The analysis of healthy volunteers' exhaled breath by the use of solid-phase microextraction and GC-MS
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We analysed breath and inhaled room air samples from 39 healthy volunteers (28 non-smokers, 8 smokers and 3 ex-smokers) by SPME-GC-MS. Mixed expiratory and indoor air samples were collected in freshly cleaned Tedlar bags. Eighteen millilitres of each sample were transferred into sealed, evacuated glass vials, preconcentrated by solid-phase microextraction (SPME, carboxen/polydimethylsiloxane) and investigated by gas chromatography with mass spectrometric detection (GC-MS). For the unequivocal identification of potential marker compounds, pure calibration mixtures of reference compounds (depending on commercial availability) were prepared to determine the retention time and mass spectra with respect to our analytical setting. Applying the adapted SPME-GC/MS method with limit of detection in the high ppb range (0.05-15.00 ppb), we succeeded in identifying altogether 38 compounds with concentrations in exhaled breath being at least 50% higher than concentration in inhaled air. From these 38 compounds, 31 were identified not only by the spectral library match but also by retention time of standards. A comparison of retention times and spectrum obtained for standards and determined compounds was performed. We found hydrocarbons (isoprene, 2-pentene, 2-methyl-1-pentene, benzene, toluene, p-cymene, limonene, 2,4-dimethylheptane, n-butane), ketones (acetone, hydroxypropanone, methylvinyl ketone), ethers (dimethyl ether, 1,3-dioxolane), esters (ethyl acetate), aldehydes (propanal, hexanal, heptanal, acrolein) and alcohols (ethanol, 2-metoxyethanol, isopropyl alcohol, 2,2,3,3- tetramethylcyclopropanemethanol, 3,4-dimethylcyclohexanol). Proper identification of compounds in different cohorts of patients and volunteers is the base for further investigation of origin, biochemical background and distribution of potential breath biomarkers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High nitric oxide production in human paranasal sinuses
Lundberg, J. O. N., Farkas-Szallasi, T., Weitzberg, E., Rinder, J., Lidholm, J., Änggåard, A., Hökfelt, T., Lundberg, J. M., & Alving, K. (1995) · Nature Medicine · doi:10.1038/nm0495-370 · Cited by 628
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationAmann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationPeng, G., Hakim, M., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., Tisch, U., & Haick, H. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605810 · Cited by 775
Noninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Self-citationLi, G., Cheng, Z., Xiang, Q., Yan, L., Wang, X., & Xu, J. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.09.117 · Cited by 422
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Chen, Y., Zhang, Y., Pan, F., Liu, J., Wang, K., Zhang, C., Cheng, S., Lu, L., Zhang, W., Zhang, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b01441 · Cited by 298
Drabińska, N., Flynn, C., Ratcliffe, N., Belluomo, I., Myridakis, A., Gould, O., Fois, M., Smart, A., Devine, T., & Costello, B. D. L. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abf1d0 · Cited by 288
Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M., Liu, C.-P., & Mwakikunga, B. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 287
Isoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
Self-citationLigor, M., Ligor, T., Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Denz, H., Fiegl, M., Hilbe, W., Weiss, W., et al. (2009) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2009.133 · Cited by 262
Self-citationBuszewski, B., Ligor, T., Jezierski, T., Wenda-Piesik, A., Walczak, M., & Rudnicka, J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6102-8 · Cited by 234
Self-citationHunt, K. E., Moore, M. J., Rolland, R. M., Kellar, N. M., Hall, A. J., Kershaw, J., Raverty, S. A., Davis, C. E., Yeates, L. C., Fauquier, D. A., et al. (2013) · Conservation Physiology · doi:10.1093/conphys/cot006 · Cited by 231
“, 2006; Davidsson and Schmekel, 2010), and volatile compounds can be collected with vacuum canisters (Lindstrom and Pleil, 2002) or sorbent traps (Phillips, 1997; Ligor et al., 2008; Mieth et al., 2009; Bojko et al., 2011).”
BackgroundCurrent Challenges in Volatile Organic Compounds Analysis as Potential Biomarkers of Cancer
Schmidt, K., & Podmore, I. (2015) · Journal of Biomarkers · doi:10.1155/2015/981458 · Cited by 208
“Sorbent traps may employ additional preconcentration, such as using higher volumes of the trapping material to enhance sensitivity [117].”
BackgroundInfluentialPhysiological modeling of isoprene dynamics in exhaled breath
King, J., Koc, H., Unterkofler, K., Mochalski, P., Kupferthaler, A., Teschl, G., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2010.09.028 · Cited by 191
“Furthermore, it can relatively easily be quantified using a variety of methodologically distinct analytical techniques (Kushch et al., 2008; Ligor et al., 2008; Miekisch and Schubert, 2006; Turner et al., 2006; King et al., 2010a).”
BackgroundSelf-citationBlood and breath levels of selected volatile organic compounds in healthy volunteers
Mochalski, P., King, J., Klieber, M., Unterkofler, K., Hinterhuber, H., Baumann, M., & Amann, A. (2013) · The Analyst · doi:10.1039/c3an36756h · Cited by 190
Self-citationKing, J., Mochalski, P., Kupferthaler, A., Unterkofler, K., Koc, H., Filipiak, W., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/008 · Cited by 189
“…mass spectrometry (GC-MS) coupled with solid phase micro-extraction (SPME) as a pre-concentration method can be regarded as gold standard within this framework (Amorim and de 2007, Bajtarevic et al 2009, Ligor et al 2008, 2009, Pawliszyn 1997, Schubert et al 2003, 2005, Miekisch et al 2008).”
MethodSelf-citationMass spectrometry for real-time quantitative breath analysis
Smith, D., Španěl, P., Herbig, J., & Beauchamp, J. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027101 · Cited by 174
Schwarz, K., Pizzini, A., Arendacká, B., Zerlauth, K., Filipiak, W., Schmid, A., Dzien, A., Neuner, S., Lechleitner, M., Scholl-Bürgi, S., et al. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027003 · Cited by 164
Self-citationLung cancer biomarkers in exhaled breath
Amann, A., Corradi, M., Mazzone, P., & Mutti, A. (2011) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.10.112 · Cited by 163
Self-citationDetermining concentration patterns of volatile compounds in exhaled breath by PTR-MS
Schwarz, K., Filipiak, W., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027002 · Cited by 158
Self-citationHuman body-odor components and their determination
Pandey, S. K., & Kim, K.-H. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.12.005 · Cited by 121
Metadata
- Authors
- Ligor, T., Ligor, M., Amann, A., Ager, C., Bachler, M., Dzien, A., & Buszewski, B.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2008-10-15
- Volume
- 2
- Issue
- 4
- Pages
- 046006
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W1993125867
- Cited by
- 149
- References
- 1
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.