The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A 232-Channel Epiretinal Stimulator ASIC
Abstract
This paper presents the architecture and design of a stimulator ASIC for a visual prosthesis. The circuit employs fully wireless operation and features 232 channels with a maximum of 116 parallel stimulations. The architecture is separated into shared global functions and locally distributed stimulation functions. High tissue impedance of epiretinal stimulation sets the need for high-voltage output compliance, which is typically as high as 22.5 V in this implementation. For implantation-ready design, full testability has been achieved, full ESD protection was implemented, and novel safety features were realized in order to combine highly flexible operation with maximum innocuousness for the patient. The overall stimulator occupies 22 mm2in a 0.35 HVCMOS technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“The amount of charge needed and the duration of the transfer depend on several factors, including the stimulation circuitry (constant voltage or current), shape of the stimulation waveform, frequency of stimulation, excitation threshold of the corresponding cells, as well as on the stimulating electrodes location, geo…”
BackgroundA low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Cited by
An Integrated 256-Channel Epiretinal Prosthesis
Chen, K., Yang, Z., Hoang, L., Weiland, J., Humayun, M., & Liu, W. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2055371 · Cited by 266
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
“tion for the electrode/LED terminals [48].”
BackgroundNoorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212
Self-citationAn active approach for charge balancing in functional electrical stimulation.
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2040277 · Cited by 170
Self-citationArfin, S. K., & Sarpeshkar, R. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2166072 · Cited by 133
Metadata
- Authors
- Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H.-J.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2007-12
- Volume
- 42
- Issue
- 12
- Pages
- 2946-2959
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2148483191
- Cited by
- 225
- References
- 3
- FWCI
- 7.09
- Type
- journal article
- Language
- nl
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 232-Channel Epiretinal Stimulator ASIC. https://app.cochat.ai/papers/10.1109/jssc.2007.908693
- The paper
- Ortmanns, M., Rocke, A., Gehrke, M., & Tiedtke, H.-J. (2007). A 232-Channel Epiretinal Stimulator ASIC. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2007.908693
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.