Toward Tissue Engineering of the Knee Meniscus
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
This review details current efforts to tissue engineer the knee meniscus successfully. The meniscus is a fibrocartilaginous tissue found within the knee joint that is responsible for shock absorption, load transmission, and stability within the knee joint. If this tissue is damaged, either through tears or degenerative processes, then deterioration of the articular cartilage can occur. Unfortunately, there is a dearth in the amount of work done to tissue engineer the meniscus when compared to other musculoskeletal tissues, such as bone. This review gives a brief overview of meniscal anatomy, biochemical properties, biomechanical properties, and wound repair techniques. The discussion centers primarily on the different components of attempting to tissue engineer the meniscus, such as scaffold materials, growth factors, animal models, and culturing conditions. Our approach for tissue engineering the meniscus is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microvasculature of the human meniscus
Arnoczky, S. P., & Warren, R. F. (1982) · The American Journal of Sports Medicine · doi:10.1177/036354658201000205 · Cited by 1,239
The Role of the Menisci in Force Transmission Across the Knee
Walker, P. S., & Erkiuan, M. J. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197506000-00027 · Cited by 1,117 · cited 2×
“8 If the meniscus is cut or removed, then the pressure seen by the tibial plate increases.”
Material Properties and Structure-Function Relationships in the Menisci
FITHIAN, D. C., KELLY, M. A., & MOW, V. C. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199003000-00004 · Cited by 777 · cited 7×
“57,61 It has been shown that shear properties are anisotropic, with the stiffness being the lowest in the planes that run parallel to the major collagen orientation.”
InfluentialSHIINA, S., AOYAMA, H., SHIRATORI, Y., MUTOH, H., KURITA, M., OTA, S., TERANO, A., & SUGIMOTO, T. (1990) · INVESTIGATIVE RADIOLOGY · doi:10.1097/00004424-199006000-00006 · Cited by 654
MESSNER, K., & GAO, J. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19320161.x · Cited by 431 · cited 1×
“16 –122 In general, the data from these tests are useful for comparing data between different sections of the meniscus, but not for cross-species tests.”
Collagenous fibril texture of the human knee joint menisci
Petersen, W., & Tillmann, B. (1998) · Anatomy and Embryology · doi:10.1007/s004290050141 · Cited by 427
The Degenerative Effects of Partial and Total Resection of the Medial Meniscus in Dogs?? Knees
Cox, J. S., Nye, C. E., Schaefer, W. W., & Woodstein, I. J. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197506000-00026 · Cited by 409 · cited 2×
“69 After a partial meniscectomy, a fibrin clot forms in the area of the removed tissue, which then acts as a scaffold for cellular ingrowth, though this does not always occur.”
Material properties of the normal medial bovine meniscus
Proctor, C. S., Schmidt, M. B., Whipple, R. R., Kelly, M. A., & Mow, V. C. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070602 · Cited by 383 · cited 6×
“29,51,52 The ovine model is an excellent model because certain mechanical properties closely match that of human tissue.”
InfluentialAthanasiou, K. A., Agarwal, A., & Dzida, F. J. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120306 · Cited by 343 · cited 1×
“59,60 to find the aggregate modulus ( H A ), permeability ( k ), and Poisson’s ratio ( v s ) at different locations of the human meniscus; the results are shown in Table 2.”
Self-citationChemical changes of human knee joint menisci in various stages of degeneration.
Herwig, J., Egner, E., & Buddecke, E. (1984) · Annals of the Rheumatic Diseases · doi:10.1136/ard.43.4.635 · Cited by 297
Cited by
Makris, E. A., Hadidi, P., & Athanasiou, K. A. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.037 · Cited by 1,116
Self-citationGiordano, A., Galderisi, U., & Marino, I. R. (2007) · Journal of Cellular Physiology · doi:10.1002/jcp.20959 · Cited by 609
How smart do biomaterials need to be? A translational science and clinical point of view
Holzapfel, B. M., Reichert, J. C., Schantz, J.-T., Gbureck, U., Rackwitz, L., Nöth, U., Jakob, F., Rudert, M., Groll, J., & Hutmacher, D. W. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.009 · Cited by 552
Yang, Y., Chen, Z., Song, X., Zhang, Z., Zhang, J., Shung, K. K., Zhou, Q., & Chen, Y. (2017) · Advanced Materials · doi:10.1002/adma.201605750 · Cited by 316
Engineering Orthopedic Tissue Interfaces
Yang, P. J., & Temenoff, J. S. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0371 · Cited by 294
Tissue engineering of the meniscus
Buma, P., Ramrattan, N. N., van Tienen, T. G., & Veth, R. P. H. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00499-x · Cited by 253
Design Characteristics for the Tissue Engineering of Cartilaginous Tissues
Almarza, A. J., & Athanasiou, K. A. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000007786.37957.65 · Cited by 226
Self-citationBacterial cellulose as a potential meniscus implant
Bodin, A., Concaro, S., Brittberg, M., & Gatenholm, P. (2007) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.51 · Cited by 208
“Pig meniscus was harvested from pigs (34 kg), kept in PBS buffer, quenched in liquid nitrogen and kept frozen until measurement, as reported by Sweigart and Athanasiou (2001).”
MethodMultilayered silk scaffolds for meniscus tissue engineering
Mandal, B. B., Park, S.-H., Gil, E. S., & Kaplan, D. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.115 · Cited by 193
“We hypothesized that this will aid aligning deposited collagen and other ECM in a laminar morphology similar to that of the native meniscus, mimicking the aligned collagen bundles contributing to high intrinsic tensile and compressive properties [14,28,29].”
InfluentialCell delivery therapeutics for musculoskeletal regeneration☆
Nöth, U., Rackwitz, L., Steinert, A. F., & Tuan, R. S. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.04.004 · Cited by 119
Metadata
- Authors
- Sweigart, M. A., & Athanasiou, K. A.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2001-04
- Volume
- 7
- Issue
- 2
- Pages
- 111-129
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2057575379
- Cited by
- 215
- References
- 48
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.