Two-dimensional movement control using electrocorticographic signals in humans
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
We show here that a brain-computer interface (BCI) using electrocorticographic activity (ECoG) and imagined or overt motor tasks enables humans to control a computer cursor in two dimensions. Over a brief training period of 12-36 min, each of five human subjects acquired substantial control of particular ECoG features recorded from several locations over the same hemisphere, and achieved average success rates of 53-73% in a two-dimensional four-target center-out task in which chance accuracy was 25%. Our results support the expectation that ECoG-based BCIs can combine high performance with technical and clinical practicality, and also indicate promising directions for further research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 3×
“The experimental protocol combined current BCI methodology [1, 22, 2] with current understanding of task-related ECoG changes [23–28].”
BackgroundMethodSelf-citationNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“While a recent EEG-based study [2] and this paper demonstrate that subjects can make a good use of such non-intuitive imagery 9 , it appears likely that multi-dimensional control could be more efficiently achieved and potentially further improved by using more intuitive tasks such as directed actual…”
BackgroundBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Self-citationInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Self-citationCrone, N. (1998) · Brain · doi:10.1093/brain/121.12.2301 · Cited by 1,044
Mu and Beta Rhythm Topographies During Motor Imagery and Actual Movements
McFarland, D. J., Miner, L. A., Vaughan, T. M., & Wolpaw, J. R. (2000) · Brain Topography · doi:10.1023/a:1023437823106 · Cited by 860
Self-citation
Research works printed but not linked: 9
- Wolpaw J R, 2002, Electroencephalogr. Clin. Neurophysiol., 113, 767
- McFarland D J, 2006, Society for Neuroscience Abstracts Online
- Leuthardt E C, 2007, Neurosurgery, 60, 260
- Trenerry M R, 1995, Neuroimaging Clin. N Am., 5, 721
- Miller K J, 2007, Society for Neuroscience Abstracts Online
- Talairach J, 1988, Co-Planar Sterotaxic Atlas of the Human Brain
- 10.1111/j.1535-7511.2007.00155.x · doi:10.1111/j.1535-7511.2007.00155.x
- Schalk G, 2005, Society for Neuroscience Abstracts Online
- Schalk G, 2007, Society for Neuroscience Abstracts Online
Cited by
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Self-citationBrain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Self-citationFlexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Self-citationCortical activity during motor execution, motor imagery, and imagery-based online feedback
Miller, K. J., Schalk, G., Fetz, E. E., den Nijs, M., Ojemann, J. G., & Rao, R. P. N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913697107 · Cited by 622
Self-citationCombrisson, E., & Jerbi, K. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.010 · Cited by 599
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
“…based on electroencephalography ( Wolpaw et al., 1998 ; Hwang et al., 2012 ; Spu¨ler et al., 2012 ), electrocorticography ( Leuthardt et al., 2004 ; Schalk et al., 2008 ; Moran, 2010 ; Brunner et al., 2011 ; Wang et al., 2013 ), and intracortical electrical signals ( Serruya et al., 2002 ; Taylor…”
A high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Self-citationSimeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Brain–Computer Interfaces Using Sensorimotor Rhythms: Current State and Future Perspectives
Yuan, H., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2312397 · Cited by 492
Recent advances in flexible sensors for wearable and implantable devices
Pang, C., Lee, C., & Suh, K. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.39461 · Cited by 457
Electroencephalographic (EEG) control of three-dimensional movement
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/3/036007 · Cited by 454
“…or two dimensions (Wolpaw et al 1991, 2002, Chapin et al 1999, Fetz 1999, Serruya et al 2002, Taylor et al 2002, Carmena et al 2003, Andersen et al 2004, Wolpaw and McFarland 1994, 2004, Leuthardt et al 2004, Hochberg et al 2006, Schalk et al 2008, Velliste et al 2008, Ganguly and Carmena 2009).”
BackgroundSelf-citationBrain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Self-citationAn Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler-Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 402
Self-citationRestoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Chestek, C. A., Gilja, V., Nuyujukian, P., Foster, J. D., Fan, J. M., Kaufman, M. T., Churchland, M. M., Rivera-Alvidrez, Z., Cunningham, J. P., Ryu, S. I., et al. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/045005 · Cited by 350
Allison, B. Z., & Neuper, C. (2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8_3 · Cited by 350
Long-term asynchronous decoding of arm motion using electrocorticographic signals in monkey
Chao (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00003 · Cited by 341
The brain–computer interface cycle
Gerven, M. V., Farquhar, J., Schaefer, R., Vlek, R., Geuze, J., Nijholt, A., Ramsey, N., Haselager, P., Vuurpijl, L., Gielen, S., et al. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/041001 · Cited by 329
Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
Bridging the Brain to the World: A Perspective on Neural Interface Systems
Donoghue, J. P. (2008) · Neuron · doi:10.1016/j.neuron.2008.10.037 · Cited by 294
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Self-citationDecoding flexion of individual fingers using electrocorticographic signals in humans
Kubánek, J., Miller, K. J., Ojemann, J. G., Wolpaw, J. R., & Schalk, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066001 · Cited by 285
Self-citationEEG-based brain–computer interfaces
McFarland, D. J., & Wolpaw, J. R. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.11.004 · Cited by 283
Self-citationDaly, J. J., Cheng, R., Rogers, J., Litinas, K., Hrovat, K., & Dohring, M. (2009) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0b013e3181c1fc0b · Cited by 274
Brain–computer interfaces for speech communication
Brumberg, J. S., Nieto-Castanon, A., Kennedy, P. R., & Guenther, F. H. (2010) · Speech Communication · doi:10.1016/j.specom.2010.01.001 · Cited by 267
Electrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256
“This result was consistent with previous studies that showed human movements could be inferred by using ECoGs.(3,4,28,29) It was suggested that the basic features of cortical processing with high gamma powers are preserved following cortical reorganization resulting from motor dysfunctions.”
