CoChat

Development and characterization of in vivo flexible electrodes compatible with large tissue displacements

Open access
Wester, B A, Lee, R H, LaPlaca, M C · 2009 · Journal of Neural Engineering
Cited by 91

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Electrical activity is the ultimate functional measure of neuronal tissue and recording that activity remains a key technical challenge in neuroscience. The mechanical mismatch between rigid electrodes and compliant brain tissue is a critical limitation in applications where movement is an inherent component. An electrode that permits recording of neural activity, while minimizing tissue disruption, is beneficial for applications that encompass both normal physiological movements and those which require consistent recording during large tissue displacements. In order to test the extreme of this range of movement, flexible electrodes were developed to record activity during and immediately following cortical impact in the rat. Photolithography techniques were used to fabricate flexible electrodes that were readily insertable into the brain using a parylene C base and gold conduction lines and contact pads, permitting custom geometry. We found that this electrode configuration retained mechanical and electrical integrity following both durability studies and large movements within the cortex. This novel flexible electrode configuration provides a novel platform for experimentally examining neuronal activity during a range of brain movements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/6/2/024002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 91

Metadata

Authors
Wester, B. A., Lee, R. H., & LaPlaca, M. C.
Venue
Journal of Neural Engineering
Published
2009-03-02
Volume
6
Issue
2
Pages
024002
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W2002343340
Cited by
91
References
1
FWCI
1.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and characterization of in vivo flexible electrodes compatible with large tissue displacements. https://app.cochat.ai/papers/10.1088/1741-2560/6/2/024002
The paper
Wester, B. A., Lee, R. H., & LaPlaca, M. C. (2009). Development and characterization of in vivo flexible electrodes compatible with large tissue displacements. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/6/2/024002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.