A high-speed BCI based on code modulation VEP
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Recently, electroencephalogram-based brain-computer interfaces (BCIs) have attracted much attention in the fields of neural engineering and rehabilitation due to their noninvasiveness. However, the low communication speed of current BCI systems greatly limits their practical application. In this paper, we present a high-speed BCI based on code modulation of visual evoked potentials (c-VEP). Thirty-two target stimuli were modulated by a time-shifted binary pseudorandom sequence. A multichannel identification method based on canonical correlation analysis (CCA) was used for target identification. The online system achieved an average information transfer rate (ITR) of 108 ± 12 bits min(-1) on five subjects with a maximum ITR of 123 bits min(-1) for a single subject.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“Brain–computer interface (BCI) systems establish a direct communication channel between the human brain and the external environment by translating human intentions into control signals [1], thereby providing a new communication channel to people with severe motor disabilities.”
BackgroundBin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773
Self-citationMultiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541
Brain-Computer Interfaces Based on Visual Evoked Potentials
Wang, Y., Gao, X., Hong, B., Jia, C., & Gao, S. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2008.923958 · Cited by 423
Self-citationThe brain response interface: communication through visually-induced electrical brain responses
Sutter, E. E. (1992) · Journal of Microcomputer Applications · doi:10.1016/0745-7138(92)90045-7 · Cited by 417
EEG-based communication: improved accuracy by response verification
Wolpaw, J. R., Ramoser, H., McFarland, D. J., & Pfurtscheller, G. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.712231 · Cited by 396
VEP-based brain-computer interfaces: time, frequency, and code modulations [Research Frontier
Bin, G., Gao, X., Wang, Y., Hong, B., & Gao, S. (2009) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2009.934562 · Cited by 256
Self-citationTonet, O., Marinelli, M., Citi, L., Rossini, P. M., Rossini, L., Megali, G., & Dario, P. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.015 · Cited by 94
Cited by
Chen, X., Wang, Y., Gao, S., Jung, T.-P., & Gao, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046008 · Cited by 805
Self-citationEEG-Based Brain-Computer Interfaces Using Motor-Imagery: Techniques and Challenges
Padfield, N., Zabalza, J., Zhao, H., Masero, V., & Ren, J. (2019) · Sensors · doi:10.3390/s19061423 · Cited by 596
Brain computer interface: control signals review
Ramadan, R. A., & Vasilakos, A. V. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.024 · Cited by 551
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Riemannian geometry for EEG-based brain-computer interfaces; a primer and a review
Congedo, M., Barachant, A., & Bhatia, R. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1297192 · Cited by 456
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Self-citationNakanishi, M., Wang, Y., Wang, Y.-T., & Jung, T.-P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0140703 · Cited by 376
Self-citationA HIGH-SPEED BRAIN SPELLER USING STEADY-STATE VISUAL EVOKED POTENTIALS
NAKANISHI, M., WANG, Y., WANG, Y.-T., MITSUKURA, Y., & JUNG, T.-P. (2014) · International Journal of Neural Systems · doi:10.1142/s0129065714500191 · Cited by 369
Self-citationP300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
L1-Regularized Multiway Canonical Correlation Analysis for SSVEP-Based BCI
Zhang, Y., Zhou, G., Jin, J., Wang, M., Wang, X., & Cichocki, A. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279680 · Cited by 267
Brain-Computer Interface: Advancement and Challenges
Mridha, M. F., Das, S. C., Kabir, M. M., Lima, A. A., Islam, M. R., & Watanobe, Y. (2021) · Sensors · doi:10.3390/s21175746 · Cited by 263
Development of an SSVEP-based BCI spelling system adopting a QWERTY-style LED keyboard
Hwang, H.-J., Lim, J.-H., Jung, Y.-J., Choi, H., Lee, S. W., & Im, C.-H. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.04.011 · Cited by 251
“A recent study introduced a high-speed SSVEP BCI system that also had the same number of visual stimuli as the number of targets, and thereby could produce one complete command per each target selection (Bin et al., 2011).”