ResultDecoding natural grasp types from human ECoG
Pistohl, T., Schulze-Bonhage, A., Aertsen, A., Mehring, C., & Ball, T. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.084 · Cited by 249
“…Leuthardt et al., 2004; Mehring et al., 2003; Pistohl et al., 2008; Schalk et al., 2007; Stark and Abeles, 2007), the ECoG has been proposed as a potential control signal for BMIs (e.g., Ball et al., 2004; Levine et al., 2000; Leuthardt et al., 2006;Mehring et al., 2004; Schalk et al., 2008a).”
BackgroundInfluentialFunctional priorities, assistive technology, and brain-computer interfaces after spinal cord injury
Collinger, J. L., Boninger, M. L., Bruns, T. M., Curley, K., Wang, W., & Weber, D. J. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.11.0213 · Cited by 248
Decoding spoken words using local field potentials recorded from the cortical surface
Kellis, S., Miller, K., Thomson, K., Brown, R., House, P., & Greger, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056007 · Cited by 235
“movement trajectories [27, 28], and other motor tasks [29, 30].”
BackgroundSelf-citationBrain-Computer Interface in Stroke: A Review of Progress
Silvoni, S., Ramos-Murguialday, A., Cavinato, M., Volpato, C., Cisotto, G., Turolla, A., Piccione, F., & Birbaumer, N. (2011) · Clinical EEG and Neuroscience · doi:10.1177/155005941104200410 · Cited by 223
Individualized localization and cortical surface-based registration of intracranial electrodes
Dykstra, A. R., Chan, A. M., Quinn, B. T., Zepeda, R., Keller, C. J., Cormier, J., Madsen, J. R., Eskandar, E. N., & Cash, S. S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.046 · Cited by 220
A Practical Guide to Brain–Computer Interfacing with BCI2000
Schalk, G., & Mellinger, J. (2010) · Springer eBooks · doi:10.1007/978-1-84996-092-2 · Cited by 216
Self-citationNeural Interface Technology for Rehabilitation: Exploiting and Promoting Neuroplasticity
Wang, W., Collinger, J. L., Perez, M. A., Tyler-Kabara, E. C., Cohen, L. G., Birbaumer, N., Brose, S. W., Schwartz, A. B., Boninger, M. L., & Weber, D. J. (2010) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2009.07.003 · Cited by 213
“ECoG (sometimes also called intracranial EEG) recently received considerable attention as a promising modality for BCI application.(34,35) ECoG recordings are often performed for patients with intractable epilepsy for presurgical brain mapping and seizure foci localization.”
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Real-time control of a prosthetic hand using human electrocorticography signals: Technical note
Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2011) · Journal of Neurosurgery · doi:10.3171/2011.1.jns101421 · Cited by 208
Machine-learning-based coadaptive calibration for brain-computer interfaces
Vidaurre, C., Sannelli, C., Müller, K.-R., & Blankertz, B. (2011) · Neural Computation · doi:10.1162/neco_a_00089 · Cited by 207
“( 2008 ), and Leuthardt, Freudenberg, Bundy, and Roland ( 2009 ) for ECoG-based BCIs and to Carmena et al.”
BackgroundWIMAGINE: Wireless 64-Channel ECoG Recording Implant for Long Term Clinical Applications
Mestais, C. S., Charvet, G., Sauter-Starace, F., Foerster, M., Ratel, D., & Benabid, A. L. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2333541 · Cited by 202
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
“Recently, ECoG signals have been used for 2-dimensional cursor control and to determine the timecourse of individual finger flexion [66,80].”
BackgroundMethodInfluentialFlint, R. D., Wright, Z. A., Scheid, M. R., & Slutzky, M. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056005 · Cited by 183
“Other groups have used a biofeedback approach to control a BMI with subdural (ECoG) or epidural signals [44–49].”
