On-line breath analysis with PTR-TOF
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
We report on on-line breath gas analysis with a new type of analytical instrument, which represents the next generation of proton-transfer-reaction mass spectrometers. This time-of-flight mass spectrometer in combination with the soft proton-transfer-reaction ionization (PTR-TOF) offers numerous advantages for the sensitive detection of volatile organic compounds and overcomes several limitations. First, a time-of-flight instrument allows for a measurement of a complete mass spectrum within a fraction of a second. Second, a high mass resolving power enables the separation of isobaric molecules and the identification of their chemical composition. We present the first on-line breath measurements with a PTR-TOF and demonstrate the advantages for on-line breath analysis. In combination with buffered end-tidal (BET) sampling, we obtain a complete mass spectrum up to 320 Th within one exhalation with a signal-to-noise ratio sufficient to measure down to pptv levels. We exploit the high mass resolving power to identify the main components in the breath composition of several healthy volunteers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Self-citationDiagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Human exhaled air analytics: biomarkers of diseases
Buszewski, B., Kęsy, M., Ligor, T., & Amann, A. (2007) · Biomedical Chromatography · doi:10.1002/bmc.835 · Cited by 792
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
Self-citationDetection of Lung Cancer With Volatile Markers in the Breatha
Phillips, M., Cataneo, R. N., Cummin, A. R. C., Gagliardi, A. J., Gleeson, K., Greenberg, J., Maxfield, R. A., & Rom, W. N. (2003) · Chest · doi:10.1378/chest.123.6.2115 · Cited by 567
Method for the Collection and Assay of Volatile Organic Compounds in Breath
Phillips, M. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2069 · Cited by 367
Current status of clinical breath analysis
Risby, T. H., & Solga, S. F. (2006) · Applied Physics B · doi:10.1007/s00340-006-2280-4 · Cited by 363
de Gouw, J., Warneke, C., Karl, T., Eerdekens, G., van der Veen, C., & Fall, R. (2003) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00926-0 · Cited by 345
Warneke, C., de Gouw, J. A., Kuster, W. C., Goldan, P. D., & Fall, R. (2003) · Environmental Science & Technology · doi:10.1021/es026266i · Cited by 288
Lung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas
Wehinger, A., Schmid, A., Mechtcheriakov, S., Ledochowski, M., Grabmer, C., Gastl, G. A., & Amann, A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.05.012 · Cited by 280
Buhr, K., van Ruth, S., & Delahunty, C. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00896-5 · Cited by 271
On the use of Tedlar® bags for breath-gas sampling and analysis
Beauchamp, J., Herbig, J., Gutmann, R., & Hansel, A. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/4/046001 · Cited by 236
Self-citationDetection of human metabolites using multi-capillary columns coupled to ion mobility spectrometers
Ruzsanyi, V., Baumbach, J. I., Sielemann, S., Litterst, P., Westhoff, M., & Freitag, L. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.01.055 · Cited by 206
Breath analysis: trends in techniques and clinical applications
Di Francesco, F., Fuoco, R., Trivella, M. G., & Ceccarini, A. (2005) · Microchemical Journal · doi:10.1016/j.microc.2004.10.008 · Cited by 206
Blake, R. S., Whyte, C., Hughes, C. O., et al. (2004) · Analytical Chemistry · doi:10.1021/ac0498260 · Cited by 205
Preti, G., Labows, J. N., Kostelc, J. G., Aldinger, S., & Daniele, R. (1988) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)80627-1 · Cited by 196
Mass spectrometric profile of exhaled breath—field study by PTR-MS
Moser, B., Bodrogi, F., Eibl, G., Lechner, M., Rieder, J., & Lirk, P. (2005) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2004.02.002 · Cited by 180
The suitability of Tedlar bags for breath sampling in medical diagnostic research
Steeghs, M. M. L., Cristescu, S. M., & Harren, F. J. M. (2006) · Physiological Measurement · doi:10.1088/0967-3334/28/1/007 · Cited by 126
Pabst, F., Miekisch, W., Fuchs, P., Kischkel, S., & Schubert, J. K. (2007) · Journal of Cardiothoracic Surgery · doi:10.1186/1749-8090-2-37 · Cited by 100
Buffered end-tidal (BET) sampling—a novel method for real-time breath-gas analysis
Herbig, J., Titzmann, T., Beauchamp, J. D., Kohl, I., & Hansel, A. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037008 · Cited by 97
Self-citationTanimoto, H., Aoki, N., Inomata, S., Hirokawa, J., & Sadanaga, Y. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.01.009 · Cited by 72
Odor Concentration Decay and Stability in Gas Sampling Bags
van Harreveld, A. P. (2003) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2003.10466121 · Cited by 70
Dryahina, K., Smith, D. C., & Španěl, P. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4513 · Cited by 57
Jones, A. W., Beylich, K. M., Bjørneboe, A., Ingum, J., & Mørland, J. G. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.5.743 · Cited by 53
Suitability of different plastic materials for head or nose spaces short term storage
Pet’ka, J., Étiévant, P. X., & Callement, G. (2000) · Analusis · doi:10.1051/analusis:2000123 · Cited by 31
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
“Only a few volatile compounds in exhaled breath have been investigated in real-time measurements by PTR-MS [71–73], PTR-TOF-MS [74, 75], SIFT-MS [76–79], laser spectrometry or sensors [80–84]: among them are isoprene, acetone, 2-pentanone, dimethylsulfide, methyl acetate [67], eucalyptol [85], hydrogen, methane [21, 8…”
MethodAmann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
Metadata
- Authors
- Herbig, J., Müller, M., Schallhart, S., Titzmann, T., Graus, M., & Hansel, A.
- Venue
- Journal of Breath Research
- Publisher
- IOP Publishing
- Published
- 2009-06-01
- Volume
- 3
- Issue
- 2
- Pages
- 027004
- ISSN
- 1752-7155 (ISSN-L)
- 1752-7163
- OpenAlex
- W2131674846
- Cited by
- 205
- References
- 27
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.