Carbon nanotube composite coating of neural microelectrodes preferentially improves the multiunit signal-to-noise ratio
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Extracellular metal microelectrodes are widely used to record single neuron activity in vivo. However, their signal-to-noise ratio (SNR) is often far from optimal due to their high impedance value. It has been recently reported that carbon nanotube (CNT) coatings may decrease microelectrode impedance, thus improving their performance. To tease out the different contributions to SNR of CNT-coated microelectrodes we carried out impedance and noise spectroscopy measurements of platinum/tungsten microelectrodes coated with a polypyrrole-CNT composite. Neuronal signals were recorded in vivo from rat cortex by employing tetrodes with two recording sites coated with polypyrrole-CNT and the remaining two left untreated. We found that polypyrrole-CNT coating significantly reduced the microelectrode impedance at all neuronal signal frequencies (from 1 to 10 000 Hz) and induced a significant improvement of the SNR, up to fourfold on average, in the 150-1500 Hz frequency range, largely corresponding to the multiunit frequency band. An equivalent circuit, previously proposed for porous conducting polymer coatings, reproduced the impedance spectra of our coated electrodes but could not explain the frequency dependence of SNR improvement following polypyrrole-CNT coating. This implies that neither the neural signal amplitude, as recorded by a CNT-coated metal microelectrode, nor noise can be fully described by the equivalent circuit model we used here and suggests that a more detailed approach may be needed to better understand the signal propagation at the electrode-solution interface. Finally, the presence of significant noise components that are neither thermal nor electronic makes it difficult to establish a direct relationship between the actual electrode noise and the impedance spectra.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buzsáki, G. (2006) · doi:10.1093/acprof:oso/9780195301069.001.0001 · Cited by 4,873
Gray, C. M., König, P., Engel, A. K., & Singer, W. (1989) · Nature · doi:10.1038/338334a0 · Cited by 4,183
The structural organization of layer IV in the somatosensory region (S I) of mouse cerebral cortex
Woolsey, T. A., & Van der Loos, H. (1970) · Brain Research · doi:10.1016/0006-8993(70)90079-x · Cited by 2,254
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
Fries, P., Nikolić, D., & Singer, W. (2007) · Trends in Neurosciences · doi:10.1016/j.tins.2007.05.005 · Cited by 1,044
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 2×
“This discrepancy between the decrease in the microelectrode impedance real part and the rms noise contradicts the view that the impedance determines most of the microelectrode performance [1, 14, 16, 20, 25].”
Background
Cited by
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Organic Bioelectronics: Bridging the Signaling Gap between Biology and Technology
Simon, D. T., Gabrielsson, E. O., Tybrandt, K., & Berggren, M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00146 · Cited by 568
Kuzum, D., Takano, H., Shim, E., Reed, J. C., Juul, H., Richardson, A. G., de Vries, J., Bink, H., Dichter, M. A., Lucas, T. H., et al. (2014) · Nature Communications · doi:10.1038/ncomms6259 · Cited by 546
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
Gulino, M., Kim, D., Pané, S., Santos, S. D., & Pêgo, A. P. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00689 · Cited by 159
Metadata
- Authors
- Baranauskas, G., Maggiolini, E., Castagnola, E., Ansaldo, A., Mazzoni, A., Angotzi, G. N., Vato, A., Ricci, D., Panzeri, S., & Fadiga, L.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-10-01
- Volume
- 8
- Issue
- 6
- Pages
- 066013
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2144248542
- Cited by
- 97
- References
- 8
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon nanotube composite coating of neural microelectrodes preferentially improves the multiunit signal-to-noise ratio. https://app.cochat.ai/papers/10.1088/1741-2560/8/6/066013
- The paper
- Baranauskas, G., Maggiolini, E., Castagnola, E., Ansaldo, A., Mazzoni, A., Angotzi, G. N., Vato, A., Ricci, D., Panzeri, S., & Fadiga, L. (2011). Carbon nanotube composite coating of neural microelectrodes preferentially improves the multiunit signal-to-noise ratio. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/6/066013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.