CoChat

Treatment of Osteochondral Defects with Autologous Bone Marrow in a Hyaluronan-Based Delivery Vehicle

Solchaga, Luis A., Gao, Jizong, Dennis, James E., Awadallah, Amad, Lundberg, Magnus, Caplan, Arnold I., Goldberg, Victor M. · 2002 · Tissue Engineering
Cited by 174

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

The natural repair of osteochondral defects can be enhanced with biocompatible, biodegradable and bioactive materials that provide structural support and molecular cuing to stimulate repair. Since bone marrow contains osteochondral progenitor cells and bioactive agents, it is hypothesized that the combination of scaffold and bone marrow would be a superior composite material for osteochondral repair. This hypothesis will be tested by comparing the outcome of osteochondral defects filled with a fibronectin-coated hyaluronan-based sponge (ACP) with or without autologous bone marrow. Thirty-three 4-month-old rabbits received 3-mm diameter osteochondral defects that were then filled with ACP loaded or not with autologous bone marrow. Rabbits were sacrificed at 2, 3, 4, 12, and 24 weeks after surgery and the condyles processed for histologic and immunohistochemical evaluation. The defects were graded with a histologic scoring scale. Except for the 3-week specimens, the histologic appearance of the defects was similar in both groups. Four weeks after surgery, the defects were filled with bone with a top layer of cartilage well integrated with the adjacent cartilage. Twelve and 24 weeks after surgery, the defects again showed bone filling. The primary difference between the 4-week samples and the 12- and 24-week samples was that the layer of cartilage that appeared to be thinner than the adjacent cartilage. At each harvest time, the overall histologic scores of the specimens did not reveal statistical differences between the treatment groups. However, as revealed by the results of the 3-week sacrifices, bone marrow loading appeared to accelerate the first stages of the repair process. The fibronectin-coated hyaluronan-based scaffold appears to organize the natural response and facilitate the integration of the neo-cartilage with the adjacent tissue. The fundamental tissue engineering principles derived from this study should provide guidelines for the development of comparable clinical reconstructive therapies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/107632702753725085

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 174

Metadata

Authors
Solchaga, L. A., Gao, J., Dennis, J. E., Awadallah, A., Lundberg, M., Caplan, A. I., & Goldberg, V. M.
Venue
Tissue Engineering
Published
2002-04
Volume
8
Issue
2
Pages
333-347
ISSN
  • 1076-3279 (ISSN-L)
  • 1557-8690
OpenAlex
W2177167308
Cited by
174
References
38
FWCI
10.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.