Electrospun polydioxanone–elastin blends: potential for bioresorbable vascular grafts
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
An electrospun cardiovascular graft composed of polydioxanone (PDO) and elastin has been designed and fabricated with mechanical properties to more closely match those of native arterial tissue, while remaining conducive to tissue regeneration. PDO was chosen to provide mechanical integrity to the prosthetic, while elastin provides elasticity and bioactivity (to promote regeneration in vitro/in situ). It is the elastic nature of elastin that dominates the low-strain mechanical response of the vessel to blood flow and prevents pulsatile energy from being dissipated as heat. Uniaxial tensile and suture retention tests were performed on the electrospun grafts to demonstrate the similarities of the mechanical properties between the grafts and native vessel. Dynamic compliance measurements produced values that ranged from 1.2 to 5.6%/100 mmHg for a set of three different mean arterial pressures. Results showed the 50:50 ratio to closely mimic the compliance of native femoral artery, while grafts that contained less elastin exceeded the suture retention strength of native vessel. Preliminary cell culture studies showed the elastin-containing grafts to be bioactive as cells migrated through their full thickness within 7 days, but failed to migrate into pure PDO scaffolds. Electrospinning of the PDO and elastin-blended composite into a conduit for use as a small diameter vascular graft has extreme potential and warrants further investigation as it thus far compares favorably to native vessel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospinning of Collagen Nanofibers
Matthews, J. A., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2002) · Biomacromolecules · doi:10.1021/bm015533u · Cited by 2,251
Self-citation(1985) · Annals of Internal Medicine · doi:10.7326/0003-4819-103-3-486_3 · Cited by 2,056
Cardiovascular Solid Mechanics: Cells, Tissues, and Organs
Humphrey, J., & Epstein, M. (2002) · Applied Mechanics Reviews · doi:10.1115/1.1497492 · Cited by 1,159
Strength of biological materials
Yamada, H., & Evans, F. G. (1970) · Cited by 1,136
Cardiovascular Solid Mechanics: Cells, Tissues, and Organs
Humphrey, J. D. (2002) · Springer eBooks · doi:10.1007/978-0-387-21576-1 · Cited by 1,027
Electrospinning of collagen and elastin for tissue engineering applications
Buttafoco, L., Kolkman, N. G., Engbers-Buijtenhuijs, P., Poot, A. A., Dijkstra, P. J., Vermes, I., & Feijen, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.06.024 · Cited by 627
Strength of biological materials
Roberts, V. L. (1971) · Journal of Biomechanics · doi:10.1016/0021-9290(71)90027-3 · Cited by 566
Electrospinning collagen and elastin: preliminary vascular tissue engineering
Boland, E. (2004) · Frontiers in Bioscience · doi:10.2741/1313 · Cited by 537
Current status of prosthetic bypass grafts: A review
Kannan, R. Y., Salacinski, H. J., Butler, P. E., Hamilton, G., & Seifalian, A. M. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30247 · Cited by 527
Boland, E., Wnek, G., Simpson, D., Pawlowski, K., & Bowlin, G. (2001) · Journal of Macromolecular Science, Part A · doi:10.1081/ma-100108380 · Cited by 464
Self-citationFung, Y. C. (1984) · Springer eBooks · doi:10.1007/978-1-4757-3884-1 · Cited by 390
Generation of Synthetic Elastin-Mimetic Small Diameter Fibers and Fiber Networks
Huang, L., McMillan, R. A., Apkarian, R. P., Pourdeyhimi, B., Conticello, V. P., & Chaikof, E. L. (2000) · Macromolecules · doi:10.1021/ma991858f · Cited by 352
Electrospinning polydioxanone for biomedical applications
Boland, E. D., Coleman, B. D., Barnes, C. P., Simpson, D. G., Wnek, G. E., & Bowlin, G. L. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.003 · Cited by 302 · cited 2×
“The strain at break trends were consistent with previous uniaxial testing performed on PDO scaffolds [8].”
ResultSelf-citationCompliance properties of conduits used in vascular reconstruction
Tai, N. R., Salacinski, H. J., Edwards, A., Hamilton, G., & Seifalian, A. M. (2000) · Journal of British Surgery · doi:10.1046/j.1365-2168.2000.01566.x · Cited by 267
The ideal small arterial substitute: a search for the Holy Grail?
