Limb-state feedback from ensembles of simultaneously recorded dorsal root ganglion neurons
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Functional electrical stimulation (FES) holds great potential for restoring motor functions after brain and spinal cord injury. Currently, most FES systems are under simple finite state control, using external sensors which tend to be bulky, uncomfortable and prone to failure. Sensory nerve signals offer an interesting alternative, with the possibility of continuous feedback control. To test feasibility, we recorded from ensembles of sensory neurons with microelectrode arrays implanted in the dorsal root ganglion (DRG) of walking cats. Limb position and velocity variables were estimated accurately (average R2 values >0.5) over a range of walking speeds (0.1-0.5 m s(-1)) using a linear combination of firing rates from 10 or more neurons. We tested the feasibility of sensory control of intraspinal FES by recording from DRG neurons during hindlimb movements evoked by intraspinal microstimulation of the lumbar spinal cord in an anesthetized cat. Although electrical stimulation generated artifacts, this problem was overcome by detecting and eliminating events that occurred synchronously across the array of microelectrodes. The sensory responses to limb movement could then be measured and decoded to generate an accurate estimate of the limb state. Multichannel afferent recordings may thus provide FES systems with the feedback needed for adaptive control and perturbation compensation, though long-term stability remains a challenge.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“…with the development of cortically controlled FES systems (Isaacs et al 2000, Taylor 1741-2560/07/030168+13$30.00 © 2007 IOP Publishing Ltd Printed in the UK S168 et al 2002, Schwartz 2004, Hochberg et al 2006) which promise to expand the repertoire and complexity of FEScontrolled functions.”
BackgroundInfluentialSuner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415 · cited 1×
“Other neural prosthetics researchers have also reported day-to-day variations or ‘drift’ in the population of neurons being recorded by chronically implanted microelectrode arrays (Suner et al 2005).”
BackgroundPeckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319 · cited 1×
“The first type comprises signals from parts of the body under normal voluntary control, for example shoulder and wrist to control FES of hand muscles (Graupe et al 1982, Peckham et al 2001).”
BackgroundLong-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · cited 2×
“Intraneural recording methods with longitudinal intrafascicular electrodes (LIFE) (Yoshida and Horch 1996) and penetrating microelectrode arrays ( Branner et al 2004 ) have also been tested in a variety of animal models.”
BackgroundSelf-citationGraupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205 · cited 2×
“The first type comprises signals from parts of the body under normal voluntary control, for example shoulder and wrist to control FES of hand muscles ( Graupe et al 1982, Peckham et al 2001).”
BackgroundEnsemble firing of muscle afferents recorded during normal locomotion in cats
Prochazka, A., & Gorassini, M. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.293bu.x · Cited by 177 · cited 2×
“Alpha– gamma coactivation may have contributed to this elevated firing (Loeb and Duysens 1979, Prochazka and Gorassini 1998).”
BackgroundAoyagi, Y., Stein, R. B., Branner, A., Pearson, K. G., & Normann, R. A. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00143-2 · Cited by 68
Self-citationPerspectives on the role of afferent signals in control of motor neuroprostheses
Johnson, K. O., Popović, D., Riso, R. R., Koris, M., Van Doren, C., & Kantor, C. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00003-6 · Cited by 16 · cited 1×
“Thus, the mechanosensory neurons found in the skin, muscles and joints may provide all of the kinematic and kinetic state information needed for FES control, and these neurons typically remain functional in patients who could use a motor prosthesis (Johnson et al 1995).”
Background
Cited by
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
“The signals obtained from simultaneous recordings of 8–10 single units can be combined to obtain high-fidelity estimates of limb position and velocity (49), and feedback of these estimates can be used for closed-loop control of electrical stimulation (50).”
MethodA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Kolarcik, C. L., Catt, K., Rost, E., Albrecht, I. N., Bourbeau, D., Du, Z., Kozai, T. D. Y., Luo, X., Weber, D. J., & Tracy Cui, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016008 · Cited by 126
“Although the DRG is an attractive site for recording or stimulating primary afferent neurons to provide sensory feedback [2, 47], studies investigating the tissue reaction in response to stimulation are lacking.”
BackgroundSelf-citationInterfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98
Self-citationKolarcik, C. L., Bourbeau, D., Azemi, E., Rost, E., Zhang, L., Lagenaur, C. F., Weber, D. J., & Cui, X. T. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.034 · Cited by 59
“For example, SC stimulation has been investigated for pain control [7] and restoration of motor functions [8, 9], while the DRG is an attractive site for recording or stimulating primary afferent neurons to provide sensory feedback [10, 11].”
BackgroundSelf-citation
Metadata
- Authors
- Weber, D. J., Stein, R. B., Everaert, D. G., & Prochazka, A.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2007-08-22
- Volume
- 4
- Issue
- 3
- Pages
- S168-S180
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2030275344
- Cited by
- 89
- References
- 8
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limb-state feedback from ensembles of simultaneously recorded dorsal root ganglion neurons. https://app.cochat.ai/papers/10.1088/1741-2560/4/3/s04
- The paper
- Weber, D. J., Stein, R. B., Everaert, D. G., & Prochazka, A. (2007). Limb-state feedback from ensembles of simultaneously recorded dorsal root ganglion neurons. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/4/3/s04
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.