Two-Dimensional Manipulation of Cardiac Myocyte Sheets Utilizing Temperature-Responsive Culture Dishes Augments the Pulsatile Amplitude
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Although cardiac myocytes adherent to tissue culture polystyrene (TCPS) dishes retain the spontaneous beating, the pulsatile amplitude is highly limited compared to that in vivo. One of the main reasons for the limited pulsation may be the interface between the cells and the TCPS surfaces. Release of these cells from rigid TCPS surfaces may augment their pulsatile amplitude. With this perspective, we have developed a novel cell manipulation technique to detach cultured cardiac myocytes from rigid surfaces and to rescue higher pulsatile amplitude of the cells using temperature-responsive culture dishes and discuss the possibility of improving this heart tissue model. Primary cardiac myocytes were cultured on the slightly hydrophobic dish surfaces grafted with a temperature-responsive polymer, poly(N-isopropylacrylamide). Cells adhered and proliferated, forming confluent cardiac myocyte sheets in a fashion similar to those on ungrafted TCPS dishes. Decrease in culture temperature resulted in surface change of the polymer from slight hydrophobic to highly hydrophilic due to extensive hydration of the grafted polymer on the dishes. This results in release of cardiac myocyte sheets from the dishes without enzymatic or EDTA treatment. When no support was used, the detached cardiac myocyte sheets shrank to one-tenth size, which ceased their pulsation. When chitin membranes were used to support the confluent sheets to prevent cell shrinkage, the detached cell sheets could be transferred and readily adhered onto another virgin TCPS dishes. These transferred cell sheets preserved the similar cell morphology and pulsation to those before the detachment. When polyethylene meshes were used to support cell sheet transfer, detached cardiac myocyte sheets partially attached to the mesh threads. Then, the constructs were inverted and placed in another culture dish to prevent direct association to dish surfaces. Moreover, the cardiac myocyte sheets were reorganized to heart tissue-like structures by the unisotropic contraction orientated by the mesh threads, and the pulsatile amplitude increased more than 10 times higher. This technique would bring about new insight in tissue engineering as well as cultured heart model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Embryonic Stem Cell Lines Derived from Human Blastocysts
Thomson, J. A., Itskovitz-Eldor, J., Shapiro, S. S., Waknitz, M. A., Swiergiel, J. J., Marshall, V. S., & Jones, J. M. (1998) · Science · doi:10.1126/science.282.5391.1145 · Cited by 15,926
Solution Properties of Poly(N-isopropylacrylamide)
Heskins, M., & Guillet, J. E. (1968) · Journal of Macromolecular Science: Part A - Chemistry · doi:10.1080/10601326808051910 · Cited by 3,117
Doetschman, T. C., Eistetter, H., Katz, M., Schmidt, W., & Kemler, R. (1985) · Development · doi:10.1242/dev.87.1.27 · Cited by 1,962
Cardiomyocytes can be generated from marrow stromal cells in vitro
Makino, S., Fukuda, K., Miyoshi, S., Konishi, F., Kodama, H., Pan, J., Sano, M., Takahashi, T., Hori, S., Abe, H., et al. (1999) · Journal of Clinical Investigation · doi:10.1172/jci5298 · Cited by 1,884 · cited 1×
“8 Although primary culture of cardiac myocytes show spontaneous pulsatile beating, the pulsatile amplitude is highly limited compared to that in vivo and insufficient for clinical use.”
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
Derivation of pluripotent stem cells from cultured human primordial germ cells
Shamblott, M. J., Axelman, J., Wang, S., Bugg, E. M., Littlefield, J. W., Donovan, P. J., Blumenthal, P. D., Huggins, G. R., & Gearhart, J. D. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.23.13726 · Cited by 1,420
Okano, T., Yamada, N., Sakai, H., & Sakurai, Y. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271005 · Cited by 1,020 · cited 1×
“12 We have also created designed cell sheets using the dishes grafted in various patterns and developed a two-dimensional cell sheet manipulation technique to transfer cell sheets from temperature-responsive surfaces to other supports.”
Self-citationThermo‐responsive polymeric surfaces; control of attachment and detachment of cultured cells
Yamada, N., Okano, T., Sakai, H., Karikusa, F., Sawasaki, Y., & Sakurai, Y. (1990) · Die Makromolekulare Chemie, Rapid Communications · doi:10.1002/marc.1990.030111109 · Cited by 983 · cited 2×
“11 This surface is slightly hydrophobic under culture conditions at 37°C, and changes to be hydrophilic below the lower critical solution temperature (LCST) near 32°C.”
Self-citationMechanism of cell detachment from temperature-modulated, hydrophilic-hydrophobic polymer surfaces
Okano, T., Yamada, N., Okuhara, M., Sakai, H., & Sakurai, Y. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93257-e · Cited by 886 · cited 2×
“13,16 Here, we have examined whether the same mechanisms contribute to cardiac myocyte sheet detachment.”
