The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Responses of rabbit retinal ganglion cells to electrical stimulation with an epiretinal electrode
Open accessAbstract
Rational selection of electrical stimulus parameters for an electronic retinal prosthesis requires knowledge of the electrophysiological responses of retinal neurons to electrical stimuli. In this study, we examined the effects of cathodal and anodal current pulses on the extracellularly recorded responses of OFF and ON rabbit retinal ganglion cells (RGCs) in an in vitro preparation. Current pulses (1 msec duration), delivered by a 125 microm electrode placed on the inner retinal surface within the receptive field of a RGC, produced both short-latency (< or =5 msec) and long-latency (8-60 msec) responses. The long-latency responses, but not the short-latency responses, were abolished upon application of the glutamate receptor antagonists CNQX and NBQX, thus indicating that the long-latency responses of RGCs are due to activation of presynaptic neurons in the retina. The latency of the long-latency response depended upon the polarity of the stimulus. For OFF RGCs, the average latency was 11 msec for a cathodal stimulus and 24 msec for an anodal stimulus. For ON RGCs, the average latency was 25 msec for a cathodal stimulus and 16 msec for an anodal stimulus. The threshold current also depended upon the polarity of the stimulus, at least for OFF RGCs. The average threshold current for evoking a long-latency response in OFF RGCs was 10 microA for a cathodal stimulus and 21 microA for an anodal stimulus. In ON RGCs, the average threshold current was 13 microA for a cathodal stimulus and 15 microA for an anodal stimulus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Self-citation
Cited by
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 337
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“Ganglion cells respond to indirect stimulation by firing in bursts after a significant latency (~10 s of milliseconds), likely reflecting neural processing by the presynaptic bipolar cells and other interneurons such as amacrine cells (Jensen et al., 2005).”
Predicting visual sensitivity in retinal prosthesis patients
Horsager, A., Greenwald, S. H., Weiland, J. D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., Boynton, G. M., & Fine, I. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2595 · Cited by 107
“42 ms—a value very similar to electrophysiology estimates of the integration of current by ganglion cells in rodent and primate models.(26,38,49) It should be noted that intracellular current injection results in slower time constants, ranging from 3.”
Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
Temporal interactions during paired-electrode stimulation in two retinal prosthesis subjects
Horsager, A., Boynton, G. M., Greenberg, R. J., & Fine, I. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5282 · Cited by 48
Metadata
- Authors
- Jensen, R. J., Ziv, O. R., & Rizzo, J. F.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2005-02-23
- Volume
- 2
- Issue
- 1
- Pages
- S16-S21
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2048253188
- Cited by
- 110
- References
- 2
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Responses of rabbit retinal ganglion cells to electrical stimulation with an epiretinal electrode. https://app.cochat.ai/papers/10.1088/1741-2560/2/1/003
- The paper
- Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005). Responses of rabbit retinal ganglion cells to electrical stimulation with an epiretinal electrode. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/2/1/003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.