Injectable hydrogel materials for spinal cord regeneration: a review
Open accessThe DOI matches its Crossref record; 152 of the 152 references it cites were found in a registry or an index.
Abstract
Spinal cord injury (SCI) presents a complex regenerative problem due to the multiple facets of growth inhibition that occur following trauma to the cord parenchyma and stroma. Clinically, SCI is further complicated by the heterogeneity in the size, shape and extent of human injuries. Many of these injuries do not breach the dura mater and have continuous viable axons through the injury site that can later lead to some degree of functional recovery. In these cases, surgical manipulation of the spinal cord by implanting a preformed scaffold or drug delivery device may lead to further damage. Given these circumstances, in situ-forming scaffolds are an attractive approach for SCI regeneration. These synthetic and natural polymers undergo a rapid transformation from liquid to gel upon injection into the cord tissue, conforming to the individual lesion site and directly integrating with the host tissue. Injectable materials can be formulated to have mechanical properties that closely match the native spinal cord extracellular matrix, and this may enhance axonal ingrowth. Such materials can also be loaded with cellular and molecular therapeutics to modulate the wound environment and enhance regeneration. This review will focus on the current status of in situ-forming materials for spinal cord repair. The advantages of, and requirements for, such polymers will be presented, and examples of the behavior of such systems in vitro and in vivo will be presented. There are helpful lessons to be learned from the investigations of injectable hydrogels for the treatment of SCI that apply to the use of these biomaterials for the treatment of lesions in other central nervous system tissues and in organs comprising other tissue types.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382 · cited 1×
“Additionally, the mechanical properties of substrates have a profound effect on cell behavior especially in the CNS [64, 69, 70].”
BackgroundHydrogels in drug delivery: Progress and challenges
Hoare, T. R., & Kohane, D. S. (2008) · Polymer · doi:10.1016/j.polymer.2008.01.027 · Cited by 3,776
Cell Movement Is Guided by the Rigidity of the Substrate
Lo, C.-M., Wang, H.-B., Dembo, M., & Wang, Y.-L. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76279-5 · Cited by 3,289 · cited 1×
“down gradients in stiffness and fibroblasts, implicated in mesenchymal scarring, preferentially migrate back toward stiffer areas of patterned hydrogels [74–76].”
BackgroundMechanisms and Genes of Cellular Suicide
Steller, H. (1995) · Science · doi:10.1126/science.7878463 · Cited by 2,479
Alginate hydrogels as synthetic extracellular matrix materials
Rowley, J. A., Madlambayan, G., & Mooney, D. J. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00107-0 · Cited by 2,342
Selective Differentiation of Neural Progenitor Cells by High-Epitope Density Nanofibers
Silva, G. A., Czeisler, C., Niece, K. L., Beniash, E., Harrington, D. A., Kessler, J. A., & Stupp, S. I. (2004) · Science · doi:10.1126/science.1093783 · Cited by 2,169
David, S., & Aguayo, A. J. (1981) · Science · doi:10.1126/science.6171034 · Cited by 1,683
Mechanical Properties of Lungs
Mead, J. (1961) · Physiological Reviews · doi:10.1152/physrev.1961.41.2.281 · Cited by 1,636
Reactive Astrocytes Protect Tissue and Preserve Function after Spinal Cord Injury
Faulkner, J. R., Herrmann, J. E., Woo, M. J., Tansey, K. E., Doan, N. B., & Sofroniew, M. V. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.3547-03.2004 · Cited by 1,598
Glial inhibition of CNS axon regeneration
Yiu, G., & He, Z. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1956 · Cited by 1,495
Cited by
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Self-Healing Injectable Hydrogels for Tissue Regeneration
Bertsch, P., Diba, M., Mooney, D. J., & Leeuwenburgh, S. C. G. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00179 · Cited by 892
Chitosan based hydrogels and their applications for drug delivery in wound dressings: A review
Hamedi, H., Moradi, S., Hudson, S. M., & Tonelli, A. E. (2018) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2018.06.114 · Cited by 759
