Two-Dimensional Manipulation of Cardiac Myocyte Sheets Utilizing Temperature-Responsive Culture Dishes Augments the Pulsatile Amplitude
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Although cardiac myocytes adherent to tissue culture polystyrene (TCPS) dishes retain the spontaneous beating, the pulsatile amplitude is highly limited compared to that in vivo. One of the main reasons for the limited pulsation may be the interface between the cells and the TCPS surfaces. Release of these cells from rigid TCPS surfaces may augment their pulsatile amplitude. With this perspective, we have developed a novel cell manipulation technique to detach cultured cardiac myocytes from rigid surfaces and to rescue higher pulsatile amplitude of the cells using temperature-responsive culture dishes and discuss the possibility of improving this heart tissue model. Primary cardiac myocytes were cultured on the slightly hydrophobic dish surfaces grafted with a temperature-responsive polymer, poly(N-isopropylacrylamide). Cells adhered and proliferated, forming confluent cardiac myocyte sheets in a fashion similar to those on ungrafted TCPS dishes. Decrease in culture temperature resulted in surface change of the polymer from slight hydrophobic to highly hydrophilic due to extensive hydration of the grafted polymer on the dishes. This results in release of cardiac myocyte sheets from the dishes without enzymatic or EDTA treatment. When no support was used, the detached cardiac myocyte sheets shrank to one-tenth size, which ceased their pulsation. When chitin membranes were used to support the confluent sheets to prevent cell shrinkage, the detached cell sheets could be transferred and readily adhered onto another virgin TCPS dishes. These transferred cell sheets preserved the similar cell morphology and pulsation to those before the detachment. When polyethylene meshes were used to support cell sheet transfer, detached cardiac myocyte sheets partially attached to the mesh threads. Then, the constructs were inverted and placed in another culture dish to prevent direct association to dish surfaces. Moreover, the cardiac myocyte sheets were reorganized to heart tissue-like structures by the unisotropic contraction orientated by the mesh threads, and the pulsatile amplitude increased more than 10 times higher. This technique would bring about new insight in tissue engineering as well as cultured heart model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Embryonic Stem Cell Lines Derived from Human Blastocysts
Thomson, J. A., Itskovitz-Eldor, J., Shapiro, S. S., Waknitz, M. A., Swiergiel, J. J., Marshall, V. S., & Jones, J. M. (1998) · Science · doi:10.1126/science.282.5391.1145 · Cited by 15,926
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
Cited by
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
Shimizu, T., Yamato, M., Isoi, Y., Akutsu, T., Setomaru, T., Abe, K., Kikuchi, A., Umezu, M., & Okano, T. (2002) · Circulation Research · doi:10.1161/hh0302.105722 · Cited by 956
Self-citationLessons from nature: stimuli-responsive polymers and their biomedical applications
Jeong, B., & Gutowska, A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)01962-5 · Cited by 856
Muscular Thin Films for Building Actuators and Powering Devices
Feinberg, A. W., Feigel, A., Shevkoplyas, S. S., Sheehy, S., Whitesides, G. M., & Parker, K. K. (2007) · Science · doi:10.1126/science.1146885 · Cited by 765
Cell sheet engineering for myocardial tissue reconstruction
Shimizu, T., Yamato, M., Kikuchi, A., & Okano, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00110-8 · Cited by 673
Self-citationSmart polymeric gels: Redefining the limits of biomedical devices
Chaterji, S., Kwon, I. K., & Park, K. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.018 · Cited by 615
Kamao, H., Mandai, M., Okamoto, S., Sakai, N., Suga, A., Sugita, S., Kiryu, J., & Takahashi, M. (2014) · Stem Cell Reports · doi:10.1016/j.stemcr.2013.12.007 · Cited by 592
Akiyama, Y., Kikuchi, A., Yamato, M., & Okano, T. (2004) · Langmuir · doi:10.1021/la036139f · Cited by 551
Self-citationThermosensitive sol–gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.012 · Cited by 533
Reconstruction of functional tissues with cell sheet engineering
Yang, J., Yamato, M., Shimizu, T., Sekine, H., Ohashi, K., Kanzaki, M., Ohki, T., Nishida, K., & Okano, T. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.052 · Cited by 482
Self-citationFedorovich, N. E., Alblas, J., de Wijn, J. R., Hennink, W. E., Verbout, A. J., & Dhert, W. J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0175 · Cited by 467
Thermoresponsive polymers and their biomedical application in tissue engineering – a review
Doberenz, F., Zeng, K., Willems, C., Zhang, K., & Groth, T. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02052g · Cited by 427
Tissue Engineering Based on Cell Sheet Technology
Matsuda, N., Shimizu, T., Yamato, M., & Okano, T. (2007) · Advanced Materials · doi:10.1002/adma.200701978 · Cited by 398
Self-citationNagase, K., Yamato, M., Kanazawa, H., & Okano, T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.026 · Cited by 393
Self-citationBiomaterials in cardiac tissue engineering: Ten years of research survey
Chen, Q.-Z., Harding, S. E., Ali, N. N., Lyon, A. R., & Boccaccini, A. R. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.08.001 · Cited by 382
Contractile cardiac grafts using a novel nanofibrous mesh
Shin, M., Ishii, O., Sueda, T., & Vacanti, J. P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.055 · Cited by 359
Self-assembled microdevices driven by muscle
Xi, J., Schmidt, J. J., & Montemagno, C. D. (2005) · Nature Materials · doi:10.1038/nmat1308 · Cited by 322
da Silva, R. M. P., Mano, J. F., & Reis, R. L. (2007) · Trends in Biotechnology · doi:10.1016/j.tibtech.2007.08.014 · Cited by 310
Sekine, H., Shimizu, T., Dobashi, I., Matsuura, K., Hagiwara, N., Takahashi, M., Kobayashi, E., Yamato, M., & Okano, T. (2011) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0659 · Cited by 276
Self-citationMyocardial tissue engineering: a review
Jawad, H., Ali, N. N., Lyon, A. R., Chen, Q. Z., Harding, S. E., & Boccaccini, A. R. (2007) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.46 · Cited by 264
Kikuchi, A., & Okano, T. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.08.026 · Cited by 264
Self-citationTemperature-responsive cell culture surfaces for regenerative medicine with cell sheet engineering
Yamato, M., Akiyama, Y., Kobayashi, J., Yang, J., Kikuchi, A., & Okano, T. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.06.002 · Cited by 254
Self-citationShimizu, T., Sekine, H., Isoi, Y., Yamato, M., Kikuchi, A., & Okano, T. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.499 · Cited by 209
Self-citationBiomimetic mechanically adaptive nanocomposites
Shanmuganathan, K., Capadona, J. R., Rowan, S. J., & Weder, C. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.10.005 · Cited by 209
Stimuli-Responsive Mechanically Adaptive Polymer Nanocomposites
Shanmuganathan, K., Capadona, J. R., Rowan, S. J., & Weder, C. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am9006337 · Cited by 160
Contractile three-dimensional bioengineered heart muscle for myocardial regeneration
Huang, Y., Khait, L., & Birla, R. K. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31090 · Cited by 90
Metadata
- Authors
- Shimizu, T., Yamato, M., Kikuchi, A., & Okano, T.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2001-04
- Volume
- 7
- Issue
- 2
- Pages
- 141-151
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2040341666
- Cited by
- 247
- References
- 2
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.