Translational prospects of untethered medical microrobots
Open accessThe DOI matches its Crossref record; 163 of the 163 references it cites were found in a registry or an index.
Abstract
Untethered mobile microrobots have the potential to transform medicine radically. Their small size and wireless mobility can enable access to and navigation in confined, small, hard-to-reach, and sensitive inner body sites, where they can provide new ways of minimally invasive interventions and targeted diagnosis and therapy down to the cellular length scales with high precision and repeatability. The exponential recent progress of the field at the preclinical level raises anticipations for their near-future clinical prospects. To pave the way for this transformation to happen, however, the formerly proposed microrobotic system designs need a comprehensive review by including essential aspects that a microrobot needs to function properly and safely in given in vivo conditions of a targeted medical problem. The present review provides a translational perspective on medical microrobotics research with an application-oriented, integrative design approach. The blueprint of a medical microrobot needs to take account of microrobot shape, material composition, manufacturing technique, permeation of biological barriers, deployment strategy, actuation and control methods, medical imaging modality, and the execution of the prescribed medical tasks altogether at the same time. The incorporation of functional information pertaining each such element to the physical design of the microrobot is highly dependent on the specific clinical application scenario. We discuss the complexity of the challenges ahead and the potential directions to overcome them. We also throw light on the potential regulatory aspects of medical microrobots toward their bench-to-bedside translation. Such a multifaceted undertaking entails multidisciplinary involvement of engineers, materials scientists, biologists and medical doctors, and bringing their focus on specific medical problems where microrobots could make a disruptive or radical impact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding biophysicochemical interactions at the nano–bio interface
Nel, A. E., Mädler, L., Velegol, D., Xia, T., Hoek, E. M. V., Somasundaran, P., Klaessig, F., Castranova, V., & Thompson, M. (2009) · Nature Materials · doi:10.1038/nmat2442 · Cited by 7,083 · cited 2×
“When a microrobot is inside the body, a myriad of proteins will interact with its surface that will spontaneously form an adsorption layer around, called protein corona (figure 2(A)) [71, 72].”
BackgroundPurcell, E. M. (1977) · American Journal of Physics · doi:10.1119/1.10903 · Cited by 4,360 · cited 1×
“non-reciprocal, shape changes with its body [132, 177].”
Opsonization, biodistribution, and pharmacokinetics of polymeric nanoparticles
OWENSIII, D., & PEPPAS, N. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2005.10.010 · Cited by 3,637
Regulation of transport pathways in tumor vessels: Role of tumor type and microenvironment
Hobbs, S. K., Monsky, W. L., Yuan, F., Roberts, W. G., Griffith, L., Torchilin, V. P., & Jain, R. K. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4607 · Cited by 2,438
Small-scale soft-bodied robot with multimodal locomotion
Hu, W., Lum, G. Z., Mastrangeli, M., & Sitti, M. (2018) · Nature · doi:10.1038/nature25443 · Cited by 2,372 · cited 5×
“7 mm and a gripper with the diameter of 4 mm were successfully visualized via ultrasonographic investigation (figure 5(B)) [139, 172].”
BackgroundMethodInfluentialSelf-citationRapid formation of plasma protein corona critically affects nanoparticle pathophysiology
Tenzer, S., Docter, D., Kuharev, J., Musyanovych, A., Fetz, V., Hecht, R., Schlenk, F., Fischer, D., Kiouptsi, K., Reinhardt, C., et al. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.181 · Cited by 2,283 · cited 1×
“When a microrobot is inside the body, a myriad of proteins will interact with its surface that will spontaneously form an adsorption layer around, called protein corona (figure 2(A)) [71, 72].”
BackgroundBiomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206 · cited 1×
“Materials that predictably decompose and disappear over time as a result of the resident biological activity have become increasingly important for medical applications [186].”
BackgroundHyperthermia in combined treatment of cancer
Wust, P., Hildebrandt, B., Sreenivasa, G., Rau, B., Gellermann, J., Riess, H., Felix, R., & Schlag, P. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00818-5 · Cited by 1,998
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968 · cited 1×
“Following the collection of the specimen, robots must follow the shortest possible path to bring the specimen back with no contamination for evaluation ex vivo, or be equipped with remote sensing for carrying out in vivo diagnostic or prognostic tests [5].”
