Micropatterned Schwann Cell–Seeded Biodegradable Polymer Substrates Significantly Enhance Neurite Alignment and Outgrowth
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Biomimetic strategies were employed to promote directional outgrowth of neurites in vitro by using a synergistic combination of physical, chemical, and cellular cues. Compression molded and solvent cast biodegradable polymer substrates made of poly(D,L-lactic acid) were micropatterned to form grooves on the substrate surfaces. Laminin was localized in the grooves, and rat sciatic Schwann cells were seeded on the substrates. Whole as well as dissociated rat dorsal root ganglia were seeded on the substrates along with Schwann cells, and neurite outgrowth and alignment were measured. The micropatterns provide physical guidance, laminin provides chemical cues, and the Schwann cells provide biological cues to the axons. The presence of Schwann cells in the grooves was found to promote neurite alignment as well as outgrowth and help the neurites orient even on shallower grooves and exhibit continued alignment even as the grooves degrade. The synergistic combination of physical, chemical, and cellular guidance enabled greater than 98% alignment of neurites and accelerated outgrowth of neurites in the direction of the microgrooves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of Synapse Number by Glia
Ullian, E. M., Sapperstein, S. K., Christopherson, K. S., & Barres, B. A. (2001) · Science · doi:10.1126/science.291.5504.657 · Cited by 1,380
Chenn, A., & McConnell, S. K. (1995) · Cell · doi:10.1016/0092-8674(95)90035-7 · Cited by 766
Topographical control of cell behaviour: II. multiple grooved substrata
Clark, P., Connolly, P., Curtis, A. S. G., Dow, J. A. T., & Wilkinson, C. D. W. (1990) · Development · doi:10.1242/dev.108.4.635 · Cited by 682
Cited by
Neural Tissue Engineering: Strategies for Repair and Regeneration
Schmidt, C. E., & Leach, J. B. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.011303.120731 · Cited by 1,237
Fabrication of nano-structured porous PLLA scaffold intended for nerve tissue engineering
Yang, F., Murugan, R., Ramakrishna, S., Wang, X., Ma, Y.-X., & Wang, S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.062 · Cited by 604
The effect of the alignment of electrospun fibrous scaffolds on Schwann cell maturation
Chew, S. Y., Mi, R., Hoke, A., & Leong, K. W. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.10.025 · Cited by 521
Topography, Cell Response, and Nerve Regeneration
Hoffman-Kim, D., Mitchel, J. A., & Bellamkonda, R. V. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105351 · Cited by 516
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Engineering cell alignment in vitro
Li, Y., Huang, G., Zhang, X., Wang, L., Du, Y., Lu, T. J., & Xu, F. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.11.007 · Cited by 272
Recknor, J. B., Sakaguchi, D. S., & Mallapragada, S. K. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.029 · Cited by 254
Self-citationMicrofluidic alignment of collagen fibers for in vitro cell culture
Lee, P., Lin, R., Moon, J., & Lee, L. P. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-6380-z · Cited by 229
Simitzi, C., Ranella, A., & Stratakis, E. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.01.023 · Cited by 204
“Groove width was found to be a significant factor in promoting Schwann cell alignment, and widths and spacings ranging from 10to be optimal [116].”
BackgroundXie, J., MacEwan, M. R., Liu, W., Jesuraj, N., Li, X., Hunter, D., & Xia, Y. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5018557 · Cited by 162
Cell patterning with a heptagon acoustic tweezer – application in neurite guidance
Gesellchen, F., Bernassau, A. L., Déjardin, T., Cumming, D. R. S., & Riehle, M. O. (2014) · Lab Chip · doi:10.1039/c4lc00436a · Cited by 98
Microfluidic Systems for Neural Cell Studies
Babaliari, E., Ranella, A., & Stratakis, E. (2023) · Bioengineering · doi:10.3390/bioengineering10080902 · Cited by 13
Metadata
- Authors
- Miller, C., Jeftinija, S., & Mallapragada, S.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2001-12
- Volume
- 7
- Issue
- 6
- Pages
- 705-715
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2044301802
- Cited by
- 130
- References
- 3
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.