Long-Term Culture of Functional Liver Tissue: Three-Dimensional Coculture of Primary Hepatocytes and Stellate Cells
The DOI matches its Crossref record.
Abstract
One of the greatest challenges in the attempt to create functional liver tissue in vitro is the maintenance of hepatocyte-specific functions. The pharmaceutical industry has long awaited the development of engineered liver tissue, which could represent a long-term, inducible, high-fidelity model for high-throughput screening of new drug compounds. It is also anticipated that such engineered models could one day be used in liver transplants, where replacement is limited by chronic donor shortages. As isolated hepatocytes dedifferentiate rapidly in culture the use of hepatocytes in long-term studies has proved to be a difficult challenge. Here we report a system of rat hepatocytes cocultured with primary rat hepatic stellate cells on a biodegradable poly(DL-lactic acid) substratum. These coculture conditions were found to encourage the rapid self-organization of three-dimensional spheroids. The spheroids formed exhibit hepatocyte-specific functionality (CYP-450 activity and albumin secretion) after almost 2 months in static culture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Advances in the formation, use and understanding of multi-cellular spheroids
Achilli, T.-M., Meyer, J., & Morgan, J. R. (2012) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2012.707181 · Cited by 572
In vitro models for liver toxicity testing
Soldatow, V. Y., LeCluyse, E. L., Griffith, L. G., & Rusyn, I. (2013) · Toxicol. Res. · doi:10.1039/c2tx20051a · Cited by 472
A Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Generation of Three-Dimensional Hepatocyte/Gelatin Structures with Rapid Prototyping System
Wang, X., Yan, Y., Pan, Y., Xiong, Z., Liu, H., Cheng, J., Liu, F., Lin, F., Wu, R., Zhang, R., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.83 · Cited by 353
Fabrication of viable tissue-engineered constructs with 3D cell-assembly technique
Yan, Y., Wang, X., Pan, Y., Liu, H., Cheng, J., Xiong, Z., Lin, F., Wu, R., Zhang, R., & Lu, Q. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.027 · Cited by 284
Self-Organization and the Self-Assembling Process in Tissue Engineering
Athanasiou, K. A., Eswaramoorthy, R., Hadidi, P., & Hu, J. C. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152423 · Cited by 225
Decellularization for whole organ bioengineering
Arenas-Herrera, J. E., Ko, I. K., Atala, A., & Yoo, J. J. (2013) · Biomedical Materials · doi:10.1088/1748-6041/8/1/014106 · Cited by 221
Galactose-carrying polymers as extracellular matrices for liver tissue engineering
Cho, C. S., Seo, S. J., Park, I. K., Kim, S. H., Kim, T. H., Hoshiba, T., Harada, I., & Akaike, T. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.06.008 · Cited by 174
Method for the decellularization of intact rat liver
Shupe, T., Williams, M., Brown, A., Willenberg, B., & Petersen, B. E. (2010) · Organogenesis · doi:10.4161/org.6.2.11546 · Cited by 173
“While this concept may seem straight forward, complications in maintaining functional hepatocytes in three-dimensional culture have limited the development of these systems.(3-6) Synthetic matrices have proven to be sub-optimal in regards to both the extent of colonization as well as the long term maintenance of cell…”
BackgroundVascularized microfluidic organ-chips for drug screening, disease models and tissue engineering
Osaki, T., Sivathanu, V., & Kamm, R. D. (2018) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2018.03.011 · Cited by 141
“To further extend the lifetime of liver advanced metabolism in vitro [46], vascularization of liver spheroids and perfusion into micro-tissues are still needed.”
Hydrogels for Liver Tissue Engineering
Ye, S., Boeter, J. W. B., Penning, L. C., Spee, B., & Schneeberger, K. (2019) · Bioengineering · doi:10.3390/bioengineering6030059 · Cited by 112
Micropatterns of Matrigel for three-dimensional epithelial cultures
Sodunke, T. R., Turner, K. K., Caldwell, S. A., McBride, K. W., Reginato, M. J., & Noh, H. “. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.05.021 · Cited by 109
Primary Hepatocyte Isolation and Cultures: Technical Aspects, Challenges and Advancements
Kaur, I., Vasudevan, A., Rawal, P., Tripathi, D. M., Ramakrishna, S., Kaur, S., & Sarin, S. K. (2023) · Bioengineering · doi:10.3390/bioengineering10020131 · Cited by 64
Metadata
- Authors
- Riccalton-Banks, L., Liew, C., Bhandari, R., Fry, J., & Shakesheff, K.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2003-06
- Volume
- 9
- Issue
- 3
- Pages
- 401-410
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2159396437
- Cited by
- 122
- References
- 0
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.