The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Restoring Natural Sensory Feedback in Real-Time Bidirectional Hand Prostheses
Open accessAbstract
A multigrasp, bidirectional hand prosthesis delivers dynamic sensory feedback, allowing a user with a hand amputation to achieve fine grasping force control and realistic object sensing.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Instead, electrical stimulation has shown promise in providing tactile feedback through stimulation of afferent sensory axons (3, 5–7).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [6]
In the citing paper
“Paresthesia was associated with 30 to 50% of the stimulating channels.”
From A neural interface provides long-term stable natural touch perception (2014) · cites this paper as [12]
In the citing paper
“However, the restored sensation allowed a subject to correctly identify three different objects, illustrating the value of sensory feedback on functional control (12).”
From A neural interface provides long-term stable natural touch perception (2014) · cites this paper as [12]
In the citing paper
“TIME electrodes have already been used in sensory stimulation of the ulnar and median nerve as feedback for the control of a prosthetic hand (Raspopovic et al., 2014).”
From Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics (2018) · cites this paper as Raspopovic et al., 2014
In the citing paper
“In another real-time experiment performed with a dexterous prosthetic hand, the TIME electrodes were implanted in the median and ulnar nerves of an amputee. Touch sensation was restored to near-natural, thereby providing precise closed-loop control of the prosthesis [101].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [101]
7 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Hand movements: A window into haptic object recognition
Lederman, S. J., & Klatzky, R. L. (1987) · Cognitive Psychology · doi:10.1016/0010-0285(87)90008-9 · Cited by 2,016
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“In parallel, the rapid development of neural interfaces for the peripheral nervous system (16) has provided potential for new tools through which bidirectional communication with nerves in the stump could be potentially restored.”
BackgroundSelf-citationControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Self-citationControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Self-citationConsumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519 · cited 2×
“The possibility of adding physiologically appropriate touch sensations to hand prosthesis could enhance the controllability and, thus, acceptability (6, 7) of such a device, bringing it closer to the natural manipulation strategy.”
BackgroundTactual discrimination of softness
Srinivasan, M. A., & LaMotte, R. H. (1995) · Journal of Neurophysiology · doi:10.1152/jn.1995.73.1.88 · Cited by 509
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508 · cited 2×
“The possibility of adding physiologically appropriate touch sensations to hand prosthesis could enhance the controllability and, thus, acceptability (6, 7) of such a device, bringing it closer to the natural manipulation strategy.”
Background
Research works printed but not linked: 1
- Johannes M. S., Bigelow J. D., Burck J. M, Harshbarger S. D., Kozlowski M. V., Van Doren T., An overview of the developmental process for the modular prosthetic limb. Johns Hopkins APL Tech. Dig. 30, 207–216 (2011).
Cited by
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Besides non-invasive feedback systems, it is also possible to directly deliver electrotactile stimuli to peripheral nerves via implanted electrodes [83,84].”
Electromyography data for non-invasive naturally-controlled robotic hand prostheses
Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2014) · Scientific Data · doi:10.1038/sdata.2014.53 · Cited by 969
Optoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982
Metadata
- Authors
- Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., Granata, G., Oddo, C. M., Citi, L., Ciancio, A. L., Cipriani, C., Carrozza, M. C., Jensen, W., Guglielmelli, E., Stieglitz, T., Rossini, P. M., & Micera, S.
- Affiliations
- The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa 56025, Italy.
- Scuola Superiore Sant'Anna (IT)
- Università Campus Bio-Medico (IT)
- École Polytechnique Fédérale de Lausanne (CH)
- Laboratory of Biomedical Robotics and Biomicrosystems, Campus Bio-Medico University, Rome 00128, Italy.
- University of Freiburg (DE)
- Department of Geriatrics, Neurosciences and Orthopedics, Catholic University of the Sacred Heart, Rome 00168, Italy.
- IRCCS San Raffaele Roma (IT)
- University of Essex (GB)
- Aalborg University (DK)
- Università Cattolica del Sacro Cuore (IT)
- Corresponding author
- Capogrosso, Marco
- Petrini, Francesco Maria
- Bonizzato, Marco
- Rossini, Paolo Maria
- Micera, Silvestro
- ORCID
- Venue
- Science Translational Medicine
- Published
- 2014-02-05
- Volume
- 6
- Issue
- 222
- Pages
- 222ra19-222ra19
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2134500330
- Semantic Scholar
- 2bd3decb77fb15bd0a7c5644fa5251552a0ac420
- Cited by
- 1,001
- References
- 30
- Citations by year
- 2026: 39 · 2025: 63 · 2024: 72 · 2023: 74 · 2022: 82 · 2021: 93 · 2020: 92 · 2019: 107 · 2018: 111 · 2017: 74 · 2016: 79 · 2015: 85 · 2014: 29
- FWCI
- 40.70
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- SDL (submittedVersion)
- PolyPublie (École Polytechnique de Montréal) (submittedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Open Access at Essex (University of Essex) (submittedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- prosthetic hand, sensory feedback, median nerve stimulation, ulnar nerve stimulation, intrafascicular electrodes, amputees, grip force control, object shape perception, real-time neural decoding, upper limb amputation
- MeSH terms
- Adult, Artificial Limbs, Computer Systems, Electric Stimulation, Hand, Humans, Male, Peripheral Nerves, Hand Strength, Feedback, Sensory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Restoring Natural Sensory Feedback in Real-Time Bidirectional Hand Prostheses. https://app.cochat.ai/papers/10.1126/scitranslmed.3006820
- The paper
- Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., Granata, G., Oddo, C. M., Citi, L., Ciancio, A. L., Cipriani, C., Carrozza, M. C., Jensen, W., Guglielmelli, E., Stieglitz, T., . . . Micera, S. (2014). Restoring Natural Sensory Feedback in Real-Time Bidirectional Hand Prostheses. Science Translational Medicine. https://doi.org/10.1126/scitranslmed.3006820
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.