Biopolymer nanofibrils: Structure, modeling, preparation, and applications
Ling, S., Chen, W., Fan, Y., Zheng, K., Jin, K., Yu, H., Buehler, M. J., & Kaplan, D. L. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.004 · Cited by 463
Bioprinting: From Tissue and Organ Development to in Vitro Models
Mota, C., Camarero-Espinosa, S., Baker, M. B., Wieringa, P., & Moroni, L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00789 · Cited by 345
An Introduction to Hydrogels and Some Recent Applications
Bahram, M., Mohseni, N., & Moghtader, M. (2016) · Emerging Concepts in Analysis and Applications of Hydrogels · doi:10.5772/64301 · Cited by 322
Hydrogel as a bioactive material to regulate stem cell fate
Tsou, Y.-H., Khoneisser, J., Huang, P.-C., & Xu, X. (2016) · Bioactive Materials · doi:10.1016/j.bioactmat.2016.05.001 · Cited by 317
Stimuli-Responsive, Pentapeptide, Nanofiber Hydrogel for Tissue Engineering
Tang, J. D., Mura, C., & Lampe, K. J. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b13363 · Cited by 302
Remote Magnetic Orientation of 3D Collagen Hydrogels for Directed Neuronal Regeneration
Antman-Passig, M., & Shefi, O. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b00131 · Cited by 283
Cai, L., Dewi, R. E., & Heilshorn, S. C. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201403631 · Cited by 270
Hong, L. T. A., Kim, Y.-M., Park, H. H., Hwang, D. H., Cui, Y., Lee, E. M., Yahn, S., Lee, J. K., Song, S.-C., & Kim, B. G. (2017) · Nature Communications · doi:10.1038/s41467-017-00583-8 · Cited by 252
Recent Progress in Biopolymer-Based Hydrogel Materials for Biomedical Applications
Mahmood, A., Patel, D., Hickson, B., DesRochers, J., & Hu, X. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23031415 · Cited by 218
“By combining two polymers, an interpenetrating network (IPN) can be created, provided that one of them is already present in the solution [9,14].”
BackgroundMethodInfluentialOmidinia‐Anarkoli, A., Boesveld, S., Tuvshindorj, U., Rose, J. C., Haraszti, T., & De Laporte, L. (2017) · Small · doi:10.1002/smll.201702207 · Cited by 210
Drug delivery, cell-based therapies, and tissue engineering approaches for spinal cord injury
Kabu, S., Gao, Y., Kwon, B. K., & Labhasetwar, V. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.08.060 · Cited by 188
“Multiple studies have utilized engineered hydrogels to release neurotrophins and growth factors directly into the SCI lesion and demonstrated supplementary exogenous neurotrophins such as NT-3, VEGF, GDNF, NGF, and BDNF could facilitate locomotive recovery in SCI (96, 97).”
BackgroundInjectable Extracellular Matrix Hydrogels as Scaffolds for Spinal Cord Injury Repair
Tukmachev, D., Forostyak, S., Koci, Z., Zaviskova, K., Vackova, I., Vyborny, K., Sandvig, I., Sandvig, A., Medberry, C. J., Badylak, S. F., et al. (2016) · Tissue Engineering Part A · doi:10.1089/ten.tea.2015.0422 · Cited by 160
“In addition to these approaches, tissue engineered scaffolds play an important role in providing supportive substrates that contribute to replacing lost tissue and re-establishing damaged connections after SCI (4-7).”
Conductive Scaffolds for Cardiac and Neuronal Tissue Engineering: Governing Factors and Mechanisms
Burnstine‐Townley, A., Eshel, Y., & Amdursky, N. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201901369 · Cited by 160
Design of three-dimensional engineered protein hydrogels for tailored control of neurite growth
Lampe, K. J., Antaris, A. L., & Heilshorn, S. C. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.10.033 · Cited by 158
“The neurons responsible for signal transmission have limited regenerative potential to bridge large tissue defects and are rarely able to reestablish distant axonal connections [1,2].”
Yildirimer, L., & Seifalian, A. M. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.04.014 · Cited by 98
Metadata
- Authors
- Macaya, D., & Spector, M.
- Venue
- Biomedical Materials
- Publisher
- IOP Publishing
- Published
- 2012-01-13
- Volume
- 7
- Issue
- 1
- Pages
- 012001
- ISSN
- 1748-6041 (ISSN-L)
- 1748-605X
- OpenAlex
- W2111199947
- Cited by
- 278
- References
- 152
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.