A method and technical equipment for an acute human trial to evaluate retinal implant technology
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper reports on methods and technical equipment to investigate the epiretinal stimulation of the retina in blind human subjects in acute trials. Current is applied to the retina through a thin, flexible microcontact film (microelectrode array) with electrode diameters ranging from 50 to 360 microm. The film is mounted in a custom-designed surgical tool that is hand-held by the surgeon during stimulation. The eventual goal of the work is the development of a chronically implantable retinal prosthesis to restore a useful level of vision to patients who are blind with outer retinal degenerations, specifically retinitis pigmentosa and macular degeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856 · cited 2×
“(Humayun et al 1996, Humayun et al 1999, Rizzo et al 2003a, 2003b, Humayun et al 2003).”
BackgroundResultRizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · cited 4×
“In recent years, two other research groups have published results of acute clinical trials for electrical stimulation of the retina (Humayun et al 1996, Humayun and de Juan 1998, Humayun et al 1999 and Rizzo et al 2003a, Rizzo et al 2003b).”
BackgroundMethodResultSelf-citationRetinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476 · cited 1×
“In these disorders, despite a nearly total loss of photoreceptors, there is relative preservation of the inner retinal neurons (Stone et al 1992, Santos et al 1997, Jones et al 2003, Marc and Jones 2003).”
BackgroundHumayun, M. S., & de Juan, E. (1998) · Eye · doi:10.1038/eye.1998.151 · Cited by 50
Cited by
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
“IOVS 2008;49:ARVO E-Abstract 1786.(5,10,50) –52 For epiretinal stimulation Humayun et al.”
BackgroundDevelopment of very large electrode arrays for epiretinal stimulation (VLARS)
Waschkowski, F., Hesse, S., Rieck, A. C., Lohmann, T., Brockmann, C., Laube, T., Bornfeld, N., Thumann, G., Walter, P., Mokwa, W., et al. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-11 · Cited by 43
Self-citation
Metadata
- Authors
- Hornig, R., Laube, T., Walter, P., Velikay-Parel, M., Bornfeld, N., Feucht, M., Akguel, H., Rössler, G., Alteheld, N., Notarp, D. L., Wyatt, J., & Richard, G.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2005-02-23
- Volume
- 2
- Issue
- 1
- Pages
- S129-S134
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2029642443
- Cited by
- 78
- References
- 4
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method and technical equipment for an acute human trial to evaluate retinal implant technology. https://app.cochat.ai/papers/10.1088/1741-2560/2/1/014
- The paper
- Hornig, R., Laube, T., Walter, P., Velikay-Parel, M., Bornfeld, N., Feucht, M., Akguel, H., Rössler, G., Alteheld, N., Notarp, D. L., Wyatt, J., & Richard, G. (2005). A method and technical equipment for an acute human trial to evaluate retinal implant technology. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/2/1/014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.