Background(2010) · Cited by 1,697
Cited by
Wang, B., Kostarelos, K., Nelson, B. J., & Zhang, L. (2021) · Advanced Materials · doi:10.1002/adma.202002047 · Cited by 497
Engineering microrobots for targeted cancer therapies from a medical perspective
Schmidt, C. K., Medina-Sánchez, M., Edmondson, R. J., & Schmidt, O. G. (2020) · Nature Communications · doi:10.1038/s41467-020-19322-7 · Cited by 441
Smart Materials for Microrobots
Soto, F., Karshalev, E., Zhang, F., Esteban Fernandez de Avila, B., Nourhani, A., & Wang, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00999 · Cited by 433
Multifunctional surface microrollers for targeted cargo delivery in physiological blood flow
Alapan, Y., Bozuyuk, U., Erkoc, P., Karacakol, A. C., & Sitti, M. (2020) · Science Robotics · doi:10.1126/scirobotics.aba5726 · Cited by 414
Self-citationPros and Cons: Magnetic versus Optical Microrobots
Sitti, M., & Wiersma, D. S. (2020) · Advanced Materials · doi:10.1002/adma.201906766 · Cited by 398
Self-citationBiomedical Micro‐/Nanomotors: From Overcoming Biological Barriers to In Vivo Imaging
Gao, C., Wang, Y., Ye, Z., Lin, Z., Ma, X., & He, Q. (2021) · Advanced Materials · doi:10.1002/adma.202000512 · Cited by 358
Wang, Q., Chan, K. F., Schweizer, K., Du, X., Jin, D., Yu, S. C. H., Nelson, B. J., & Zhang, L. (2021) · Science Advances · doi:10.1126/sciadv.abe5914 · Cited by 348
3D printing of functional microrobots
Li, J., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01062f · Cited by 303
Photoacoustic Imaging-Trackable Magnetic Microswimmers for Pathogenic Bacterial Infection Treatment
Xie, L., Pang, X., Yan, X., Dai, Q., Lin, H., Ye, J., Cheng, Y., Zhao, Q., Ma, X., Zhang, X., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b06731 · Cited by 261
Ferromagnetic soft catheter robots for minimally invasive bioprinting
Zhou, C., Yang, Y., Wang, J., Wu, Q., Gu, Z., Zhou, Y., Liu, X., Yang, Y., Tang, H., Ling, Q., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25386-w · Cited by 242
External Power-Driven Microrobotic Swarm: From Fundamental Understanding to Imaging-Guided Delivery
Wang, Q., & Zhang, L. (2021) · ACS Nano · doi:10.1021/acsnano.0c07753 · Cited by 231
Biodegradable Untethered Magnetic Hydrogel Milli‐Grippers
Goudu, S. R., Yasa, I. C., Hu, X., Ceylan, H., Hu, W., & Sitti, M. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004975 · Cited by 207
Self-citationMicro/nanoscale magnetic robots for biomedical applications
Koleoso, M., Feng, X., Xue, Y., Li, Q., Munshi, T., & Chen, X. (2020) · Materials Today Bio · doi:10.1016/j.mtbio.2020.100085 · Cited by 174
Zwitterionic 3D‐Printed Non‐Immunogenic Stealth Microrobots
Cabanach, P., Pena‐Francesch, A., Sheehan, D., Bozuyuk, U., Yasa, O., Borros, S., & Sitti, M. (2020) · Advanced Materials · doi:10.1002/adma.202003013 · Cited by 171
Self-citationMicro-rocket robot with all-optic actuating and tracking in blood
Li, D., Liu, C., Yang, Y., Wang, L., & Shen, Y. (2020) · Light: Science & Applications · doi:10.1038/s41377-020-0323-y · Cited by 170
Metadata
- Authors
- Ceylan, H., Yasa, I. C., Kilic, U., Hu, W., & Sitti, M.
- Venue
- Progress in Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 2019-07-01
- Volume
- 1
- Issue
- 1
- Pages
- 012002
- ISSN
- 2516-1091 (ISSN-L)
- OpenAlex
- W2958330632
- Cited by
- 188
- References
- 163
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.