Self-citationLessons from nature: stimuli-responsive polymers and their biomedical applications
Jeong, B., & Gutowska, A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)01962-5 · Cited by 856
Temperature dependence of swelling of crosslinked poly(N,N′‐alkyl substituted acrylamides) in water
Bae, Y. H., Okano, T., & Kim, S. W. (1990) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.1990.090280609 · Cited by 578
Self-citationKushida, A., Yamato, M., Konno, C., Kikuchi, A., Sakurai, Y., & Okano, T. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990615)45:4<355::aid-jbm10>3.0.co;2-7 · Cited by 493
Self-citationRapid cell sheet detachment from Poly(N-isopropylacrylamide)-grafted porous cell culture membranes
Kwon, O. H., Kikuchi, A., Yamato, M., Sakurai, Y., & Okano, T. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200004)50:1<82::aid-jbm12>3.0.co;2-7 · Cited by 266
Self-citationHirose, M., Kwon, O. H., Yamato, M., Kikuchi, A., & Okano, T. (2000) · Biomacromolecules · doi:10.1021/bm0002961 · Cited by 243 · cited 1×
“19,20 This technique might prove useful for preparation of sophisticated implantable constructs utilizable in tissue engineering.”
Self-citationShimizu, T., Yamato, M., Akutsu, T., Shibata, T., Isoi, Y., Kikuchi, A., Umezu, M., & Okano, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1284 · Cited by 202
Self-citationYamato, M., Okuhara, M., Karikusa, F., Kikuchi, A., Sakurai, Y., & Okano, T. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199901)44:1<44::aid-jbm5>3.0.co;2-x · Cited by 168
Self-citationMechanical Circulatory Support and Cardiac Transplantation
Hunt, S. A., & Frazier, O. H. (1998) · Circulation · doi:10.1161/01.cir.97.20.2079 · Cited by 156
Cardiomyocyte Transplantation in a Porcine Myocardial Infarction Model
Watanabe, E. (1998) · Cell Transplantation · doi:10.1016/s0963-6897(98)00011-6 · Cited by 129
Novel thermally reversible hydrogel as detachable cell culture substrate
von Recum, H. A., Kim, S. W., Kikuchi, A., Okuhara, M., Sakurai, Y., & Okano, T. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980615)40:4<631::aid-jbm15>3.0.co;2-i · Cited by 118
Self-citationNandkumar, M. A., Yamato, M., Kushida, A., Konno, C., Hirose, M., Kikuchi, A., & Okano, T. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00225-3 · Cited by 101
Self-citationRetinal pigmented epithelium cultures on thermally responsive polymer porous substrates
von Recum, H. A., Kikuchi, A., Okuhara, M., Sakurai, Y., Okano, T., & Kim, S. W. (1998) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856298x00758 · Cited by 56
Self-citationLocalization and distribution of gap junctions in normal and cardiomyopathic hamster heart
Luque, E. A., Veenstra, R. D., Beyer, E. C., & Lemanski, L. F. (1994) · Journal of Morphology · doi:10.1002/jmor.1052220207 · Cited by 35 · cited 1×
“23 Therefore, gap junctions play a crucial role in electrically synchronous beating of the tissue and the whole organ.”
Platelet-derived growth factor induces cellular growth in cultured chick ventricular myocytes
Shimizu, T., Kinugawa, K., Yao, A., Sugishita, Y., Sugishita, K., Harada, K., Matsui, H., Kohmoto, O., Serizawa, T., & Takahashi, T. (1999) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00261-2 · Cited by 21 · cited 1×
“22 The cells obtained by trypsinization from ventricles of chick embryos at Humburger and Hamilton stage 36 were suspended in the culture medium consisting of 6% fetal bovine serum (FBS), 40% Medium 199, 0.2% peni-cillin-streptomycin solution, 2.7 mM glucose, and 54% balanced salt solution…”
InfluentialSelf-citationMilano, C. A., Allen, L. F., Dolber, P. C., Johnson, T. D., Rockman, H. A., Bond, R. A., & Lefkowitz, R. J. (1995) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(95)70384-5 · Cited by 20
Cited by
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
Shimizu, T., Yamato, M., Isoi, Y., Akutsu, T., Setomaru, T., Abe, K., Kikuchi, A., Umezu, M., & Okano, T. (2002) · Circulation Research · doi:10.1161/hh0302.105722 · Cited by 956
Self-citationLessons from nature: stimuli-responsive polymers and their biomedical applications
Jeong, B., & Gutowska, A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)01962-5 · Cited by 856
Muscular Thin Films for Building Actuators and Powering Devices
Feinberg, A. W., Feigel, A., Shevkoplyas, S. S., Sheehy, S., Whitesides, G. M., & Parker, K. K. (2007) · Science · doi:10.1126/science.1146885 · Cited by 765
Cell sheet engineering for myocardial tissue reconstruction
Shimizu, T., Yamato, M., Kikuchi, A., & Okano, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00110-8 · Cited by 673
Self-citation
Metadata
- Authors
- Shimizu, T., Yamato, M., Kikuchi, A., & Okano, T.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2001-04
- Volume
- 7
- Issue
- 2
- Pages
- 141-151
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2040341666
- Cited by
- 247
- References
- 24
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.