InfluentialXu, M., Xiao, X., Wang, Y., Qi, H., Jung, T.-P., & Ming, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2799661 · Cited by 227
“Very few studies tried the SDMA [52] or CDMA schemes [53]–[56], and no study has ever mixed”
BackgroundSelf-citationA novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 225
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
BETA: A Large Benchmark Database Toward SSVEP-BCI Application
Liu, B., Huang, X., Wang, Y., Chen, X., & Gao, X. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00627 · Cited by 209
“These spatial filters or projection direction can be learned by exploiting individual training template (Bin et al., 2011), reference signal optimization (Zhang et al., 2013), interfrequency variation (Yin et al., 2015), and ensemble reference signals (Nakanishi et al., 2014; Chen et al., 2015a) in…”
BackgroundMethodSelf-citationMugler, E. M., Patton, J. L., Flint, R. D., Wright, Z. A., Schuele, S. U., Rosenow, J., Shih, J. J., Krusienski, D. J., & Slutzky, M. W. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035015 · Cited by 192
Spüler, M., Rosenstiel, W., & Bogdan, M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0051077 · Cited by 177
“When using the method by Bin et al. [4] an average accuracy of 88.48% was achieved.”
MethodInfluentialNon-Invasive Brain-Computer Interfaces: State of the Art and Trends
Edelman, B. J., Zhang, S., Schalk, G., Brunner, P., Müller-Putz, G., Guan, C., & He, B. (2025) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2024.3449790 · Cited by 170
“For example, in the case of t-VEPs and c-VEPs, different stimuli are presented at varying delays from trial onset, which can then be detected in the time-domain EEG signal [57], [58], [59].”
Yuan, P., Gao, X., Allison, B., Wang, Y., Bin, G., & Gao, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026014 · Cited by 160
“The BCI provides cues that instruct the user when to choose a target character, when to perform mental tasks to send a message or command and perhaps when to rest or perform other actions (Birbaumer et al 1999, Wolpaw et al 2002, Pfurtscheller and Neuper 2001, Boostani et al 2007, Bin et al 2011).”
BackgroundMethodSelf-citationTo train or not to train? A survey on training of feature extraction methods for SSVEP-based BCIs
Zerafa, R., Camilleri, T., Falzon, O., & Camilleri, K. P. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaca6e · Cited by 160
Spatial Filtering for EEG-Based Regression Problems in Brain–Computer Interface (BCI)
Wu, D., King, J.-T., Chuang, C.-H., Lin, C.-T., & Jung, T.-P. (2018) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2017.2688423 · Cited by 116
Höhne, J., Holz, E., Staiger-Sälzer, P., Müller, K.-R., Kübler, A., & Tangermann, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104854 · Cited by 85
“Different types of brain signals can be used to control a BCI and a vast amount of studies have demonstrated the proof of concept, showing that healthy users are able to control noninvasive BCIs with a high accuracy and a communication rate of up to 100 bits/ min [3].”
BackgroundA New Generation of Brain-Computer Interface Based on Riemannian Geometry
Congedo, M., Barachant, A., & Andreev, A. (2013) · arXiv · doi:10.48550/arxiv.1310.8115 · Cited by 69
“ing the Fourier cospectra at the F flickering frequencies. Note that if the phase of the SSVEP is known thanks to precise data tagging, as it is done in Jia et al. (2011), or code modulation is used (Bin et al., 2011), one can exploit both the frequential and the temporal information, constructing a super trial mixing…”
Method
Metadata
- Authors
- Bin, G., Gao, X., Wang, Y., Li, Y., Hong, B., & Gao, S.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-03-24
- Volume
- 8
- Issue
- 2
- Pages
- 025015
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2081020044
- Cited by
- 305
- References
- 8
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.