CoChat

Silicone-based adhesives for long-term skin application: cleaning protocols and their effect on peel strength

Open access
Liu, Li, Kuffel, Kristina, Scott, Dylan K, Constantinescu, Gabriela, Chung, Hyun-Joong, Rieger, Jana · 2017 · Biomedical Physics & Engineering Express
Cited by 41

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Adhesives that involve adhesion to the skin have been of great technological importance in medical or pharmaceutical fields, including recently emerging wearable sensors and electronics. The objective of this work was to evaluate the performances of silicone-based adhesives with skin, using a peel adhesion test. Specifically, we explored the effect of adhesive cleansing, which is an inevitable daily event for patients' comfort in long-term applications. Firstly, three medical grade silicone gels, Silbione® RT 4717, Silbione® RT 4642, and Silpuran® 2130, were used to fabricate adhesive pads. Their peel strength values were subsequently measured and compared, among which Silbione® RT gel 4717 possessed the highest peel strength. Therefore, it was selected as the raw material to fabricate the pads with a thickness range of 640–740 μ m. Secondly, the peel adhesion of Silbione® RT 4717 adhesive pad was further compared with a series of commercial products that employ various medical-grade adhesives. The peel strength results indicated that our custom-made adhesive pad had an adequately strong adhesion for clinical use. Thirdly, in order to observe and predict the long-term performance of the adhesives, an aging test was performed in an ambient environment, revealing that Silbione® RT 4717 adhesive remained highly sticky for 5 days. Lastly, adequate cleansing protocols were established by monitoring the changes in peel strength after washing and wiping events. The reusability analysis showed that Silbione® 4717 adhesive pad was reusable in a one-week period for the washing method and 3 days for the wiping method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/2057-1976/aa91fb

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 41

Metadata

Authors
Liu, L., Kuffel, K., Scott, D. K., Constantinescu, G., Chung, H.-J., & Rieger, J.
Venue
Biomedical Physics & Engineering Express
Published
2017-11-27
Volume
4
Issue
1
Pages
015004
ISSN
2057-1976 (ISSN-L)
OpenAlex
W2762765187
Cited by
41
References
4
FWCI
2.17
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Silicone-based adhesives for long-term skin application: cleaning protocols and their effect on peel strength. https://app.cochat.ai/papers/10.1088/2057-1976/aa91fb
The paper
Liu, L., Kuffel, K., Scott, D. K., Constantinescu, G., Chung, H.-J., & Rieger, J. (2017). Silicone-based adhesives for long-term skin application: cleaning protocols and their effect on peel strength. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/aa91fb

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.