFB, emgFB significantly improved the precision of myoelectric commands (min/max of the significant levels) for 23%/36% as well as the precision of force control for 12%/32%, in intact-bodied subjects. Also, the magnitude and dispersion of the AE distribution were reduced. The results were similar in the amputee, showing considerable improvements. SIGNIFICANCE: Using emgFB, the subjects therefore decreased the uncertainty of the forward pathway. Since there is a correspondence between the EMG and force, where the former anticipates the latter, the emgFB allowed for predictive control, as the subjects used the feedback to adjust the desired force even before the prosthesis contacted the object. In conclusion, the online emgFB was superior to the classic forceFB in realistic conditions that included electrotactile stimulation, limited feedback resolution (8 levels), cognitive processing delay, and time constraints (fast grasping).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
MANUAL MOTOR PERFORMANCE IN A DEAFFERENTED MAN
ROTHWELL, J. C., TRAUB, M. M., DAY, B. L., OBESO, J. A., THOMAS, P. K., & MARSDEN, C. D. (1982) · Brain · doi:10.1093/brain/105.3.515 · Cited by 862
Sensory substitution and the human-machine interface
Bach-y-Rita, P., & W. Kercel, S. (2003) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2003.10.013 · Cited by 858
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Restoring the sense of touch with a prosthetic hand through a brain interface
Tabot, G. A., Dammann, J. F., Berg, J. A., Tenore, F. V., Boback, J. L., Vogelstein, R. J., & Bensmaia, S. J. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221113110 · Cited by 320
Research works printed but not linked: 16
- Antfolk, 2013, Sensory feedback in upper limb prosthetics, Expert Rev. Med. Devices, 10, 45, 10.1586/erd.12.68 · DOI · Paper page
- Callier, 2015, Kinematics of unconstrained tactile texture exploration, J. Neurophysiol., 10.1152/jn.00703.2014 · DOI
- Dietrich, 2012, Sensory feedback prosthesis reduces phantom limb pain: proof of a principle, Neurosci. Lett., 507, 97, 10.1016/j.neulet.2011.10.068 · DOI · Paper page
- Dosen, 2015, Sensory feedback in prosthetics: a standardized test bench for closed-loop control, IEEE Trans. Neural Syst. Rehabil. Eng., 23, 267, 10.1109/TNSRE.2014.2371238 · DOI
- Dosen, 2015a, EMG biofeedback for online predictive control of grasping force in a myoelectric prosthesis, J. Neuroeng. Rehabil., 12, 1, 10.1186/s12984-015-0047-z · DOI
- Dosen, 2015b, Building an internal model of a myoelectric prosthesis via closed-loop control for consistent and routine grasping, Exp. Brain Res., 233, 1855, 10.1007/s00221-015-4257-1 · DOI
- Farina, 2014, Bionic limbs: clinical reality and academic promises, Sci. Transl. Med., 6, 257, 10.1126/scitranslmed.3010453 · DOI · Paper page
- Hermsdörfer, 2008, Preserved and impaired aspects of feed-forward grip force control after chronic somatosensory deafferentation, Neurorehabil. Neural Repair, 22, 374, 10.1177/1545968307311103 · DOI
- Johansson, 1992, Sensory-motor coordination during grasping and manipulative actions, Curr. Opin. Neurobiol., 2, 815, 10.1016/0959-4388(92)90139-C · DOI · Paper page
- Johnson, 2014, Does EMG control lead to distinct motor adaptation?, Front. Neurosci., 8, 302, 10.3389/fnins.2014.00302 · DOI
- Kaczmarek, 1991, Electrotactile and vibrotactile displays for sensory substitution systems, Biomed. Eng. IEEE Trans., 38, 1, 10.1109/10.68204 · DOI · Paper page
- Ninu, 2014, Closed loop control of grasping with a myoelectric hand prosthesis: which are the relevant feedback variables for force control?, IEEE Trans. Neural Syst. Rehabil. Eng., 22, 1041, 10.1109/TNSRE.2014.2318431 · DOI
- Parker, 2006, Myoelectric signal processing for control of powered limb prostheses, J. Electromyogr. Kinesiol., 16, 541, 10.1016/j.jelekin.2006.08.006 · DOI · Paper page
- Peerdeman, 2011, Myoelectric forearm prostheses: state of the art from a user-centered perspective, J. Rehabil. Res. Dev., 48, 719, 10.1682/JRRD.2010.08.0161 · DOI · Paper page
- Szeto, 1982, Electrocutaneous stimulation for sensory communication in rehabilitation engineering, IEEE Trans. Biomed. Eng., 29, 300, 10.1109/TBME.1982.324948 · DOI · Paper page
- Witteveen, 2012, Grasping force and slip feedback through vibrotactile stimulation to be used in myoelectric forearm prostheses, 10.1109/EMBC.2012.6346587 · DOI
Cited by
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationA Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“Despite their advantages, only approximately half of the electrotactile feedback systems examined use them [60], [64], [66], [68]–[71], which may impact upon their performance.”
BackgroundMethodA review of invasive and non-invasive sensory feedback in upper limb prostheses
Svensson, P., Wijk, U., Björkman, A., & Antfolk, C. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1332989 · Cited by 192
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“The users of this modality have been able to regulate the grasping forces as well as to the angular displacement of the prosthetic hand to predefined levels (Clemente et al., 2016; Schweisfurth et al., 2016).”
Metadata
- Authors
- Schweisfurth, M. A., Markovic, M., Dosen, S., Teich, F., Graimann, B., & Farina, D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2016-08-22
- Volume
- 13
- Issue
- 5
- Pages
- 056010
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2512336634
- Cited by
- 110
- References
- 6
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Funders
- European Commission under the MYOSENS project (FP7-PEOPLE-2011-IAPP-286208)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrotactile EMG feedback improves the control of prosthesis grasping force. https://app.cochat.ai/papers/10.1088/1741-2560/13/5/056010
- The paper
- Schweisfurth, M. A., Markovic, M., Dosen, S., Teich, F., Graimann, B., & Farina, D. (2016). Electrotactile EMG feedback improves the control of prosthesis grasping force. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/13/5/056010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.