CoChat

Microfabricated Optically-Pumped Magnetometers for Biomagnetic Applications

Open access
Knappe, Svenja, Alem, Orang, Sheng, Dong, Kitching, John · 2016 · Journal of Physics: Conference Series
Cited by 49

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

We report on the progress in developing microfabricated optically-pumped magnetometer arrays for imaging applications. We have improved our sensitivities by several orders of magnitude in the last ten years. Now, our zero-field magnetometers reach noise values below 15 fT/Hz 1/2 . Recently, we have also developed gradiometers to reject ambient magnetic field noise. We have built several imaging arrays and validated them for biomedical measurements of brain and heart activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1742-6596/723/1/012055

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 49

Metadata

Authors
Knappe, S., Alem, O., Sheng, D., & Kitching, J.
Venue
Journal of Physics: Conference Series
Published
2016-06
Volume
723
Pages
012055
ISSN
  • 1742-6588 (ISSN-L)
  • 1742-6596
OpenAlex
W2471469599
Cited by
49
References
4
FWCI
19.71
Type
conference paper
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microfabricated Optically-Pumped Magnetometers for Biomagnetic Applications. https://app.cochat.ai/papers/10.1088/1742-6596/723/1/012055
The paper
Knappe, S., Alem, O., Sheng, D., & Kitching, J. (2016). Microfabricated Optically-Pumped Magnetometers for Biomagnetic Applications. Journal of Physics: Conference Series. https://doi.org/10.1088/1742-6596/723/1/012055

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.