CoChat

The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MS

Ligor, T, Ligor, M, Amann, A, Ager, C, Bachler, M, Dzien, A, Buszewski, B · 2008 · Journal of Breath Research
Cited by 149

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We analysed breath and inhaled room air samples from 39 healthy volunteers (28 non-smokers, 8 smokers and 3 ex-smokers) by SPME-GC-MS. Mixed expiratory and indoor air samples were collected in freshly cleaned Tedlar bags. Eighteen millilitres of each sample were transferred into sealed, evacuated glass vials, preconcentrated by solid-phase microextraction (SPME, carboxen/polydimethylsiloxane) and investigated by gas chromatography with mass spectrometric detection (GC-MS). For the unequivocal identification of potential marker compounds, pure calibration mixtures of reference compounds (depending on commercial availability) were prepared to determine the retention time and mass spectra with respect to our analytical setting. Applying the adapted SPME-GC/MS method with limit of detection in the high ppb range (0.05-15.00 ppb), we succeeded in identifying altogether 38 compounds with concentrations in exhaled breath being at least 50% higher than concentration in inhaled air. From these 38 compounds, 31 were identified not only by the spectral library match but also by retention time of standards. A comparison of retention times and spectrum obtained for standards and determined compounds was performed. We found hydrocarbons (isoprene, 2-pentene, 2-methyl-1-pentene, benzene, toluene, p-cymene, limonene, 2,4-dimethylheptane, n-butane), ketones (acetone, hydroxypropanone, methylvinyl ketone), ethers (dimethyl ether, 1,3-dioxolane), esters (ethyl acetate), aldehydes (propanal, hexanal, heptanal, acrolein) and alcohols (ethanol, 2-metoxyethanol, isopropyl alcohol, 2,2,3,3- tetramethylcyclopropanemethanol, 3,4-dimethylcyclohexanol). Proper identification of compounds in different cohorts of patients and volunteers is the base for further investigation of origin, biochemical background and distribution of potential breath biomarkers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1752-7155/2/4/046006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 149

Metadata

Authors
Ligor, T., Ligor, M., Amann, A., Ager, C., Bachler, M., Dzien, A., & Buszewski, B.
Venue
Journal of Breath Research
Published
2008-10-15
Volume
2
Issue
4
Pages
046006
ISSN
  • 1752-7155 (ISSN-L)
  • 1752-7163
OpenAlex
W1993125867
Cited by
149
References
1
FWCI
5.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MS. https://app.cochat.ai/papers/10.1088/1752-7155/2/4/046006
The paper
Ligor, T., Ligor, M., Amann, A., Ager, C., Bachler, M., Dzien, A., & Buszewski, B. (2008). The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MS. Journal of Breath Research. https://doi.org/10.1088/1752-7155/2/4/046006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.