Conte, M. S. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.43 · Cited by 245
Wyngaarden, J. B. (1980) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)75151-7 · Cited by 244
Electrospinning of Collagen Type II: A Feasibility Study
Matthews, J. A., Boland, E. D., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2003) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911503018002003 · Cited by 193
Self-citationMechanical properties of electrospun fibrinogen structures
McManus, M. C., Boland, E. D., Koo, H. P., Barnes, C. P., Pawlowski, K. J., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2006) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.09.008 · Cited by 188
Self-citationNew Prostheses for Use in Bypass Grafts with Special Emphasis on Polyurethanes
Tiwari, A., Salacinski, H. J., Seifalian, A. M., & Hamilton, G. (2002) · Cardiovascular Surgery · doi:10.1016/s0967-2109(02)00004-2 · Cited by 167
Incorporation of Intact Elastin Scaffolds in Tissue-Engineered Collagen-Based Vascular Grafts
Berglund, J. D., Nerem, R. M., & Sambanis, A. (2004) · Tissue Engineering · doi:10.1089/ten.2004.10.1526 · Cited by 141
Cecil textbook of medicine, 22nd edition
Otten, E. J. (2005) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2004.10.006 · Cited by 129
Biologic and Synthetic Vascular Prostheses
Stanley, J. C. (1982) · Cited by 124
Stitzel, J. D., Pawlowski, K. J., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2001) · Journal of Biomaterials Applications · doi:10.1106/u2uu-m9qh-y0bb-5gyl · Cited by 120
Self-citationTissue Engineering And Biodegradable Equivalents, Scientific And Clinical Applications
(2002) · Routledge eBooks · doi:10.4324/9780203910672 · Cited by 120
Tiwari, A., Cheng, K. S., Salacinski, H. J., Hamilton, G., & Seifalian, A. M. (2003) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.2002.1810 · Cited by 115 · cited 1×
“In addition, the occurrence of intimal hyperplasia has been closely tied to the mismatch of graft and adjacent arterial compliance [3, 4, 6, 19].”
BackgroundBuijtenhuijs, P., Buttafoco, L., Poot, A. A., Daamen, W. F., Van Kuppevelt, T. H., Dijkstra, P. J., De Vos, R. A. I., Sterk, L. M. T., Geelkerken, B. R. H., Feijen, J., et al. (2004) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20030105 · Cited by 114
Replacement Arteries Made to Order
Niklason, L. E. (1999) · Science · doi:10.1126/science.286.5444.1493 · Cited by 98
Catanese, J., Cooke, D. L., Maas, C. S., & Pruitt, L. A. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:2<187::aid-jbm13>3.0.co;2-m · Cited by 75
The Arterial Circulation: Physical Principles and Clinical Applications
Li, J. K.-J. (2000) · Medical Entomology and Zoology · Cited by 70
Fung, Y. C. (1997) · Springer eBooks · doi:10.1007/978-1-4757-2696-1_3 · Cited by 51
The Arterial Circulation: Physical Principles and Clinical Applications: J.K-J. Li
Parker, K. H. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00054-0 · Cited by 48
Pathophysiology of ischaemia-reperfusion injury
Carden, D. L., & Granger, D. N. (2000) · The Journal of Pathology · doi:10.1002/(sici)1096-9896(200002)190:3 · Cited by 5
Cited by
Nanofiber technology: Designing the next generation of tissue engineering scaffolds
Barnes, C. P., Sell, S. A., Boland, E. D., Simpson, D. G., & Bowlin, G. L. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.04.022 · Cited by 1,141
Self-citationSell, S. A., Wolfe, P. S., Garg, K., McCool, J. M., Rodriguez, I. A., & Bowlin, G. L. (2010) · Polymers · doi:10.3390/polym2040522 · Cited by 578
Self-citationSell, S. A., McClure, M. J., Garg, K., Wolfe, P. S., & Bowlin, G. L. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.07.012 · Cited by 491
Self-citationElectrospinning jets and nanofibrous structures
Garg, K., & Bowlin, G. L. (2011) · Biomicrofluidics · doi:10.1063/1.3567097 · Cited by 474
Self-citationGarg, K., Pullen, N. A., Oskeritzian, C. A., Ryan, J. J., & Bowlin, G. L. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.02.065 · Cited by 457
Self-citation
Metadata
- Authors
- Sell, S. A., McClure, M. J., Barnes, C. P., Knapp, D. C., Walpoth, B. H., Simpson, D. G., & Bowlin, G. L.
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2006-05-04
- Volume
- 1
- Issue
- 2
- Pages
- 72-80
- ISSN
- 1748-6041 (ISSN-L)
- 1748-605X
- OpenAlex
- W1987468690
- Cited by
- 216
- References
- 32
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.