BackgroundKaya, M., Binli, M. K., Ozbay, E., Yanar, H., & Mishchenko, Y. (2018) · Scientific Data · doi:10.1038/sdata.2018.211 · Cited by 178
Zhuang, J., Truccolo, W., Vargas-Irwin, C., & Donoghue, J. P. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2047015 · Cited by 174
“We also note that, because nonstationarities in the brain are likely to happen at many different spatial and temporal scales, the issue of tuning stability and the need for adaptive decoders in neural prostheses are unlikely to be restricted to a particular type of neural signal, but should be common to all types (SUA…”
InfluentialOptimal spacing of surface electrode arrays for brain–machine interface applications
Slutzky, M. W., Jordan, L. R., Krieg, T., Chen, M., Mogul, D. J., & Miller, L. E. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026004 · Cited by 161
“We may, for example, be losing information by sampling ECoG with the standard 1 cm clinical electrode spacing.”
MethodInfluentialUsing the electrocorticographic speech network to control a brain–computer interface in humans
Leuthardt, E. C., Gaona, C., Sharma, M., Szrama, N., Roland, J., Freudenberg, Z., Solis, J., Breshears, J., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036004 · Cited by 161
“Up to now, ECoG signals have been used to achieve rapid acquisition of control in one-and two-dimensional cursor tasks in humans using actual and imagined motor movements (Leuthardt et al., 2004; Schalk et al., 2008a).”
BackgroundMethodResultInfluentialSelf-citationKim, S.-P., Simeral, J. D., Hochberg, L. R., Donoghue, J. P., Friehs, G. M., & Black, M. J. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2107750 · Cited by 160
“The majority of human BCIs have relied on the sensing of field potential signals recorded on the scalp using electroencephalography (EEG) [8]–[10] or electrocorticography (ECoG) signals directly from the cortical surface [11], [12].”
Distributed cortical adaptation during learning of a brain–computer interface task
Wander, J. D., Blakely, T., Miller, K. J., Weaver, K. E., Johnson, L. A., Olson, J. D., Fetz, E. E., Rao, R. P. N., & Ojemann, J. G. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221127110 · Cited by 157
“To investigate the role of distributed cortical networks in BCI skill acquisition, we recorded population-scale neural activity simultaneously from various locations across the cortex using electrocorticography (ECoG) while subjects performed a BCI task.”
MethodInfluentialSelf-citationGuo, L., Guvanasen, G. S., Liu, X., Tuthill, C., Nichols, T. R., & DeWeerth, S. P. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2192932 · Cited by 139
Human cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
Fifer, M. S., Acharya, S., Benz, H. L., Mollazadeh, M., Crone, N. E., & Thakor, N. V. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2175636 · Cited by 74
Moly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65
“…recordings Generally ECoG-based BCI studies are performed using temporary ECoG subdural grid implantation from 3 to 35 days post-surgery 10,12–15, 18, 23, The online closed-loop results presented a high stability level and were far above the realized chance level study across all experiments…”
ResultHiremath, S. V., Chen, W., Wang, W., Foldes, S., Yang, Y., Tyler-Kabara, E. C., Collinger, J. L., & Boninger, M. L. (2015) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2015.00040 · Cited by 53
“Rather, this method either remaps cortical activity into a different movement of a device, or maps cortical activity to device movement using arbitrary decoding weights (Fetz, 2007; Moritz et al., 2008; Schalk et al., 2008; Ganguly and Carmena, 2009; McFarland et al., 2010; Wang et al., 2013).”
BackgroundMethodInfluentialInner speech in motor cortex and implications for speech neuroprostheses
Kunz, E. M., Abramovich Krasa, B., Kamdar, F., Avansino, D. T., Hahn, N., Yoon, S., Singh, A., Nason-Tomaszewski, S. R., Card, N. S., Jude, J. J., et al. (2025) · Cell · doi:10.1016/j.cell.2025.06.015 · Cited by 55
High-density mapping of primate digit representations with a 1152-channel µECoG array
Kaiju, T., Inoue, M., Hirata, M., & Suzuki, T. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe245 · Cited by 42
“Previous studies have demonstrated that humans [7, 8] and nonhuman primates [9] can control external devices, such as computer cursors, by decoding the measured brain activity.”
BackgroundLong-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients
Larzabal, C., Bonnet, S., Costecalde, T., Auboiroux, V., Charvet, G., Chabardes, S., Aksenova, T., & Sauter-Starace, F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2003 · Cited by 37
“In case of BCI applications, BCI feature extraction is often based on the estimation of signal energy in the specific frequency bands (e.g. [1, 20]).”
The Layer 7 Cortical Interface: A Scalable and Minimally Invasive Brain–Computer Interface Platform
Hettick, M., Ho, E., Poole, A. J., Monge, M., Papageorgiou, D., Takahashi, K., LaMarca, M., Trietsch, D., Reed, K., Murphy, M., et al. (2022) · doi:10.1101/2022.01.02.474656 · Cited by 31
“…used advanced surface array techniques to correlate neural activity with motor function for the control of neural prostheses in paralyzed patients 7,84,85,93–96 , to achieve speech decoding in anarthric patients 6,19,80,86,97,98 , or for other applications of high-resolution electrocorticography…”
Background
Metadata
- Authors
- Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2008-02-01
- Volume
- 5
- Issue
- 1
- Pages
- 75-84
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1969957364
- Cited by
- 482
- References
- 40
- FWCI
- 22.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.