Two-dimensional movement control using electrocorticographic signals in humans
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
We show here that a brain-computer interface (BCI) using electrocorticographic activity (ECoG) and imagined or overt motor tasks enables humans to control a computer cursor in two dimensions. Over a brief training period of 12-36 min, each of five human subjects acquired substantial control of particular ECoG features recorded from several locations over the same hemisphere, and achieved average success rates of 53-73% in a two-dimensional four-target center-out task in which chance accuracy was 25%. Our results support the expectation that ECoG-based BCIs can combine high performance with technical and clinical practicality, and also indicate promising directions for further research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 3×
“The experimental protocol combined current BCI methodology [1, 22, 2] with current understanding of task-related ECoG changes [23–28].”
BackgroundMethodSelf-citationNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“While a recent EEG-based study [2] and this paper demonstrate that subjects can make a good use of such non-intuitive imagery 9 , it appears likely that multi-dimensional control could be more efficiently achieved and potentially further improved by using more intuitive tasks such as directed actual…”
BackgroundBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Self-citationInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Self-citationCrone, N. (1998) · Brain · doi:10.1093/brain/121.12.2301 · Cited by 1,044
Mu and Beta Rhythm Topographies During Motor Imagery and Actual Movements
McFarland, D. J., Miner, L. A., Vaughan, T. M., & Wolpaw, J. R. (2000) · Brain Topography · doi:10.1023/a:1023437823106 · Cited by 860
Self-citationAn Introduction to Information Theory.
Mallows, C. L., & Reza, F. M. (1964) · The American Mathematical Monthly · doi:10.2307/2311344 · Cited by 771
Spectral Changes in Cortical Surface Potentials during Motor Movement
Miller, K. J., Leuthardt, E. C., Schalk, G., Rao, R. P. N., Anderson, N. R., Moran, D. W., Miller, J. W., & Ojemann, J. G. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.3886-06.2007 · Cited by 738
Self-citationA high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698 · cited 1×
“Signals recorded within cortex have higher fidelity and might support BCI systems that require less training than EEG-based systems.”
BackgroundStaba, R. J., Wilson, C. L., Bragin, A., Fried, I., & Engel, J. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1743 · Cited by 666
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663 · cited 1×
“Signals recorded within cortex have higher fidelity and might support BCI systems that require less training than EEG-based systems.”
BackgroundA Stereotactic Method of Anatomical Localization for Positron Emission Tomography
Fox, P. T., Perlmutter, J. S., & Raichle, M. E. (1985) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198501000-00025 · Cited by 572
Decoding two-dimensional movement trajectories using electrocorticographic signals in humans
Schalk, G., Kubánek, J., Miller, K. J., Anderson, N. R., Leuthardt, E. C., Ojemann, J. G., Limbrick, D., Moran, D., Gerhardt, L. A., & Wolpaw, J. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/012 · Cited by 527
Self-citationPfurtscheller, G., Graimann, B., Huggins, J. E., Levine, S. P., & Schuh, L. A. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00067-1 · Cited by 448
Spatial spectra of scalp EEG and EMG from awake humans
Freeman, W. J., Holmes, M. D., Burke, B. C., & Vanhatalo, S. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00045-2 · Cited by 370
Spatial filtering and neocortical dynamics: estimates of EEG coherence
Srinivasan, R., Nunez, P. L., & Silberstein, R. B. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686789 · Cited by 325
Visualization of significant ERD/ERS patterns in multichannel EEG and ECoG data
Graimann, B., Huggins, J. E., Levine, S. P., & Pfurtscheller, G. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00697-6 · Cited by 302
Electrocorticographic gamma activity during word production in spoken and sign language
Crone, N. E., Hao, L., Hart, J., Boatman, D., Lesser, R. P., Irizarry, R., & Gordon, B. (2001) · Neurology · doi:10.1212/wnl.57.11.2045 · Cited by 299
Lebedev, M. A., Carmena, J. M., O'Doherty, J. E., Zacksenhouse, M., Henriquez, C. S., Principe, J. C., & Nicolelis, M. A. L. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4088-04.2005 · Cited by 290
