CoChat

Tunable retina encoders for retina implants: why and how

Open access
Eckmiller, Rolf, Neumann, Dirk, Baruth, Oliver · 2005 · Journal of Neural Engineering
Cited by 86

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Current research towards retina implants for partial restoration of vision in blind humans with retinal degenerative dysfunctions focuses on implant and stimulation experiments and technologies. In contrast, our approach takes the availability of an epiretinal multi-electrode neural interface for granted and studies the conditions for successful joint information processing of both retinal prosthesis and brain. Our proposed learning retina encoder (RE) includes information processing modules to simulate the complex mapping operation of parts of the 5-layered neural retina and to provide an iterative, perception-based dialog between RE and human subject. Alternative information processing technologies in the learning RE are being described, which allow an individual optimization of the RE mapping operation by means of iterative tuning with learning algorithms in a dialog between implant wearing subject and RE. The primate visual system is modeled by a retina module (RM) composed of spatio-temporal (ST) filters and a central visual system module (VM). RM performs a mapping 1 of an optical pattern P1 in the physical domain onto a retinal output vector R1(t) in a neural domain, whereas VM performs a mapping 2 of R1(t) in a neural domain onto a visual percept P2 in the perceptual domain. Retinal ganglion cell properties represent non-invertible ST filters in RE, which generate ambiguous output signals. VM generates visual percepts only if the corresponding R1(t) is properly encoded, contains sufficient information, and can be disambiguated. Based on the learning RE and the proposed visual system model, a novel retina encoder (RE*) is proposed, which considers both ambiguity removal and miniature eye movements during fixation. Our simulation results suggest that VM requires miniature eye movements under control of the visual system to retrieve unambiguous patterns P2 corresponding to P1. For retina implant applications, RE* can be tuned to generate optimal ganglion cell codes for epiretinal stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/2/1/011

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 86

Metadata

Authors
Eckmiller, R., Neumann, D., & Baruth, O.
Venue
Journal of Neural Engineering
Published
2005-02-23
Volume
2
Issue
1
Pages
S91-S104
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2116074682
Cited by
86
References
5
FWCI
3.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tunable retina encoders for retina implants: why and how. https://app.cochat.ai/papers/10.1088/1741-2560/2/1/011
The paper
Eckmiller, R., Neumann, D., & Baruth, O. (2005). Tunable retina encoders for retina implants: why and how. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/2/1/011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.