Electrocorticographic high gamma activity versus electrical cortical stimulation mapping of naming
Sinai, A., Bowers, C. W., Crainiceanu, C. M., Boatman, D., Gordon, B., Lesser, R. P., Lenz, F. A., & Crone, N. E. (2005) · Brain · doi:10.1093/brain/awh491 · Cited by 266
Electrocorticography-based brain computer Interface-the seattle experience
Leuthardt, E. C., Miller, K. J., Schalk, G., Rao, R. P. N., & Ojemann, J. G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875536 · Cited by 245
Self-citationShain, W., Spataro, L., Dilgen, J., Haverstick, K., Retterer, S., Isaacson, M., Saltzman, M., & Turner, J. N. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814800 · Cited by 227
Bowerman, B., Wonnacott, T. H., & Wonnacott, R. J. (1978) · Technometrics · doi:10.2307/1267655 · Cited by 217
Real-time functional brain mapping using electrocorticography
Miller, K. J., den Nijs, M., Shenoy, P., Miller, J. W., Rao, R. P. N., & Ojemann, J. G. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.029 · Cited by 176
Self-citationECoG factors underlying multimodal control of a brain-computer interface
Wilson, J. A., Felton, E. A., Garell, P. C., Schalk, G., & Williams, J. C. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875570 · Cited by 163
Self-citationFelton, E. A., Wilson, J. A., Williams, J. C., & Garell, P. C. (2007) · Journal of Neurosurgery · doi:10.3171/jns.2007.106.3.495 · Cited by 154
Self-citationMiller, K. J., Makeig, S., Hebb, A. O., Rao, R. P. N., den Nijs, M., & Ojemann, J. G. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.01.019 · Cited by 105
Self-citationMargalit, E., Weiland, J. D., Clatterbuck, R. E., Fujii, G. Y., Maia, M., Tameesh, M., Torres, G. F., D’Anna, S. A., Desai, S., Piyathaisere, D. V., et al. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00345-x · Cited by 96
Loeb, G. E., Walker, A. E., Uematsu, S., & Konigsmark, B. W. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110206 · Cited by 95
Leuthardt, E. C., Miller, K., Anderson, N. R., Schalk, G., Dowling, J., Miller, J., Moran, D. W., & Ojemann, J. G. (2007) · Operative Neurosurgery · doi:10.1227/01.neu.0000255413.70807.6e · Cited by 94
Self-citationTissue response to potential neuroprosthetic materials implanted subdurally
Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90103-7 · Cited by 91
Chapter 63 Development of neuromotor prostheses for humans
Donoghue, J. P., Nurmikko, A. V., Friehs, G. M., & Black, M. J. (2004) · Supplements to Clinical neurophysiology · doi:10.1016/s1567-424x(09)70399-x · Cited by 64
INTRACAROTID AMOBARBITAL PROCEDURE: The Wada Test
Trenerry, M. R., & Loring, D. W. (1995) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(25)00333-8 · Cited by 55
Evaluation of Electrode Array Material for Neural Prostheses
Bullara, L. A., Agnew, W. F., Yuen, T. G. H., Jacques, S., & Pudenz, R. H. (1979) · Neurosurgery · doi:10.1227/00006123-197912000-00006 · Cited by 45
Márquez-Chin, C., Popović, M. R., Thrasher, T. A., Cameron, T., Lozano, A. M., & Chen, R. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/014 · Cited by 31
Evaluation of electrode array material for neural prostheses
Bullara, L. A., Agnew, W. F., Yuen, T. G. H., Jacques, S., & Rh, P. (1979) · Neurosurgery · doi:10.1097/00006123-197912000-00006 · Cited by 6
Research works printed but not linked: 9
- Wolpaw J R, 2002, Electroencephalogr. Clin. Neurophysiol., 113, 767
- McFarland D J, 2006, Society for Neuroscience Abstracts Online
- Leuthardt E C, 2007, Neurosurgery, 60, 260
- Trenerry M R, 1995, Neuroimaging Clin. N Am., 5, 721
- Miller K J, 2007, Society for Neuroscience Abstracts Online
- Talairach J, 1988, Co-Planar Sterotaxic Atlas of the Human Brain
- 10.1111/j.1535-7511.2007.00155.x · doi:10.1111/j.1535-7511.2007.00155.x
- Schalk G, 2005, Society for Neuroscience Abstracts Online
- Schalk G, 2007, Society for Neuroscience Abstracts Online
Cited by
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Self-citationBrain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Self-citationFlexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Self-citationCortical activity during motor execution, motor imagery, and imagery-based online feedback
Miller, K. J., Schalk, G., Fetz, E. E., den Nijs, M., Ojemann, J. G., & Rao, R. P. N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913697107 · Cited by 622
Self-citation
Metadata
- Authors
- Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2008-02-01
- Volume
- 5
- Issue
- 1
- Pages
- 75-84
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1969957364
- Cited by
- 482
- References
- 40
- FWCI
- 22.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.